This manual describe the wiring and setting to operate the multi-protocol Oxtopus router EIA-709
and Modbus
01/06/2015

Advertisement

Table of Contents
loading

Summary of Contents for OCCITALINA OXTOPUS EIA-709

  • Page 1 User Manual Installation – Router setting This manual describe the wiring and setting to operate the multi-protocol Oxtopus router EIA-709 and Modbus 01/06/2015...
  • Page 2 User Manual This manual is organized in different chapter. Each can be read independently. The annexes are supplements to use routers in their environment. OCCITALINE Centre Commercial Plein Centre Allée du Quercy 31770 Colomiers France +33(0)5 34 28 12 24 support@occitaline.com Release EN 0.93 Page 1/53...
  • Page 3 User Manual Terminology Name usually given to the protocol or component working in EIA-709.1. ® LonWorks Name given to the communication system developed by Echelon Corp under denomination EIA-709.1 or ISO-14908.1. Modbus Protocol used in building automation and industry for exchange data between two devices.
  • Page 4: Table Of Contents

    User Manual Contents INTRODUCTION ANGE OF XTOPUS ROUTERS THERNET CONNECTION – E ONNECTION THERNET UTOMATION PROTOCOLS SUPPORTED 1.5.1 EIA-709.1 OUTER 1.5.2 NAT M OUTER ODBUS THER PROTOCOLS SUPPORTED 1.6.1 EIA-852 D EVICE 1.6.2 EIA-852 C ONFIG ERVER 1.6.3 1.6.4 ISK SPACE EMBEDDED IN CONNECTING AND MATERIAL THERNET OWER...
  • Page 5 User Manual 4.2.1 EVICE INFO 4.2.2 THERNET CHAPTER 4.2.3 ORTS CHAPTER ENUS OGIN PAGE SER MODIFICATION ACCOUNT EBOOT PAGE YSTEM CONFIGURATION ONFIGURATION EIA-709 4.10 EIA-852 C LIENT 4.11 HE CONFIG SERVER 4.12 HANNEL LIST 4.13 EIA-709 ONFIGURATION OF ODBUS SERVER 4.14 ONFIGURATION ODBUS SERIAL...
  • Page 6: Introduction

    User Manual 1 Introduction Release EN 0.93 Page 5/53...
  • Page 7: Range Of Oxtopus Routers

    User Manual 1.2 Range of Oxtopus routers Oxtopus routers are available in several product references. Port TP/FT10 Port EIA-485 Reference Ethernet Port Wifi EIA-709 Modbus Ox-1Lo 2 in Switch Ox-1Lo-Wi 2 in Switch Ox-2Lo 2 in Switch Ox-2Lo-Wi 2 in Switch Ox-3Lo 2 in Switch Ox-3Lo-Wi...
  • Page 8: Ethernet Connection

    User Manual 1.3 Ethernet connection All references are equipped with two RJ45 connectors. Communication can be done independently on both sides with network. Figure 2 Ethernet Connectors Eth0 and Eth1 The two RJ45 Ethernet connectors are configured in factory as Ethernet switch. The main connector is the left ETH0.
  • Page 9: Automation Protocols Supported

    User Manual 1.5 Automation protocols supported The EIA-709.1 and Modbus protocols are supported on Oxtopus router and run on IP separately. 1.5.1 Router EIA-709.1 In Oxtopus routers, the EIA-709.1 protocol is available either on twisted pair or over IP. In order to pass from one media to another, it is implemented in a router function.
  • Page 10: Other Protocols Supported

    User Manual Configuration example: Slave source Port EIA-485 Slave destination address address Port 3 Port 3 Port 4 Port 4 1.6 Other protocols supported 1.6.1 EIA-852 Device This protocol is transparent for the installer and operator of the router. It is used for exchanges between members of a Channel IP.
  • Page 11: Connecting And Material

    User Manual 2 Connecting and Material Release EN 0.93 Page 10/53...
  • Page 12: Ethernet

