XPD0215SL User’s Manual Power Distribution Unit Table of Contents System Description..................4 Front and Back Panel........................5 Important Safety Precautions for Hardware Installation.......6 Safety Precautions..................6 Battery Replacement........................7 Access to the System..................7 Factory Default Settings........................7 User Privileges and Port Reservations.....................8 Local Master Port Access.........................8 External Modem Access........................8...
Page 3
XPD0215SL User’s Manual Power Distribution Unit FCC Warning The Federal Communications Commission has set limits for emitted radio interference. Shanghai Qianjin Networks systems are constructed with this electromagnetic interference (EMI) limitation. The systems are classified as a Class A and Class B under FCC Regulations . The Class A device is suggested to be used in commercial environments instead of residential areas, The Class B device may be used in residential areas.
XPD0215SL User’s Manual Power Distribution Unit System Description Item XPD0215SL Enter Plug Supply Plug NEMA5-15P NEMA5-20P CEE7/7 IEC60309 Equipment End IEC60320-C14 Outlets (2)NEMA5-15 Input current 15-20 Amp Input Voltage 100-240 VAC Chassis (W x D x H) 6.0 x 6.7 x 1.75 in Console Port Baud rate:115200;...
XPD0215SL User’s Manual Power Distribution Unit What you can do with the system: • Remote equipment power source management over TCP/IP networks, including user equipment reboot- ing, and permanently user power source turn on/off. Schedule power reboots or power source on/off events monthly, weekly, daily or at any time.
XPD0215SL User’s Manual Power Distribution Unit Back Panel 1: Power Outlet status LED: Visual indication of user power outlet On/Off status. 2: System power On/Off status LED: Indication of system power On/Off status. 3: Ethernet Link status LED: When the LED is illuminated, Ethernet port and a LAN connection are established.
XPD0215SL User’s Manual Power Distribution Unit WARNING! To be safe, the unit must has the ground protection. Battery Replacement A 3.0V Lithium recharging battery is installed in the unit for internal Real-Time Clock and system data retention. The battery should last recharging 1000,000 times at least. If the battery needs to be replaced, please ask autho- rized service personnel to do so.
XPD0215SL User’s Manual Power Distribution Unit User Privileges and Port Reservations All user levels, including anonymous (visitor), are able to access the system via a serial connection from your work station to the Local Master port, or via a Telnet session from your work station.
XPD0215SL User’s Manual Power Distribution Unit Before you start the Telnet application, the user need to obtain the actual IP address for the system. The system displays network connectivity information at system startup terminal when your workstation is connected to the system’s Local Master Serial Port.
XPD0215SL User’s Manual Power Distribution Unit Web Access Startup Page Upon clicking the Login button, a secured login table is displayed at you work station. Factory default setting for user name is “admin”. The default password is “admin”. Web Access Login Entry Table Email Access To establish this access method, the system’s network connection is already established.
XPD0215SL User’s Manual Power Distribution Unit Sending Command from Hotmail Web Site SNMP Information Applications such as an NMS (Network Management System) or an SNMP browser can exchange information with the NP systems. SNMP is disabled with the default setting.
XPD0215SL User’s Manual Power Distribution Unit Enterprise OID: 1.3.6.1.4.1. 32287 Definition Returned message devName .1.1 The system name or site name. Read only. devType .1.2 The system model type. Read only. First AC current monitoring reading. For a system equipped with single power cord, sysCurrentA .1.3...
Page 13
XPD0215SL User’s Manual Power Distribution Unit ************************************************************ Help Menu ************************************************************ **NOTE : command marked with * need user permission **NOTE : command marked with # need admin permission login login logout logout whoami who am i? show userlist show the hw/sw version...
XPD0215SL User’s Manual Power Distribution Unit Using Configuration Menu Starting Configuration Menu There are four ways to start the Configuration Menu: 1. Local Master Port access method. The user run a terminal program from a work station and Local Master Port of the system via serial connections between a serial port .
Page 15
XPD0215SL User’s Manual Power Distribution Unit Power Outlet Setup Menu (Web Page) Name: Define a name for the power outlet. On/Off: Set the power outlet to power on or off state. Reservation: Reserve the port for special user. AutoPing and reboot (Power reboot If user equipment’s network is down) Disable or enable AutoPing power reboot function.
XPD0215SL User’s Manual Power Distribution Unit Helpful Info: Use command “pshow” to display all power outlet status. ************************************************************ Power Outlet Port Parameters and Status ************************************************************ > > Port | Name | status | Reserved By | Timer | AutoPing ------+-----------------+----------+-----------------+---------|-------------...
Page 17
XPD0215SL User’s Manual Power Distribution Unit ur:minute:second”. For example, to start changing the power outlet on/off state at 7:17:27pm, on July 20th 2008, the entry data is 08:07:20:19:17:27. Timer Period: Specify the timer period. It is in the format of “days:hours:minutes:seconds”, which is not a calendar and real-time clock entry type.
XPD0215SL User’s Manual Power Distribution Unit 3) Reboot once on a specific date and time: Current Calendar date and time are: Aug. 10th,2008, 10:00 am. To schedule a reboot on Feb 12th, 1:00 am. Timer Start Time = 09:02:12:1:00:00 - Start the event at 1:00am,2009, on Feb. 12th, Timer Period = 6 - 6 seconds Timer Toggle Duration = 5 - 5 seconds.
XPD0215SL User’s Manual Power Distribution Unit System Access Setup Menu System Access Control Menu (Web Page) System(or Site) name: Assign a system name, sometimes referred as site or device name. Date and Time: Enter calendar date and real-time clock. Serial Port Mode: Configure the Local Master Port to interface type: either to a serial RS-232 port on your work station or an external Modem device.
XPD0215SL User’s Manual Power Distribution Unit Telnet Access: Enable or disable Telnet access to the system. Default to enable. Only one active Telnet session is permissible. Enable Telnet Anonymous User: Enable or disable an anonymous user’s access to Telnet port.
Page 21
XPD0215SL User’s Manual Power Distribution Unit Baud Rate: The system supports the following baud rates: 2400, 4800, 9600, 19200, 38400, 57600 and 115200. It is strongly recommended that Master port and a user serial port have the same data rate while exchang- ing data between them so that data loss is eliminated.
XPD0215SL User’s Manual Power Distribution Unit TCP/IP Network Configuration Menu TCP/IP Network Configuration Menu (Web Page) Obtain IP using DHCP: Enable or disable DHCP. The purpose of using DHCP (Dynamic Host Configuration Protocol) is to assign dynamic IP addresses to a computer or a network device on a network. There must be a DHCP server on a network running and the server must permit an assigned computer or network device to be on the LAN.
Page 23
XPD0215SL User’s Manual Power Distribution Unit Fallback to static IP (if DHCP failed): Define a static IP address. If DHCP is disabled on the system, there is no DHCP server running on a network, or a DHCP server refuses IP offering, you have the option to whether either allow the system to use a static IP address or not.
XPD0215SL User’s Manual Power Distribution Unit Account Name: Specifies email address that the system receives. This email account name is also used for outgoing (replying) emails. Account Password: The Email account password is specified in this entry. This password is also used for outgoing (replying) emails.
XPD0215SL User’s Manual Power Distribution Unit Caution: • If using a static IP address, after config ip, netmask and gateway, you must run command “ifconfig static” to enable static IP address. • f using DNS fuction(e.g. set pop3 server), you must set DNS server IP address manually.