INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN
Important: Read all instructions and refer to local codes
prior to installation.
Local soil conditions may require more gravel for
l
drainage.
It is recommended to include a supply stop
l
appropriately located on the supply line.
An in-line PRV installed on the supply line is
l
recommended to ensure a working water pressure of 40-
60 psi.
A water filter should be installed on the supply line if
l
sediment or mineral content is a problem.
Provide 30" x 30" x 6" deep concrete pad minimum.
l
Prepare trench for water supply line and waste line (if
required). At fountain location prepare hole to trench depth
and large enough for a person to work. Lay supply and
waste into trench allowing extra length to be trimmed
during hook-up.
Depending on code and design requirements, drain may
be open, French or sanitary connection. For French drain,
place a minimum of three cubic feet of gravel under drain
opening. Local soil conditions may require more gravel
drainage.
Refill trench and hole, compacting back fill as required.
Leave sufficient depth in hole to accommodate concrete
pour.
MOUNTING BASE DETAIL
7
7
"
8
TYP
Ø6"
BUBBLER
ORIENTATION
Please visit www.murdock.com
for most current specifications.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
9938-159-M01
CONTEMPORARY DRINKING FOUNTAINS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
9
Ø
"
16
Ø13"
1
Ø11
"
8
PUSHBUTTON
ORIENTATION
Page 1 of 3
WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Prepare the slab area surrounding fountain spreading and
compacting gravel as necessary. Prepare form
approximately 6" diameter to protect supply and waste
stub outs.
If required, fix 1/4"-20 UNC L-bolt anchors by others in
position arranging L-bolts according to pattern indicated
and pour concrete to grade. Leave enough thread for
mounting base. Ensure concrete top surface is flat and
level. If concrete has cured use appropriate ½" concrete
anchoring hardware by others following the manufacturer's
installation recommendations.
For freeze resistant option refer to
-FRU manual #9938-340-0M1.
3
" OD x 4" LONG
8
COPPER TUBE
4"
4"
GRAVEL
EARTH
2" PVC DWV
RECOMMENDED
GRAVEL
MINIMUM 3 CUBIC FEET OF
POROUS GRAVEL FILL
Valve Specifications:
Minimum/Maximum Pressure:
30/100 PSI
30" x 30" x 6" DEEP
MIN. CONCRETE PAD
`
FROST LINE
WATER
SUPPLY