D01B-30A-UK1 January 2017 Instructions for SILEX 1C Mixed bed cartridge filter With conductivity sensor Gravity flow or pressure installation SILHORKO-EUROWATER A/S Phone +45 86 57 12 22 DK-8660 Skanderborg info@eurowater.com Denmark www.eurowater.com...
Page 2
We offer customized service agreements, high quality consumables and modernizations. In order to keep your critical systems running EUROWATER offer call-out service for urgent needs, individual service agreement on preventive maintenance, access to high-quality spare parts and consumables as well as modernizations in all shapes and sizes.
Instructions SILEX 1C D01B-30A-UK1 January 2017 Contents 1. Introduction ..............................4 1.1. List of figures ............................4 2. General information............................. 4 2.1. Plant description ............................. 4 2.2. Quality requirements of the untreated water ..................4 2.3. The contents of dissolved salts in the water - conductivity ..............4 2.4.
Instructions SILEX 1C D01B-30A-UK1 January 2017 1. Introduction The instructions are made so that they can be followed section by section. It is recommended to follow the instructions carefully since any service calls due to faulty installation, plant start, operation or insufficient maintenance are not covered by our guarantee.
Instructions SILEX 1C D01B-30A-UK1 January 2017 3. Installation instructions 3.1. Gravity flow installation 1. Use the angle fittings supplied to mount the SILEX plant on the wall close to a stop valve. The water feed to the plant is regulated with the stop valve (pos. 1) 2.
Instructions SILEX 1C D01B-30A-UK1 January 2017 3.2. Pressure installation 1. Mount the SILEX plant on the wall with the fittings supplied. 2. The plant is designed for a maximum pressure of 6 bar. Exceeding the maximum operating pressure of the plant can cause reflux in the installation or temperature increase in the liquid during a standstill.
Instructions SILEX 1C D01B-30A-UK1 January 2017 4. Conductivity meter The electronic conductivity meter continuously measures and displays the quality of the demineralized water. 4.1. Secon V3-10 The water quality is expressed as the water's capability of conducting an electric current and the conductivity is measured in µS/cm.
When the system or parts thereof are no longer in use, they must be disposed of through approved public or private systems, in accordance with environmental regulations. When in doubt, please contact your local EUROWATER office or distributor. Page 8 | 9...
January 2017 7. Consumables and selected spare parts EUROWATER plants last for many years, but consumables, such as filter media, salt for regeneration, ion exchange resin and filters, have a certain capacity or lifespan and must be replaced at certain intervals.