    User Manual 2.1 Ethernet The cables used should not exceed 90 meters. The left connector Eth0 must be privileged. The default address is 192.168.1.254. 2.2 Wifi The connection can support multiple devices. It can be enabled or disabled on the router with buttons and the LCD display or on the Web page 2.3 Power The material feed may be made in DC voltage or AC voltage.
  • Page 13: Wired Network Eia-709.1 / Eia-485 Modbus

    User Manual According to reference product 1, 2, 3 or 4 EIA-485 ports, the ports are used starting from left or following EIA-709. Reference Port 1 Port 2 Port 3 Port 4 TP/FT10 EIA-485 Ox-1Lo-1Mo EIA-709.1 Modbus TP/FT10 EIA-485 EIA-485 Ox-1Lo-2Mo EIA-709.1 Modbus...
  • Page 14: Led Signalization

    User Manual 2.6 LED signalization 2.6.1 Power LED The POWER LED is ON in Green at the beginning of power on. A red color indicates a fault on the router. 2.6.2 Wifi LED For Oxtopus routers with wifi option, WIFI LED will be green to indicate that wifi is active; the red color indicates that the wifi is inactive.
  • Page 15: Led Z

    User Manual 2.6.4.1 LON FT/TP-10 EIA 709 Port of Oxtopus router has a bicolor LED: Behavior Description Comment GREEN blinking Traffic Receiving or sending frame GREEN blinking at 1HZ Port Not configured RED blinking Errors on medium Lost frame due to: CRC Error Most important Traffic 2.6.4.2 Modbus RS485...
  • Page 16 User Manual Press one of the buttons to access the menu which indicates the router configuration and bandwidth usage in real time to the ports LON FT / TP10. Figure 10 : First page menu Buttons below the arrows are used to select the port. Once selected, press the button under the symbol "SP"...
  • Page 17: Easy And Fast Setting

    User Manual 3 Easy and fast setting Release EN 0.93 Page 16/53...
  • Page 18: Wizard For Configuration

    User Manual 3.1 Wizard for configuration A wizard has been developed to simplify the configuration of Oxtopus router. Questions are asked in specific order. At the end of the sequence, the reboot of the router places it in the desired configuration. The steps are: 1.
  • Page 19: Login Page

    User Manual 3.3 Login page When access to a configuration page, if the user is not logged, the login page is proposed. (See Chapter 3.3) The account is "admin", password is "oxpass". 3.4 Name of router The name will be visible on the LCD screen and in the members list of the Channel IP. Figure 13 Define router name 3.5 IP address...
  • Page 20: Wifi Configuration

    User Manual 3.6 Wifi configuration This page allows you to enable or disable the Wifi as well and set the access parameters. Figure 16 Disabling Wifi option If WiFi is activated from the LCD screen, the values stored in the configuration will be used. By enabling WiFi by the Web, you can change its setting.
  • Page 21: Eia-852 Configuration

    User Manual 3.7 EIA-852 configuration The router side IP must be a member of an IP Channel. The router can handle this task with its "Server Config". Default routers come with the "config server" disabled. Figure 18 EIA-852 setting without Config Server In case of the "config server"...
  • Page 22 User Manual Figure 20 EIA-852 setting with Config Server WITOUT adding router to the Channel IP If you do not want to add the router to the members of Channel IP managed by this router, you must enter the address of its "Server Config". Figure 21 Member list of the Channel IP On the first time on this page, if you have checked the checkbox "Adding the router to the...
  • Page 23: Modbus Configuration

    User Manual 3.8 Modbus configuration This page defines the communication port used by the Modbus IP Server (default 502). The protocol is TCP / IP. A field also sets a rerouted slave address to get Modbus ports and EIA-709.1 statistics of routers’s Neuron Chip.
  • Page 24: Confirm And Reboot

    User Manual Figure 24 Translation address table for Modbus 3.9 Confirm and reboot This page will record into the router all parameters entered by the user. Figure 25 Validation du Wizard The values will be used after the reboot or by turning off / on the router. Figure 26 Router reboot After validation, wait for 15 to 20 seconds for restart.
  • Page 25: Details Settings

    User Manual 4 Details settings Release EN 0.93 Page 24/53...
  • Page 26: Resizable Page To The Screen Device

