When using the supplied AC cord ..................26 Connecting video cables to Wireless Transmitter ..........27 Selection of video input terminal ..................27 Connection diagram (When using HD-SDI) ................. 28 Connection diagram (When using DVI) ................29 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 4
System chart ........................43 FCC (for Wireless Transmitter and Receiver) ..............45 FCC/IC (for Wireless Transmitter and Receiver) ............45 Specifications ........................46 Environment ........................46 Specifications ........................48 EMC information ......................50 FCC WARNING ......................... 54 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Labels and Symbols Labels and Symbols Safety-related labels and symbols are attached on the locations shown below. If labels or symbols are missing or illegible, contact Olympus. Wireless Transmitter CSA/UL marking Potential equalization terminal Serial number plate This instrument emits RF (Radio Frequency) energy to perform intended functions.
Page 6
AC Adaptor Electric rating The product name, rated voltage, and notice for AC adapter are shown OLYMPUS AC Adapter Model Name: OLP-K027-M INPUT : 100–240 V 1–0.5 A, 50/60 Hz OUTPUT 12 V 1.3 A Manufacturer name UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 7
Labels and Symbols Back cover of this instruction manual Symbol Description Manufacturer Authorized representative in the European Community UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Intended use The Olympus Wireless Image Transmitter Unit UWIT-Y0001 is a paired transmitter and receiver, intended for delivery of video signals over a radio-frequency link to a video display during endoscopic and general surgical procedures. The Olympus UWIT-Y0001 is a non-sterile reusable device not intended for use in the sterile field.
Some problems that appear to be malfunctions may be correctable by referring to Chapter 7, “Troubleshooting”. If the problem cannot be resolved using the information in Chapter 7, contact Olympus. This instrument is to be repaired by Olympus technicians only.
Oxidizing agents (such as nitrous oxide (N O)) are present in the atmosphere; Flammable gases are present in the atmosphere; Flammable liquids are near. Otherwise, explosion or fire may result because this Wireless Image Transmitter Unit is not explosion-proof. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 11
• Do not touch the electrical contacts inside the Wireless Image Transmitter Unit’s connectors. • Do not apply excessive force to this Wireless Image Transmitter Unit and/or other instruments connected. Otherwise, damage and/or malfunction can occur. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
60.48 GHz (When using CH1) 62.64 GHz (When using CH2) Frequency range of 59.40 – 61.56 GHz (When using CH1) possible interference 61.56 – 63.72 GHz (When using CH2) Modulation method OFDM High-frequency Less than +40 dBm output UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Pair changing function By using the SELECT button of the Wireless Transmitter and Receiver, the Channel (CH1 or CH2) for pairing Transmitter and Receiver can be set manually. oSee Section 5.2, “Connection of the Wireless Transmitter and Receiver”. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 14
Summary of Equipment Functions UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Match all items in the package with the components shown below. Inspect each item for damage. If the Wireless Image Transmitter Unit is damaged, a component is missing, or you have any questions, do not use the Wireless Image Transmitter Unit; immediately contact Olympus. ...
Page 16
1.1 Checking the package contents Wireless Receiver Ch.1 Wireless Receiver (UWIT-Y0001-RX) AC adaptor AC cord DVI cable (MAJ-1945) Access sheet UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 17
1.1 Checking the package contents Optional equipment The following products are optional Olympus products that may be purchased separately. Attachment for UWIT (MAJ-Y0149) Ch.1 Attachment for UWIT Screw (for installing UWIT-Y0001-TX Screw (for installing OEV261H) (MAJ-Y0149) or UWIT-Y0001-RX) (2 pcs.) (4 pcs.)
