3.6 DIAGNOSTICS MENU 3.7 OTHER DISPLAYS MENU 3.8 FLOWRATE- TOTALIZERS MENU ANALYSIS 3.9 INITIAL SETTING MENU ANALYSIS 3.10 FLOWRATE UNITS MENU ANALYSIS B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 3
6.2 SOUND SPEEDS IN FLUIDS 6.3 SOUND SPEEDS IN WATER AT SELECTED TEMPERATURES 6.4 PIPE SIZE DATA 7. EC- DECLARATION OF CONFORMITY B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 4
AND MUST CORRESPOND EACH OTHER. 2. THE DEVICE IS SUPPLIED WITH UNCHARGED BATTERIES. PLS CHARGE THE BATTERIES FOR 12 HOURS BEFORE USING THE DEVICE. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
• RS232 output. • All the measures could be driven to the RS232 in order to save data into a PC or a serial printer. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
• EC certification 1 pc • Instruction Manual 1 pc * depending from the type of sensors ordered by the customer B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
It is very important to select the right measuring point. The fluid has to be a measurable fluid and the pipe should be suitable for this measuring technology. Do not hesitate to contact B.M. TECNOLOGIE INDUSTRIALI for any further clarification. Please proceed as follows: 1) Select the measuring point on the pipe, in order to have a fluid free from turbulences.
6) Transducers type. 7) Transducers mounting method (V, Z, N, W method). In M25 menu it is possible to see the right mounting distance between the transducers. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
F l o w 0 . 0 0 0 0 m 3 / h W i n d o w N o . B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
The device calculates the value based on the entered settings. It is possible to press again and the device will display the parameters it calculated until now. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 14
The standard sensors are Clamp-on TM1 type, for pipes from DN50 up to DN1000. It is possible to ask for different sensors, depending from the application. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 15
S a v e / L o a d p a r a m e t e r s > > E n t r y t o S A V E B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 16
0 . 0 0 0 0 m 3 / h N o S i g n a l D e t e c t e d Now it is possible to install the transducers. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
In order to install the sensors, check if the pipe has features which could affect the measure, i.e. rust, dirt… Measure the pipes’ diameter by using a callipers B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 18
Or, if it is not possible to measure the diameter, please measure the pipe’s circumference: III. Clean the area where the sensors will be installed by using one of the following tools: B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 20
The pipe section where the sensors will be installed should be completely clean: Measure the pipe’s thickness. This could be done by using our Thickness Gauge TT100-TM8812-NG B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 21
Now it is possible to start the sensors installation. Please remember to use the coupling grease: Otherwise, the sensor could loose grip to the pipe. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 22
Sensors could be installed by using a fixing bracket: Or by using our Rail Guide Mounting System RGMS-TS2-TM1-NG-FIX (only with TS2 & TM1 sensors, pipes form DN15 to DN300). B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 23
Install the sensors according to the distance value the device displays in MENU 25: a) Installation of the clamp-on sensors with the fixing brackets: Installation is completed: B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 24
Installation of the clamp-on sensors with our Rail Guide Mounting System RGMS-TS2-TM1-NG-FIX (only with TS2 & TM1 sensors, pipes form DN15 to DN300). Installation is completed: B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 25
The following example shows the different mounting solutions. “Z” m ounting m ethod “V” m ounting m ethod “N” m ounting m ethod B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 26
Z mounting method is suggested only if the signal strength, UP and DOWN (DN) is smaller than 60 and Q value is smaller than 60, see MENU “90”. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Use a small quantity of coupling grease in order to improve acoustic the contact between the sensor and the pipe’s external surface. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
25. Additionally, add a piece of paper to wrap the pipe. Please refer to the picture below for finding the two lines needed to trace the exact half point of the pipe. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 29
V - M e t h o d Z - M e t h o d = > 2 . N - M e t h o d B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 30
D e f a u l t S e t t i n g [ 2 6 > 1 . S o l i d i f y S e t t i n g B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
S t r e n t h + Q u a l i t y S = 0 0 0 , 0 0 0 Q = 0 0 D e t e c t N o S i g n a l B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
T O M / T O S * 1 0 0 x x x , x x % And eventually confirm the right mounting method. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
54 AI5 Value Range 60 Date and Time 61 Software Version and Serial Number (ESN) 62 RS-232C Setup 67 FO Frequency Range B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
S = 6 7 9 , 6 8 1 Q = 5 6 R This a display window. The measuring units should be set up in menu M31 and M36. The NEG value refers to the negative totalizer. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 37
B a t t e r y W o r k t i m e 0 0 : 4 5 : 3 4 This window displays the battery features and status. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 38
/ s S = 6 7 9 , 6 8 1 Q = 5 6 R This window displays the net daily flow rate. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
This window is used to set up the pipe’s material. Press ENTER to activate the material selection. Use the arrow keys to scroll among the list: B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 40
Use the arrow keys to scroll among the list: 0 NO Liner 1 Tar Epoxy 2 Rubber 3 Mortar 4 Polypropylene 5 Polystyrol B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it VAT No. IT02459940280...
