scandia 240 Installation Instructions & User Manual

scandia 240 Installation Instructions & User Manual

Ultra-sauna heater
Hide thumbs Also See for 240:

Advertisement

I n s t a l l a t i o n
ULTRA-SAUNA HEATER
Proudly made in USA since 1964
Gas Heaters - 40,000-80,000 BTU
Installation Instructions
PO Box 636 Eagle Idaho USA. 83616
T: 877.467.2862 F: 208.286.0290 info@scandiamfg.com www.scandiamfg.com
G u i d e
& User Manual
Heater Model __________
Serial #
__________
1

Advertisement

Table of Contents
loading

Summary of Contents for scandia 240

  • Page 1 Heater Model __________ Serial # __________ I n s t a l l a t i o n G u i d e ULTRA-SAUNA HEATER Proudly made in USA since 1964 Gas Heaters - 40,000-80,000 BTU Installation Instructions & User Manual PO Box 636 Eagle Idaho USA.
  • Page 2 Sauna room should never have tile walls or benches  Do not treat or varnish sauna wood  Use only Scandia high density sauna rocks  Check and clean rocks and rock tray twice a year or as needed ...
  • Page 3 Scandia Ultra Sauna Gas Heater Component List Heater Component List Heater Body Unit Back panel w/external through-wall covers Stainless steel flashing (internal back panel cover) Venting component option (flue cap or draft hood) Complete burner assembly (natural gas or propane)
  • Page 4 60 sq ft (5.57 sq m) 88 sq ft (8.15 sq m) 80,000 BTU 80 sq ft (7.43 sq m) 240 sq ft (22.30 sq m) 80,000 BTU 80 sq ft (7.43 sq m) 240 sq ft (22.30 sq m)
  • Page 5 Rough-in Sizing guidelines Note: Your Scandia Ultra gas sauna heater should be installed only by a licensed electrician and HVAC professional. Improper or unofficial installation will void warranty. Gas Line 40,000 BTU 80,000 BTU 0.515625" x 0.515625" 18.5" 29" 8"...
  • Page 6 Rough-in control box and interior back panel 40,000 BTU Heater (240/245) Installing the back panel  Back panel should be installed when sauna room is framed in prior to the finishing steps of the sauna room  Back panel is mounted directly to the face of the studs ...
  • Page 7 Exterior Back Panel Rough-in 20 1/4” 40,000 BTU Heater (240/245) Back Panel 6 1/4” Through-wall rough-in. 32 1/4” ” A) Exhaust vent (W 9 1/2 in x H 9 1/2 in) ” Intake vent (W 13 3/4 in x H 6 in) Exhaust Vent ”...
  • Page 8 11. attach the thermostat probe ten inches below ceiling as far away from heater as possible. The probe must be placed horizontally in the provided thermostat probe cover. 12. Install heater guard rail. Chassis 240/245 280/285 Width Of Heater Shell 18 1/2” 29”...
  • Page 9 Scandia Ultra-Sauna Heater Guard Rail SAUNA heater Upper bench Lower bench 0.20564516129032" x 0.20564516129032" 0.41129032258065" x 0.41129032258065" TOP VIEW Back Wall HEATER Heater vent Rails are spaced 3-3/4 ” apart Back wall SIDEVIEW FRONT VIEW Components for 3-sided heater guard:...
  • Page 10 Scandia/Vico Gas Burner Overview and installation instructions Gas Burner Overview - Standing Pilot Pilot Generator Assembly Includes: Thermopile and pilot light Gas Burner Thermopile wires to gas valve at base of burner assembly Gas Valve Pilot Light pre-plumbed to gas valve...
  • Page 11 60 Minute Control Wiring Overview Pilot Generator Wire: Pilot Gas Line: Two wires from gas valve to pilot Gas line that feeds to Thermostat to Gas Valve assembly (one red, one white) pilot light assembly Use red wire from control lead wire. White wire to pilot gen text...

This manual is also suitable for:

245285280

Table of Contents