Chapter 2 Nomenclature and Functions The instrument nomenclature, functions, and specifications are described in this chapter. Symbols and descriptions Ch.2 Front panel Symbol Description Select Rear panel Symbol Description Serial number Potential equalization terminal UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Selected video input selection (SDI or DVI) will have a steady light or blink. It will have a status display steady light when the Wireless Transmitter detects supported video format, and it will blink when the Wireless Transmitter cannot detect any video signal or unsupported video format is detected. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Rear panel of Wireless Transmitter Ch.2 Nomenclature Description HD-SDI IN terminal Inputs HD-SDI video signal. DC IN terminal This is the 12V DC input terminal. Connect the supplied AC adaptor to this terminal. DVI IN terminal Inputs digital video signal. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Rear panel of Wireless Receiver Nomenclature Description DC IN terminal This is the 12V DC input terminal. Connect the supplied AC adaptor to this terminal. DVI OUT terminal Outputs digital video signal. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
2.6 AC adapter AC adapter Ch.2 Nomenclature Description AC IN terminal This is the AC input terminal. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 24
2.6 AC adapter Ch.2 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
• The cables should not be sharply bent, pulled, twisted or crushed. Cable damage can result. • Use this instrument only under the conditions described in “ Environment” on page 46 and “ Specifications” on page 48. Otherwise, improper performance, compromised safety and/or equipment damage may result. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Align the mounting screw holes on the rear of the Wireless Transmitter or Receiver with the mounting screw holes on the Attachment for UWIT. UWIT-Y0001-TX UWIT-Y0001-RX Figure 3.2 Fix the Wireless Transmitter or Receiver onto the Attachment for UWIT using two screws provide with the Attachment for UWIT. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 27
OEV261H which is on the ceiling arm, ensure that there is no mechanical interference with other moving part of the ceiling arm/pendant. • Check if the unit is intended to install by referring to front or rear panel of the Wireless Transmitter or Receiver before the installation. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Installation on the Attachment for UWIT (MAJ-Y0149) Ch.3 Fix the AC adaptor to the Attachment for UWIT using the attachment for AC adapter provided with the Attachment for UWIT. Figure 3.3 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Connect the power cord to the AC IN terminal on the AC adaptor. Ch.3 Figure 3.4 Insert the DC cord into the DC IN terminal on the Wireless Transmitter or Receiver. Fix DC cord by winding finger screw. Figure 3.5 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Power cord of the mobile workstation Figure 3.6 Connect the power cord of the mobile workstation to wall mains outlet. When using the supplied AC cord Connect supplied AC cord to wall mains outlet. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
1 second, however, continue to hold the SELECT button. Release the finger after confirm that the selection of SDI or DVI is completed in the video selection status display. The one selected blinks or lights on and the other unselected lights off. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
HD-SDI video signal of HD-SDI IN terminal from such as video system center. Select HD-SDI output in the video output selection of the video system center. The Wireless Transmitter doesn’t support SD-SDI. Do not select SD-SDI in the video output selection. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
• Select 1080p in the video output selection of the video system center. Do not select the resolutions such as WUXGA in the video output selection that the Wireless Transmitter doesn’t support. • Connect the video system center and OEV261H directly by video cable such as SDI cable (MAJ-1912, MAJ-1464, MAJ-1951). UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Connecting video cables to Wireless Receiver Connection diagram UWIT-Y0001-RX Ch.3 MAJ-1945 OEV261H Figure 3.9 CAUTION Ensure that the Wireless Receiver is fixed firmly to the DVI-D IN terminal of the high definition LCD monitor OEV261H. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Wireless image transmitter unit and see Chapter 7, Ch.4 “Troubleshooting”. If the irregularity is still observed after consulting Chapter 7, contact Olympus. Damage or irregularity may compromise patient or user safety and may result in more severe equipment damage. Inspection of the power supply Power indicator lights on when the Wireless Transmitter or Receiver is powered.