Page 41
I n s i d e A B S T h i c k n e s s [ 1 8 This menu is not used, please ignore it. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 42
For inform ation about the sound speed through other types of m aterials that are not included in the list, please refer to the tables starting at page 70. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 43
Selection No. 3 “USER TYPE” allows the user to install types of sensors not included in the list. In this case, it is necessary to enter some more information about the technical features of the new type of sensors: B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 44
T r a n s d u c e r S p a c i n g 3 8 5 . 2 6 8 m m This window informs about the mounting distance of the transducers. See. Par. 2.4-2.5. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 45
This window is used to set up a min threshold. Below that threshold the device considers the pipe as empty. Set up a value among 30 and 40 in order to be sure the device does not measure when the pipe is empty. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Use the arrow keys to select the time units to which the current flow rate should refer: /hour /day /min /sec B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 48
Press ENT and then use the arrow keys to select NO or YES. If YES is chosen, please select among: None NET TOtalizer POS Totalizet NEG Totalizer B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it VAT No.
Page 49
0 . 0 3 m / s This window allows the user to set up the speed threshold. Below that level, the device will display 0 flow rate and the totalization is stopped. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 50
S c a l e F a c t o r This window is used to set up the scale factor value. This value will affect the measure in order to correct the displayed value. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 51
M 4 9 C o m m T e s t e r This window is used to display the communication test with a remote device by serial port. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 52
0 0 : 0 0 : 0 0 This window is used to set up the data logging time. It should be set to go on until a definite time set by the user. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 54
Even Press ENT to confirm the selection and exit the setting. The other parameters are factory set up: 8 bit data, 1 bit stop and flow control Xon/Xoff. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 55
This window is used to set up the display contrast. Press ENT and the use the arrow keys to select a value from 0 up to 31. Press ENT again to confirm the selection. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 56
5 0 0 3 / h This window is used to set up the max. flow rate threshold for alarm 1. press ENT, digit the flow rate value and press ENT again. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 57
Poor signal Not ready Reverse flow A.O. Over 100% F.O. Over 120% Alarm #1 Alarm #2 B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it VAT No. IT02459940280...
Page 58
2006 at 23:59:59. press the ↑ key to scroll the other 63 loggings. Press ENT to exit this display. Menus M83 and M84 are not used. They will be implemented in the next software versions. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 59
Select between the two options and press ENT to confirm. WARNING!!! THE FOLLOWING MENU 86, 87, 88, 89 ARE FOR EXPERT USERS ONLY. B.M. TECNOLOGIE INDUSTRIALI SUGGESTS NOT TO CHANGE THEM. PLS LEAVE THE FOLLOWING MENUS AS DEFAULT SET. Digit and the device will display...
Page 60
We suggest not to change this menu. Leave it as factory default. If needed, select between the options and press ENT to confirm. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 61
This window displays the total transit time and the UP-DOWN difference between transit times. The values give information about the installation. In normal working conditions the difference is less than 10%. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 62
M + 3 L a s t F l o w R a t e 0 m 3 / h Press the ↓ key to display: B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 63
S H P _ _ _ _ _ _ _ _ _ _ _ This window displays the signal received from the sensors: GOOD SIGNAL BAD SIGNAL B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 64
Page 64 of DIAGNOSTICS AND PROBLEM SOLVING The TTFM100B-HH-NG series has a complete series of diagnostics functions: it has a continuous searching for errors or bad working conditions. The continuous displaying of errors helps the customer identifying damages or unacceptable working conditions.
Page 65
Reset the device by using M41 function. Check that the flow is completely static. c. The battery works for a short period. Shorter than what stated in M07. Replace the battery: it is over. Contact B.M. Tecnologie Industriali. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54...
Page 66
GND- Back signals OCT Output- Positive Pole output (+) Not Used Battery charger Negative pole input (-) RING input for MODEM connection B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it...
Page 67
CONNECTOR USED TO LOAD UP TO 6 CONTROLS. (CR)= CHANGE OF LINE “d”= DIGIT BETWEEN 0…9 @= KEY VALUE. B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it VAT No.
Page 68
Flow rate, Speed and POs Totalizer. The control will be: W1234DQD&DV&DI+(CR), the reply will be +1.234567E+12m3/d(CR) +3.123456E+00m/s(CR) +1234567E+0m3(CR) B.M. Tecnologie Industriali Tel. +39 (0) 49 884.16.51 Via Praimbole 13 Fax +39 (0) 49 884.16.54 35010 LIMENA (PD) E-Mail bm@bmtecnologie.it VAT No.
Page 95
Vers.1.0 16/11/2005 Page 95 of Because of B.M. Tecnologie Industriali policy of improving their products, the TTFM100 series, would be revised and improved. Please inform us about misunderstandings or errors which You may find in this manual comparing it to the device You bought.
Need help?
Do you have a question about the TTFM100B-HH-NG and is the answer not in the manual?
Questions and answers