    User Manual 4.1 Resizable page to the screen device The Web site is automatically adapted to the device that consults. Figure 27 Home page on computer When the device menu width no longer fits to the left, it is reduced and can be opened by the top right button.
  • Page 27: Home Page

    User Manual 4.2 Home page The home page displays the router's condition: configuration, impedance mismatches, sending services pin of each EIA-709.1 ports. This page is not protected by password. Figure 29 Complete home page Several panels are displayed according to the reference product. Release EN 0.93 Page 26/53...
  • Page 28: Device Info

    User Manual 4.2.1 Device info Figure 30 General Information Reference of the product is shown in banner title. This is the name of the router that is found among others on the LCD. Date/Time This is the current time of the router. It is used for log errors and statistics. Architecture It is the use of the two RJ45 connectors for Eth0 Eth1.
  • Page 29 User Manual Figure 32 General services on IP 4.2.2.1 General panel IP address of router. 4.2.2.2 Config Server panel Channel name This is the name of channel IP for rule « Config Server ». This name is only used by the user. He has no rule in the protocol. Nb member Number of members declared in channel list.
  • Page 30: Ports Chapter

    User Manual 4.2.3 Ports chapter In accordance with the reference product, the ports used are from 1 to 4. Each of them can be supplied for use in EIA-709 or Modbus. Figure 33 General on ports 4.2.3.1 EIA-709 port NID external External Neuron Id of router.
  • Page 31: Menus

    User Manual 4.3 Menus Menus are displayed on the left with a sufficient width terminal. If the width does not allow it, they fold out with the top right button. We find: Device info Home page Configuration Organized in system, Ethernet, Wifi, EIA-709.1 and Modbus Stats Graphical statistics Logs of communication and error...
  • Page 32: User Modification Account

    User Manual 4.5 User modification account Figure 36 User modification page With this page, the user can change his password and his language used after connection. The language for « guest user» modifies the default language for not logged users. 4.6 Reboot page This page will log into the router all the parameters entered by the user.
  • Page 33: System Configuration

    User Manual 4.7 System configuration This page allows you to change the router's name, date and time. Figure 39 Configuration system 4.8 Configuration This page allows to select the router's addressing mode. Either the IP address is dynamically assigned on the network by a DHCP server or it is manually assigned and called "static IP" address.
  • Page 34: Port Eia-709

    User Manual Figure 41 Configuration ETH0 with fixed IP 4.9 Port EIA-709 This page serves only to display the configuration of the EIA-709 router ports. Figure 42 Configuration des ports EIA-709 4.10 Port EIA-852 Client This page allows you to change the communication port for data exchange in EIA-852 Client (1628 by default) and the IP address and port (1629 by default) for the config server.
  • Page 35: The Config Server

    User Manual Figure 43 EIA-852 client configuration Its config server is not necessarily the router itself. That may be another router or a computer. It will specify the IP address and port used for this function. An EIA-852 port that has no config server cannot know the member with which he must share data.
  • Page 36: Channel List

    User Manual The IP address of the config server is IP address of the router itself. The port can be changed. The default value is 1629. Figure 45 Config server activated 4.12 Channel list This page allows adding, removing, enabling, exporting, importing and test members of IP channel.
  • Page 37: Configuration Modbus Serial Ports

    User Manual Figure 47 Configuration of slave address for statistics. Each Neuron Chip has a base address and each counter is set to a 16-bit word. The reading is done by a read command on an "Input Register" Modbus. 4.14 Configuration Modbus serial Ports This page allows to change all the serial parameters for Modbus serial ports Figure 48 ModBus serial port configuration...
  • Page 38 User Manual Figure 49 Router NAT Modbus configuration To each source slave address matches a serial port and a destination slave address on that port. This table allows to use the same destination slave addresses on all serial ports. Release EN 0.93 Page 37/53...
  • Page 39: Configuration Via Usb

    User Manual 5 Configuration via USB Release EN 0.93 Page 38/53...
  • Page 40: General Information

