Orbeco HELLIGE SC400 Instruction Manual

Chlorine fluoride colorimeter

Advertisement

Quick Links

SC400 Colorimeter
Fluoride
Instruction Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC400 and is the answer not in the manual?

Questions and answers

Dave Ghosn
March 5, 2025

where can we get a new glass vial? ours broke. Thanks.

1 comments:
Mr. Anderson
May 14, 2025

You can find a replacement glass vial for the Orbeco HELLIGE SC400 under the product listings for Orbeco-Hellige (now Lovibond) optical glass cells. These include items such as the W565/OG/100ML colorimeter cell, which may be compatible with the SC400. Replacement parts are available by custom quotation from vendors offering Orbeco-Hellige products.

This answer is automatically generated

Summary of Contents for Orbeco HELLIGE SC400

  • Page 1 SC400 Colorimeter Fluoride Instruction Manual...
  • Page 2: Operation

    Operation Switch the unit on using the ON/OFF key. The display shows the following: Fill a clean vial with the water sample up to the 10 mL mark, screw the cap on and place in the sample chamber with the ∆-mark on the vial aligned with the ∇−mark on the instrument.
  • Page 3: Technical Data

    Technical Data Light source: LED, Filter (l = 580 nm) Battery: 9 V-block battery (Life 600 tests), without display light. Auto-OFF: Automatic switch off 5 minutes after last keypress Ambient conditions: 5-40°C 30 - 90 % rel. humidity (non-condensing). DIN EN 55 022, 61 000-4-2, 61 000-4-8, 50 082-2, 50 081-1, DIN V ENV 50 140, 50 204 Method notes Prior to measurement ensure that the sample is suitable for analysis...
  • Page 4 – Fluoride 0.05 - 2.0 mg/L F Perform zero calibration (see "Operation") 0.0.0 Add accuratly 2 mL of SPADNS-reagent to the 10 mL water sample. (Attention: vial is filled to the top). Replace the cap tightly. Invert the vial gently several times to mix the contents.
  • Page 5: Menu Selections

    Menu selections Press the MODE key and hold. Mode Switch the unit on using the ON/OFF key. Allow the 3 decimal points to be displayed before releasing the MODE key. The “!” key allows for selection of the following menu points: ▲...
  • Page 6: Calibration Mode

    Calibration Mode Note: A new calibration is necessary in case of a new unit as well as by use of a new BATCH of SPADNS reagent solution. Press MODE key and hold. Mode Switch unit on using ON/OFF key. Release MODE key after approx. 1 second. The “!”...
  • Page 7: Error Codes

    Error codes not available at the moment in case of technical reqirements. Changing the battery...
  • Page 12 Orbeco-Hellige Inc., 185 Marine Street, Farmingdale, NY 11735 Phone: 631-293-4110, Fax: 631-293-8258, service@orbeco.com, www.orbeco.com...