Telco 2111-12-01 Installation & User Manual

Metrobility twister 2111 10 mbps media converter

Advertisement

Quick Links

®
®
Metrobility
"twister"
2111
10 Mbps Media Converter
Installation & User Guide
Models: 2111-12-01 / 2111-13-B / 2111-15-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2111-12-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Telco 2111-12-01

  • Page 1 ® ® Metrobility “twister” 2111 10 Mbps Media Converter Installation & User Guide Models: 2111-12-01 / 2111-13-B / 2111-15-B...
  • Page 2 No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic, mechanical, chemical, optical or otherwise, without prior explicit written permission of Telco Systems, Inc. © 2006 Telco Systems, Inc.
  • Page 3: Table Of Contents

    Warranty and Servicing ................21 Metrobility Optical Systems, Metrobility, Lancast, NetBeacon and “twister” are registered trademarks; the Metrobility Optical Systems logo and WebBeacon are trademarks of Telco Systems, Inc., a BATM company. All others are trademarks of their respective owners. The information contained in this document is assumed to be correct and current. The manufacturer is not...
  • Page 4: Introduction

    Introduction Metrobility® “twister”® media converters represent the hottest technology available for extending Ethernet networks. Since its first development “twister” media conversion, it has become a standard for providing cost-effective means of integrating mixed media environments. As LANs grow and evolve, this technology provides the ideal solution for building effective migration strategies.
  • Page 5: Installation Guide

    Installation Guide Follow the simple steps outlined in this section of the guide to install and start using your Metrobility “twister” media converter. Unpack the “twister” and Accessories Check that the following components have been included with your order: • “twister” 2111 media converter •...
  • Page 6: Step 4: Set The Switches

    Set the Switches Termination Switch (2111-12-01 only) The “twister” 2111-12-01 has a termination switch located on the front panel. This switch, labeled TERM, is used to set either internal or external termination on the BNC port. External termination is enabled when the switch is in the OFF position (default).
  • Page 7: Transparency Switch

    Transparency Switch (2111-13-B and 2111-15-B only) The “twister” 2111-13-B and 2111-15-B have a set of DIP switches located on the back panel. Only the transparency switch, labeled TSP, is configu- rable. All other DIP switches are nonfunctional. When TSP is ON (default), the “twister” becomes completely transparent to the end devices connected to its two ports.
  • Page 8: Mdi-Ii To Mdi-X Switch

    MDI-II to MDI-X Switch All “twister” media converters with twisted-pair ports have an MDI-II to MDI-X switch that eliminates the need for crossover cables. The switch al- lows simple setup in either straight through or crossover configurations. It is located on the bottom of the unit directly below the RJ-45 connector, or on the front panel between the two ports.
  • Page 9: Step 5: Connect To The Network

    Connect to the Network The Metrobility “twister” 2111 media converter offers the ease of plug- and-play installation. Refer to the appropriate section below for guidelines regarding specific network connections. Twisted-pair Interface (all models) The “twister” 2111 provides one shielded RJ-45 connector for Category 3, 4, or 5 twisted-pair segments and supports a maximum link length of up to 100 meters.
  • Page 10: Fiber Optic Interface

    Fiber Optic Interface The following “twister” models support 10BASE-FL segments via ST or SC connectors. • The 2111-13-B provides one set of FL multimode SC connectors, which support a maximum segment length of up to 2 km for remote links. •...
  • Page 11 (2111-12-01) The “twister” 2111-12-01 attaches to thinnet coaxial cable via a standard BNC connector and supports a maximum segment length of 185 meters. IMPORTANT: The coaxial cable of a LAN must be properly terminated at the end of each segment regardless of the device used at the end of each cable.
  • Page 12: Step 6: Apply Power

    When the termination switch on the “twister” is disabled (OFF), you must attach a BNC terminator to the T-connector which connects to the unit. The example below illustrates how to connect the “twister” 2111-12-01 when the termination switch is disabled and when it is enabled.
  • Page 13 Power is provided to the “twister” unit from the 90-250V universal desktop power supply module. This power module is equipped with a S760 hollow- type plug for insertion into the DC jack located on the back of the “twister” unit and standard IEC 320-type AC power receptacle. When making power connections, it is recommended that the DC power cord be connected to the DC input jack located on the back of the “twister”...
  • Page 14 • AC 115V (North American): use a UL-listed and CSA-certified cord set consisting of a minimum No. 18 AWG, type SVT or SJT three-conductor cord (15 feet maximum length) and a parallel blade grounding-type attachment plug rated 15A, 125V. • AC 230V (USA): use a UL-listed cord set consisting of a minimum No.
  • Page 15: User Guide

    (collision): detection of a collision condition and subsequent JAM packets generated on both segments. Once power is applied to the unit, you can verify correct connectivity via the LK LED(s). Applies to the “twister” 2111-12-01 only. Metrobility 2111 Media Converter...
  • Page 16: Transparency Mode

    Transparency Mode (2111-13-B and 2111-15-B only) By default, the “twister” 2111-13-B and 2111-15-B are configured with the Transparency Mode enabled (ON). In this mode, the “twister” is completely transparent to devices connected to its ports. To the end devices, it appears that they have a direct connection to each other and can auto-negotiate their duplex mode.
  • Page 17 Switch/Hub Remote Management 2111-xx-B 2111-xx-B w/SNMP Device Station “twister” “twister” AN is OFF TSP is ON TSP is ON AN is OFF Link loss is forwarded LED lit = established link LED unlit = no link When the Transparency Mode is disabled (OFF), you must manually configure the speed and duplex on both end devices to the same setting.
  • Page 18: Topology Solutions

    Topology Solutions User Guide...
  • Page 19: Technical Specifications

    ___________________________ -19 dBm to -14 dBm (62.5/125 µm) Supported Link Length ______________________________ up to 2 km full duplex Cable Type _____________________________ 50/125, 62.5/125, 100/140 µm F/O Thinnet Coax Interface (2111-12-01) Connector _____________________________________________ BNC receptacle Internal Transceiver _________________________________________IEEE 802.3 Supported Link Length ______________________________________ up to 185 m...
  • Page 20: Product Safety, Emc And Compliance Statements

    Product Safety, EMC and Compliance Statements This equipment complies with the following requirements: • • • EN60950 (safety) • FCC Part 15, Class A • EN55022 Class A (emissions) • EN55024: 1998 (immunity) • IEC 825-1 Classification • Class 1 Laser Product •...
  • Page 21: Warranty And Servicing

    TELCO MAKES NO WARRANTIES EXCEPT AS HEREIN SET FORTH: Telco warrants that the equipment and accessories manufactured by Telco, when used in the application and manner for which they are intended, will be free from defects caused by faulty material or poor workmanship from the date of shipment.
  • Page 22 US Headquarters 2 Hampshire Street Suite 3A Foxboro MA USA 02035 tel: 1.781.551.0300 • fax: 1.781.255.2344 www.telco.com Int'l Headquarters Germany Asia Pacific France tel: +972.9.866.2525 tel: +49 (0) 5331.8824.0 tel: (65) 6722.529901 tel: +33 (0) 1,567.12.773 5660-211112-001 N 12/06...

This manual is also suitable for:

2111-15-b2111-13-b

Table of Contents