Advertisement

MSKOMMV
kÉï=~ë=çÑW==
áåcáêÉ=eq`
léÉê~íáåÖ=fåëíêìÅíáçåë
båÖäáëÜ

Advertisement

Table of Contents
loading

Summary of Contents for Sirona inFire HTC

  • Page 1 MSKOMMV kÉï=~ë=çÑW== áåcáêÉ=eq` léÉê~íáåÖ=fåëíêìÅíáçåë båÖäáëÜ...
  • Page 2: Table Of Contents

    Sirona Dental Systems GmbH Contents Operating Instructions inFire HTC Contents Dear customer, ..................... General information ..................Structure of the documents .............. Warranty ................... Safety information..................Technical description..................Description of the furnace ..............Certification ..................Intended use ..................Technical data ..................
  • Page 3 Sirona Dental Systems GmbH Operating Instructions inFire HTC Contents Display and acoustic signal .............. Adjustment of the start time (casting time function) ......Regular care ....................Malfunctions ....................Error messages from electronic components ........Miscellaneous errors and their causes ..........
  • Page 4: Dear Customer

    Sirona Dental Systems GmbH Operating Instructions inFire HTC Dear customer, Thank you for purchasing your inFire HTC from Sirona. It will support you with your work for many years, as it was developed and built with state-of-the-art technology. Nevertheless, improper use and handling can cause damage and hazards.
  • Page 5: General Information

    Sirona Dental Systems GmbH 2 General information Operating Instructions inFire HTC Structure of the documents General information CAUTION Be sure to observe all warnings! Please observe the warning and safety information provided to prevent personal injury and material damage. Any such information is highlighted by a signal word, i.e.
  • Page 6: Warranty

    2 General information Sirona Dental Systems GmbH Warranty Operating Instructions inFire HTC Warranty To safeguard your warranty claims, please complete the attached Installation Report / Warranty Passport when the system is handed over. Then fax it to the specified fax no.
  • Page 7: Safety Information

    For reasons of product safety, this product may be operated only with original Sirona accessories or third-party accessories expressly approved by Sirona. The user assumes the risk of using non-approved accessories. If any equipment not approved by Sirona is connected, it must comply with the applicable standards: ●...
  • Page 8 Operating Instructions inFire HTC CAUTION Damage resulting from unauthorized alterations The inFire HTC high-temperature furnace may only be altered with our express prior approval. We are not liable for unauthorized alterations of any kind. ➢ Switch the unit off and disconnect the power plug prior to performing maintenance tasks.
  • Page 9: Technical Description

    Council Directive 73/23/EEC of February 19, 1973 concerning electrical equipment designed for use within certain voltage limits. We declare conformity for the inFire HTC ceramic sintering furnace on the basis of the following standards: ● Safety: IEC 61010-1:2001 2nd edition and IEC 61010-2-010:2003 2nd edition ●...
  • Page 10: Technical Data

    4 Technical description Sirona Dental Systems GmbH Technical data Operating Instructions inFire HTC Technical data Rated line voltage: 200VAC - 240VAC Rated power frequency: 50/60Hz Rated current consumption: Type of protection against electric shock: Protection Class I device Degree of protection against ingress of water:...
  • Page 11: Setup

    Sirona Dental Systems GmbH 5 Setup Operating Instructions inFire HTC Installation site Setup Installation site The unit is designed for desktop use and requires a level footprint of approx. 500 x 600 mm with a loading capacity of 80 kg.
  • Page 12 5 Setup Sirona Dental Systems GmbH Electrical connection Operating Instructions inFire HTC Building installation The following requirements must be met for electrical installation of the inFire HTC ceramic sintering furnace: ● The furnace requires a separate electric circuit. ● The electrical building installation must be protected by a slow-blow fuse with a rating of at least 15A.
  • Page 13: Operation

    Sirona Dental Systems GmbH 6 Operation Operating Instructions inFire HTC Controls and displays Operation Controls and displays The controller is equipped with state-of-the-art microprocessor technology, which allows for processing a great variety of heating curves with utmost precision. The operation of the unit is menu-driven via a membrane keyboard and an LCD display.
  • Page 14: Key Functions

    6 Operation Sirona Dental Systems GmbH Controls and displays Operating Instructions inFire HTC 6.1.1 Key functions Symbol Designation Function Start/Stop key starts/stops the selected program START STOP Load program key loads the program from memory Memory key saves a program to memory Casting time key For setting the casting time;...
  • Page 15: Switching On The Unit

    Sirona Dental Systems GmbH 6 Operation Operating Instructions inFire HTC Switching on the unit Right side Line Description READY Status of furnace (e.g. ) incl. number of furnace program entered (e.g. Current temperature of furnace chamber. Current Day of week and time.
  • Page 16: Practical Use

    6 Operation Sirona Dental Systems GmbH Practical use Operating Instructions inFire HTC Practical use Explanation The furnace can be used immediately after entering the required program. It is not necessary to preheat the furnace. CAUTION Risk of breaking The sintering trays to be used are fragile. They break with strong temperature fluctuations and under mechanical stress.
  • Page 17: Starting The Program

    Use the crucible fork to lift the sintering tray off of the rack. Place the sintering tray on the crucible rack with the crucible fork. Programs Explanation With the inFire HTC sintering furnace, sintering is controlled via callable programs [ 18]. ● inFire has fixed programs for sintering certain dental oxide ceramics.
  • Page 18: Select Program Number/Load Program