Do not place the Wireless Transmitter or Receiver in different direction such as to the ceiling or the floor because the RF path may become insufficient to stabilize the Wireless Transmitter. Do not set either one of the Wireless Transmitter or Receiver upright. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 37
Turn on the Wireless Transmitter, Receiver and peripheral devices and confirm the image is displayed on the monitor which is connected to the Wireless Receiver. Confirm that the endoscopic image is normal by observing any object such as the palm of your hand. Ch.4 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 38
4.2 Inspection of the displayed image Ch.4 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Connect the AC cord of the Wireless Transmitter or Receiver to the wall mains outlet. CAUTION After using the Wireless Transmitter or Receiver, disconnect the AC cord from the wall mains outlet or from the AC adaptor. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
The CH light will blink during the connection process. The CH light will be steady once the Wireless Transmitter and Receiver are connected. If CH light continues to blink and connection cannot be established, please refer to Chapter 7, “Troubleshooting”. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Remove dust, dirt, and other stains on the surface by wiping with a piece of gauze moistened with 70% ethyl or isopropyl alcohol. Make sure to dry the Wireless Image Transmitter Unit after wiping with 70% ethyl or isopropyl alcohol. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Store the equipment in the level position in a clean, dry, and stable location. Disposal Ch.6 When disposing of this instrument or any of its components (such as fuses), follow all applicable national and local laws and guidelines. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Never use the Wireless Image Transmitter Unit if an irregularity is observed. Damage or irregularity of the Wireless Image Transmitter Unit may compromise patient or user safety and may result in more severe equipment damage. Ch.7 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Troubles or failures other than those listed in the following table need repair. If repair is performed by persons who are not qualified by Olympus, patient or user injury and/or equipment damage may result. Be sure to contact Olympus for repair.
Page 45
Wireless Receiver off, wait 10 seconds or more Transmitter or Receiver. and turn on again. If the irregularity cannot be solved, contact Olympus. The Wireless Transmitter or This symptom may be caused by a Turn the Wireless Transmitter or...
Returning the Wireless Image Transmitter Unit for repair CAUTION Olympus is not liable for any injury or damage which occurs as a result of repairs attempted by non-Olympus personnel. When returning the Wireless Image Transmitter Unit for repair, contact Olympus. With the Wireless Image Transmitter Unit, include a description of the malfunction or damage and the name and telephone number of the individual at your location who is most familiar with the problem.
The recommended combinations of equipment that can be used with this Wireless Image Transmitter Unit are listed below. New products released after the introduction of the Wireless Image Transmitter Unit may also be compatible for use in combination with it. For further details, contact Olympus. WARNING If combinations of equipment other than those shown below are used, the full responsibility should be assumed by the medical treatment facility.
Page 48
Image management HUB WM-DP1) (IMH-10) VISERA ELITE video system center (OTV-S190) EVIS EXCERA III video system center (CV-190) Image management HUB (IMH-20) Color video printer (OEP-5) * These products enclosed with the dotted line conform to EMC (Ed.3) UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
évaluation de l’exposition maximale autorisée. Cependant, cet équipement doit être installé et utilisé en gardant une distance de 20 cm ou plus entre le dispositif rayonnant et le corps (à l’exception des extrémités: mains, poignets, pieds et chevilles). UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
30 – 85% (without condensation) Atmospheric 700 – 1060 hPa pressure Usage location Indoor use only Transportation and Ambient temperature –25 to +70qC (–13 to +158qF) storage environment Relative humidity 10 – 90% Atmospheric 700 – 1060 hPa pressure App. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 51
In that case, confirm before use that no interference from neighboring rooms by using different Channels in neighboring rooms as shown below. If interference still occurs, consider installing the Wireless Image Transmitter App. Unit in alternating rooms (every other room). UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 53
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. App. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
App. to this instrument. Voltage Complies This instrument stabilizes its own radio variability and has no effect fluctuations/flicker such as flicker in lighting apparatus. emissions IEC 61000-3-3 UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 55
It is recommended to use this instrument by (50/60 Hz) maintaining enough distance from any magnetic field equipment that operates with high current. IEC 61000-4-8 NOTE is the AC mains power supply prior to application of the test level. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 56
• Electromagnetic interference may occur on this instrument near a high-frequency electrosurgical equipment and/or other equipment marked with the following symbol: The word “Transmitter” is generic term used for conventional portable and mobile RF communication equipment such as cellular phones. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Page 57
App. frequency of the transmitter The word “Transmitter” is generic term used for conventional portable and mobile RF communication equipment such as cellular phones. UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL...
Subpart B of Part 15 of FCC Rules. Declaration of Conformity Trade Name: OLYMPUS MEDICAL SYSTEMS Model: UWIT-Y0001-TX, UWIT-Y0001-RX Responsible Party: OLYMPUS AMERICA INC.