Limited Warranty & Limitation of Liability BW Technologies Ltd. (BW) warrants this product to be free from defects in material and workmanship under normal use and service for a period of two years, beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to the original buyer.
Page 3
MicroDock Introduction This Quick Reference Guide provides basic user instructions for the MicroDock. Refer to the User Manual on the accompanying CD-ROM for complete operating instructions. The MicroDock Automatic Test and Calibration Station (“the Station”) provides automated calibration and bump testing for the GasAlertMicro multi-gas detector.
The maximum recommended vent line length is 50 feet. a Cautions ⇒ If the Station is damaged or something is missing, contact BW Technologies immediately. ⇒ We recommend that the Station be attached to a venting system or that the Station be used in a well-ventilated area.
MicroDock Parts of the MicroDock Parts of the MicroDock Item Function LCD display Zero air inlet (inlet 1) Calibration gas inlet (inlet 2) Activation buttons Base station Power connection USB connection Battery cover Docking module lid Vent outlet Detector bay...
MicroDock Quick Reference Guide Display Elements Pushbuttons Icon Function Pushbutton Description • To bump a detector, press BUMP Alternating current CHECK C. Batteries full • When connecting a new Docking Batteries half-charged Module press and hold BUMP BUMP CHECK CHECK C to send a confirmation Batteries depleted signal back to the Base Station.
1 on the Station. Plug the Station into a VAC outlet or refer to the Battery Installation section for battery installation instructions. Refer to Appendix A in the MicroDock User Manual for PC software installation and user instructions. Item...
MicroDock Quick Reference Guide Battery Installation Follow these steps to install the batteries in the Station. Loosen, but do not remove the retaining screws from the battery cover. Remove the battery cover and set it aside. Insert four C-cell batteries into the battery compartment.
Station while it is not in use. Note: If the MicroDock is placed into sleep mode, approximately 10 seconds later the detector turns off. The batteries are tested on activation and continuously after. If...
Page 10
MicroDock Quick Reference Guide Activate the detector and wait until it is in normal operating mode. Note: Ensure the detector is not in a low battery state. Note: Rotate the alligator clip ring on the GasAlertMicro so it Note: To bypass the station identification screen, press any C fits into the groove located on the Docking Module.
Page 11
MicroDock Inserting a Detector into a Docking Module Item Description Alligator clip ring Docking Module lid Release tabs Detector bay...
LEDs. Once the first module is • Calibration accuracy is never better than the calibration gas complete, the next module in the queue will activate the accuracy. BW Technologies recommends a premium-grade applicable test. calibration gas. Gases with NIST (National Institute of...
If an audible or visual test displayed beside the fails, will be displayed applicable test. Refer to the beside the applicable test. Troubleshooting section in Refer to the Troubleshooting the MicroDock User Manual. section in the MicroDock User Manual.
Connect to PC removable multimediacard (MMC). Saved tests can be Time/Date uploaded to a PC from the Contrast Station. Refer to Appendix A in the MicroDock User Backlight Manual for PC software installation and user Gas Inlets instructions. About Pump Set up...
• Confirm that the inlet filter is free of dirt and replace it if necessary. To order replacement parts, see the section The Station is shipped with “Replacement Parts and Accessories” in the MicroDock English as the displayed User Manual.
Quick Reference Guide Alarm/Calibration Parameters: Specifications User-settable Calibration Gas Connections: Built-in (Base Station) The MicroDock is used for general purposes only. Gas Connection: 1/8″ SMC connect sub-miniature coupling Operating Temperature: +10 to +45 °C (50 to +113 ºF) Solenoid: Built-in (Docking Modules) Storage Temperature: -10 to +60 °C (14 to 140 ºF)
Need help?
Do you have a question about the MicroDock and is the answer not in the manual?
Questions and answers