    6 Operation Sirona Dental Systems GmbH Programs Operating Instructions inFire HTC Program Designation IVOCLAR VIVADENT IPS e.max ZirCAD 6.4.2 Select program number/load program Select program number Press the Load Program key. LOAD PROGRAM screen is displayed. The cursor is on the program number.
  • Page 19: Freely Programmable Programs

    Sirona Dental Systems GmbH 6 Operation Operating Instructions inFire HTC Programs 6.4.5 Freely programmable programs Explanation This section explains the freely programmable settings (11-30). 6.4.5.1 Entering program values Programming step S1 Press the S1 key (S1 key for step S1).
  • Page 20 6 Operation Sirona Dental Systems GmbH Programs Operating Instructions inFire HTC °C 1540 Graphical representation This example describes the programming of program number 11 with the values of the table shown above. Press the Load Program key. Enter the program number Press the S2 key (= ) to confirm the loading procedure.
  • Page 21 Sirona Dental Systems GmbH 6 Operation Operating Instructions inFire HTC Programs Storing the program Press the Memory key. Press the S2 key (= The program is now stored under the number 6.4.5.2 Storing program values Explanation This section describes the procedure for storing changed program values of freely programmable settings (11-30).
  • Page 22: Default Settings

    7 Default settings Sirona Dental Systems GmbH Display and acoustic signal Operating Instructions inFire HTC Default settings Display and acoustic signal Explanation The display and the acoustic signal can be configured via two dialog boxes. Activation Press function key "F".
  • Page 23: Adjustment Of The Start Time (Casting Time Function)

    Sirona Dental Systems GmbH 7 Default settings Operating Instructions inFire HTC Adjustment of the start time (casting time function) Adjustment of the start time (casting time function) Explanation For calculation of the start time (when using the casting time function), the furnace controller assumes an average voltage of 230 V.
  • Page 24: Regular Care

    8 Regular care Sirona Dental Systems GmbH Operating Instructions inFire HTC Regular care The high-temperature furnace does not require any special care. The casing may be cleaned with a mild detergent. CAUTION Damage to the heating unit Avoid all contamination in the heating room to prevent damage to the heating unit.
  • Page 25: Malfunctions

    Sirona Dental Systems GmbH 9 Malfunctions Operating Instructions inFire HTC Error messages from electronic components Malfunctions Error messages from electronic components Error messages are displayed on the LCD screen. They are accompanied by an acoustic signal. Error message Cause Elimination SENSOR DEFECT Thermocouple not functioning properly.
  • Page 26: Miscellaneous Errors And Their Causes

    9 Malfunctions Sirona Dental Systems GmbH Miscellaneous errors and their causes Operating Instructions inFire HTC Miscellaneous errors and their causes Error Cause Elimination Wrong time displayed Wrong time in the controller Correct time settings (see function key "F" [ 22])
  • Page 27: Maintenance

    Sirona Dental Systems GmbH 10 Maintenance Operating Instructions inFire HTC Changing fuses F1/F2 Maintenance 10.1 Changing fuses F1/F2 Replacement fuse The order number for the replacement fuse is 61 30 681. Required tools 1x (flat) screwdriver Position Fuses F1 and F2 are located at the bottom left on the rear side.
  • Page 28: Disposal

    11 Disposal Sirona Dental Systems GmbH Operating Instructions inFire HTC Disposal Your product is marked with the adjacent symbol. Within the European Environmentally sound disposal Economic Area, this product is subject to Directive 2002/96/EC as well as the corresponding national laws. This directive requires environmentally sound recycling/disposal of the product.
  • Page 29: Index

    Sirona Dental Systems GmbH Operating Instructions inFire HTC Index Index Numerics controller ................. 13 Numeric keys ............14 day of week..............15 temperature steps............15 time ................. 15 Operation ................ 13 Acoustic signal..............22 Replacement fuse............27 Risk of breaking .............. 16 Risk of overheating ............
  • Page 30 tÉ=êÉëÉêîÉ=íÜÉ=êáÖÜí=íç=ã~âÉ=~åó=~äíÉê~íáçåë=ïÜáÅÜ=ã~ó=ÄÉ=êÉèìáêÉÇ=ÇìÉ=íç=íÉÅÜåáÅ~ä=áãéêçîÉãÉåíëK «=páêçå~=aÉåí~ä=póëíÉãë=dãÄe=OMMV péê~ÅÜÉW==ÉåÖäáëÅÜ= mêáåíÉÇ=áå=dÉêã~åó a=PQVTKOMNKMNKMQKMO MSKOMMV ûKJkêKW= NNN=ROV páêçå~=aÉåí~ä=póëíÉãë=dãÄe áå=íÜÉ=rp^W SN=PM=QRV=a=PQVT c~Äêáâëíê~≈É=PN páêçå~=aÉåí~ä=póëíÉãë=ii` lêÇÉê=kç SQSOR=_ÉåëÜÉáã QUPR=páêçå~=aêáîÉI=pìáíÉ=NMM dÉêã~åó `Ü~êäçííÉI=k`=OUOTP ïïïKëáêçå~KÅçã...

Table of Contents