Do you have a question about the PC5000 and is the answer not in the manual?
Questions and answers
Summary of Contents for Dixon Bayco PC5000
Page 1
Instructions Dixon Bayco PC5000 Inline High Pressure Air Filtration for 4" Air Lines For Sales and Service Contact USA: Canada: Dixon Bayco USA Dixon Group Canada Limited Chestertown, Maryland Innisfil (Barrie), Ontario Phone: 410-778-2000 Phone: 705-436-1125 Fax: 410-778-4702 Fax: 705-436-6251...
Page 2
The following inspection procedure must be implemented in order for the product warranty to be in effect. Any change or deviation from this procedure voids the Dixon Bayco product warranty and removes Dixon Bayco from any contamination liability. Remove quick disconnect V-clamp and remove end cap.
Page 3
PC5000 Inline High Pressure Air Filtration 9. Inspect lid O-ring and replace if damaged. 10. Loosen adjustments bolt, replace lid and clamp ring. Tighten clamp ring. Tighten adjusting bolt and lock nut. Replace acorn nut. Do not service this filter canister while under pressure! We recommend maintaining a filtration inspection log book in establishing a replacement schedule that is optimal for your fleet.
Page 4
PC5000 Inline High Pressure Air Filtration There are two primary places PneuClean filtration units can be mounted, on the road tractor or on the dry bulk trailer Tractor When mounting PneuClean on the tractor, the units can be mounted either horizontally or vertically this application offers an added benefit that the filter unit will act as a silencer if mounted within 24"...