Washdown Weighing Scale Service manual
(WB10D.PCB, FAT60K1-40B.HEX)
Model: KWD 1000 Series

FEATURES:

• Washdown scale to meet IP65 requirements
• 6 Key keypad
• 1" black LCD display with backlight
• 1/3000 External resolution
• Auto zeroing and tare function
• Kg/lb unit weight conversion
• Overload protected load cell
• Low power indication
• Rechargeable battery (DC 6V / 4.5A) or 120VAC 60 hz. power.
Before using for the first time:
Place the scale on a stable surface.
Adjust four feet to center the leveling bubble on the scale.
Avoid hot direct sunlight. Do not place scale near ventilation system.
Power supply
:
Power switch: it is located on the underside of the indicator.
Scale can be plugged directly into wall outlet for use or for charging.
Power consumption: about DC 20mA, with backlight about DC 40mA.
Indicator will blank-out and low battery icon flashes to indicate the battery needs recharging. In order to
prolong battery life, recharge the battery every day.
Note:
When recharging, do not share power with other equipment and avoid electromagnetic interference from other
devices.
If the scale will not be used for long period of time, the scale must be recharged (internal battery) every 3 months.
Recharge scale before using.
Red, which means charging and green means charging is finished.
Page 1 of 8
# 2004(WB10D)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KWD 1000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Kilotech KWD 1000 Series

  • Page 1 KILOTECH Washdown Weighing Scale Service manual # 2004(WB10D) (WB10D.PCB, FAT60K1-40B.HEX) Model: KWD 1000 Series FEATURES: • Washdown scale to meet IP65 requirements • 6 Key keypad • 1” black LCD display with backlight • 1/3000 External resolution • Auto zeroing and tare function •...
  • Page 2 Available capacity and division: The KWD 1000 is available in 3 capacities. Ask your dealer for more specifications Resolution Capacity Division 1/3000 60 kg 20 g 1/3000 150 kg 50 g 1/3000 300 kg 100 g Keypad Function: 1. ZERO (+) : a)Press this key to return the display to “0” reading. b)Press this key to deduct the empty container weight.
  • Page 3 1. Ensure that there is no weight on the scale platform. 2. Place an empty container on the scale platform 3. Press the TARE key to deduct the weight of the empty container. 4. Place a weight in the container to obtain the net weight of the item. •...
  • Page 4 Use maximum (full) capacity weighing standard to calibrate to avoid any difference. Minimum is 1/6. Do not use weighing standards beyond maximum capacity of scale. Keep the scale stable during calibration. Installations & Attentions Use correct power supplied, connect ground line and do not share the power with other heavy duty equipment.
  • Page 5 Decimal or Hexadecimal numeration Hexadecimal PA 0 Unit weight when turn on power 0:kg . 1: lb (validity: L5=0) PP 0 Display times at per second. Range:00-99 times to display per second.(adapt A4) PL 10 PH 0 Stability Range:00-99 to select difference of stability(adapt A4) Kg/lb or g/oz unit weight conversion 0: kg/lb conversion P0 0...
  • Page 6 6. When displays P0 0 press ZERO to select ‘kg/lb’, ‘kg/kg’ as unit, then press HI/LO (0: kg/lb, 1: kg/kg) 7. When displays P1 0 press ZERO key to choose nearby zero ±? division to display ‘0’ then press HI/LO ( 0: no function, 01..99 ±? division ) 8.
  • Page 7 How to set up capacity, graduation & weighing standard calibration After each set up, you may turn off and on the scale to operate (do not need to go through to the end) . 1. Find the unlock code J8 jumber on mainboard to let it ‘ON’, then press NW/GW→and turn on power at same time.
  • Page 8 calibration process. ---OL--- Means over loading (OL at 9 divisions over max. capacity) or load cell is disconnect. Display Value drifts….. Increase the value of PL and PH settings. This will increase stability but decrease display speed. No BEEP after calibration The load cell signal (S+, S-) is incorrectly installed. Check and re-install. Indicator lights blink If this happens during calibration, the load cell connections may be installed incorrectly.

Table of Contents