    User Manual 5.1 General Information For the USB driver installation and terminal, refer to the annexes 7.2 and 7.3. When your device is running and configured, press the "Enter" key to display the menu. There are two choices: - Restore the default IP address 192.168.1.254 - To restart Figure 50 Screen on terminal connected to the router...
  • Page 41: Restarting

    User Manual Figure 51 Confirmation load manufacturer values by “Y” The interface asks you to confirm by pressing "Y" or "N" to return to main menu The changing IP address will be effective after restart. Please note that restart is not done automatically after the IP address change 5.3 Restarting To reboot, select the "2"...
  • Page 42 User Manual Figure 52 Confirm Reboot by “Y” The interface asks you to confirm by pressing "Y" or "N" to return to main menu Release EN 0.93 Page 41/53...
  • Page 43: Smart Channel Usage

    User Manual 6 Smart Channel usage Release EN 0.93 Page 42/53...
  • Page 44: Preamble

    User Manual 6.1 Preamble To simply use the Oxtopus routers in NL220 or NLFacilities you must have placed specific files in the directory NLSmartChannel. See Appendix 7.1 These routers are equipped with an Ethernet port with an Ethernet switch on two RJ45 connectors and 1, 2, 3 or 4 ports TP / FT10.
  • Page 45 User Manual The name and type can be changed to fit to your project. Figure 54 Name and type of channel Once entered, you need to update by clicking the "Update" button. Figure 55 Channel modified following your needs NLSmartChannel assists you in adding your project infrastructure products. Media types are checked.
  • Page 46 User Manual Figure 57 Oxtopus routers You only have to choose the router version you want to install. After validation, you can resume operations to add another router of the same type or a different one. Figure 58 Plusieurs routeurs de type différents peuvent être ajoutés. With “CTRL-”"...
  • Page 47 User Manual Figure 59 Entering the NEURON Id If the router is turned on and connected to the Ethernet network, you can get its IP address by navigation with the buttons under LCD screen of router. Figure 60 IP address of Oxtopus router. This address is used in your Web browser to view the embedded Web server in the router Oxtopus.
  • Page 48 User Manual Each port sends its Neuron Id outside of the router. You will therefore be able to install the IP router in first. Then, for the other ports, you can activate the buttons on the home page or choose the port on the LCD screen and press the "[SP]." When you have entered all the Neuron Id and closed the window, you will find that the router is green in the tree.
  • Page 49: Appendix

    User Manual 7 Appendix Release EN 0.93 Page 48/53...
  • Page 50: Resources Installation For Nlsmartchannel

    User Manual 7.1 Resources installation for NLSmartChannel The compressed file "NL220_Resources.rar" allows software tools NL220 and NLFacilities to easily install the range of Oxtopus routers. Figure 63 Contain compressed file for NLSmartChannel Each directory in the compressed file contains files for defining Oxtopus routers. Figure 64 Directory where the files must be installed When the files are installed you will find the following directories:...
  • Page 51: Usb Driver Installation

    User Manual Figure 66 Directory Image Figure 67 Directory Document 7.2 USB driver installation 7.2.1 On Windows 8 Under Windows 8 when you plug the USB cable, the device is recognized automatically. 7.2.2 On Windows XP / 7 Under Windows XP, it is necessary to install the USB driver manually. To do this, connect the USB cable to the router and on the computer.
  • Page 52: Terminal Installation (Tera Term)

    User Manual To finish, check « search the best pilotes in location » and specify the location of the file « Linux_acm_inf ». This file is available with the documentation of router. Click on « Next ». 7.3 Terminal installation (Tera Term) To view information from the USB communication, a terminal must be used.
  • Page 53 User Manual Figure 68 Start Tera Term configuration Select « Serial » and in port the nom of device connected. Under Windows 8, the device will be appear with name « ELMO GMAS » Under Windows 7/XP, the device will be appear with name « g_serial » The terminal configuration is made by clicking on "Settings"...
  • Page 54 User Manual END OF DOCUMENT Centre Commercial Plein Centre Allée du Quercy 31770 Colomiers France +33(0)5 34 28 12 24 support@occitaline.com Release EN 0.93 Page 53/53...