UEIUA CMTP03-2405 Instruction Manual

UEIUA CMTP03-2405 Instruction Manual

Cmtp03 series solar charge controller

Advertisement

VODASI
CMTP03 series solar charge controller
Note: if you have any queries or changes, you can contact with Vodasi company or our dealers.
Model:CMTP03-2405, CMTP03-2410, CMTP03-2415, CMTP03-2420
CMTP03-4805, CMTP03-4810, CMTP03-4815, CMTP03-4820
Description of product model:
CMTP03-24 05
05 represents the maximum discharge current 5A
24 represents the maximum voltage, means 12V/24V auto-identity, means12V/24V/48V auto-identity
* In the initial stage controller electrify, the controller can automatically identify the rated voltage of the system
battery terminal voltage ≤16V
18V<battery terminal voltage≤32V
36V<battery terminal voltage≤64V
Note:
1. The intermediate 16V-18V, 32V-36V are the system blind zone, the controller has no response;
2. The safety voltage of battery must less than 64V;
3. While testing the controller if you use the switch power supply or other adjustable power supply input, and the test voltage
exceeds 40V, please well connect the power line of the battery first and then adjust the voltage to the target test voltage.
Otherwise the controller may break down cause the voltage of the power supply has an overshot that exceed than 64V. It is
feasible
to do the power ON / OFF test if you use the battery power supply, and the voltage is within 48V.
Please do not use the adjustable power supply to do more than 40 V input power ON / OFF test!
Chooses us, chooses the specialty!
INSTRUCTION
MANUAL
12V system
24V system
48V system
Website:
http://www.vodasi.com
VODASI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMTP03-2405 and is the answer not in the manual?

Questions and answers

Summary of Contents for UEIUA CMTP03-2405

  • Page 1 CMTP03 series solar charge controller INSTRUCTION MANUAL Note: if you have any queries or changes, you can contact with Vodasi company or our dealers. Model:CMTP03-2405, CMTP03-2410, CMTP03-2415, CMTP03-2420 CMTP03-4805, CMTP03-4810, CMTP03-4815, CMTP03-4820 Description of product model: CMTP03-24 05 05 represents the maximum discharge current 5A...
  • Page 2: Product Overview

    VODASI Website: http://www.vodasi.com Product overview 1. Use single-chip microcomputer as the core of the whole control system, which makes the controller has the advantages of intelligent, strong adaptability, reliable function etc. 2. Use Vodasi 03 version optimized design scheme, which can improve system efficiency and prolong the life span the battery. 3.
  • Page 3 VODASI Website: http://www.vodasi.com Step 3: Mark Holes Use a pencil or pen to mark the four (4) mounting hole locations on the mounting surface. Step 4: Drill Holes Remove the controller and drill 4mm holes in the marked locations. Step 5: Secure Controller Place the controller on the surface and align the mounting holes with the drilled holes in step 4.
  • Page 4: Troubleshooting

    VODASI Website: http://www.vodasi.com 2、Status instructions Here we take the 12V voltage system as an example, 24V ×2,48V×4,Voltage parameters error ± 3% ① PV charging status indicator Constant ON(the voltage of solar panel should higher than 10V ) Flashing(in the state of float charge) ②...
  • Page 5: Technical Data

    Check the wiring whether is tight or not, and the automatic identification of 12V/24V/48V system is correct or not. Note: We keep right to change and update without prior notice. Technical Data Model CMTP03 12V/24V AUTO CMTP03-2405 CMTP03-2410 CMTP03-2415 CMTP03-2420 12V/24V/48V AUTO CMTP03-4805 CMTP03-4810...