Do you have a question about the CardioTech BP6T and is the answer not in the manual?
Questions and answers
Rosa Ochoa
March 25, 2025
How to update the date?
1 comments:
Mr. Anderson
May 14, 2025
To update the date on the Ozeri BP6T:
1. Make sure the unit is off. 2. Press and hold the “SET” button for 3 seconds to enter Time Setting Mode. 3. The time format will blink first. Use the “MEM” button to change between 12H and 24H formats. 4. Press “SET” again to move to the time and date settings. 5. Use the “MEM” button to adjust the values. 6. Press “SET” to confirm each setting and move to the next.
Page 1
CardioTech BP6T Blood Pressure Monitor User Manual Wrist Type Thank you for purchasing this Ozeri Blood Pressure Monitor. Please read this manual thoroughly before first use, and keep this manual handy for future reference. 6755 Mira Mesa Blvd. Suite 123-239 San Diego, CA 92121 sales@ozeri.com...
TABLE OF CONTENTS TABLE OF CONTENTS Before Using Your Blood Pressure Monitor Technical Information Introduction Specifications Important Safety Information Accessories Health and Blood Pressure Values EMC Guidance Suggestions Before Measuring Warranty Customer Support Getting to Know Your Unit LCD Full Display Device Components &...
INTRODUCTION IMPORTANT SAFETY INFORMATION Thank you for purchasing the Ozeri BP6T Fully Automatic To ensure the correct use of this product, basic safety Blood Pressure Monitor. This device uses the oscillometric measures should always be followed. Read all information in...
Page 4
Dispose device, components optional ● accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution. Use only Ozeri authorized parts and accessories. Parts and ● accessories not approved for use with the device may...
HEALTH AND BLOOD PRESSURE VALUES SUGGESTIONS BEFORE MEASURING What is the standard blood pressure classification? CAUTION This device refers to a blood pressure classification published by the American Heart Association (AHA). Only a physician can tell you your normal blood pressure range and the point at which you are at risk.
CHARGING YOUR DEVICE PROGRAMMING THE UNIT Setting Time Format, Time, Date and Measurement Unit 1. The BP6T blood pressure monitor uses a built-in rechargeable It is important to set the date and time before using your blood pressure lithium-ion battery, with a capacity of 420 mAh. 2.
PROGRAMMING THE UNIT (CONTINUATION) APPLYING THE CUFF AND POSITIONING Correct Measurement Position 4. Press “SET” to confirm the [HOUR]. The proceed to program the [MINUTE]. In order to get an accurate reading, sit upright in a chair and rest your left elbow on the table.
MEASURING YOUR BLOOD PRESSURE MEASURING YOUR BLOOD PRESSURE (CONT) Starting a Measurement Important Instructions: 1. After correctly positioning cuff, press START/STOP button to turn on the device. The user icon Ensure that you are not eating, talking, laughing or smoking for at least 5 START ●...
ABOUT BLOOD CIRCULATION AND PRESSURE IRREGULAR HEARTBEAT? An irregular heartbeat is defined as a heartbeat that varies by Blood circulation is responsible for supplying the body with 25% from the average of all heartbeat intervals while the unit is oxygen from the lungs. During each heartbeat cycle, the blood measuring the systolic and diastolic blood pressure.
IRREGULAR HEARTBEAT? (CONT) WHAT IS ARRHYTHMIA? If an irregular rhythm is detected more than twice during A heartbeat is stimulated by electrical signals that cause the measurement, the irregular heartbeat symbol with three heart to contract. Arrhythmia is a condition where the h e a r t s w i l l a p p e a r o n t h e d i s p l a y a l o n g w i t h t h e heartbeat rhythm is abnormal due to flaws in the bio-electrical measurement results.
RECALLING RECORDS DELETING RECORDS CAUTION Recalling Records in Memory This device features enhanced memory to store up to 399 records for 3 different users. The most recent reading is by default shown 1. When the monitor is off, press “MEM” button to access the memory. The first, following by the next most recent reading.
Measurement error. part of this device to water. then measure again. Relax and retake the Eexx A calibration error measurement. If the occurred. problem persists, contact support@ozeri.com for further assistance. Refer to the warranty for contact information and return instructions.
Atmospheric pressure: 50kPa to 106kPa use of the Ozeri Blood Pressure Monitor other than for its intended use or Measurement perimeter as instructed above and in the User Manual.) About 13.5cm - 21.5cm...
Ozeri. Please pack carefully to avoid damages affect this equipment and should be kept at least a in transit. Under this warranty, Ozeri will repair or replace distance d = 3,3m (11ft) away from the equipment.
WARRANTY INFORMATION CUSTOMER SUPPORT This warranty is not transferable. Ozeri is not responsible in Ozeri Customer Service Customer service: 1-877-299-1296 or any way for damages, losses or inconveniences caused by equipment failure caused by user negligence, abuse, or Email: support@ozeri.com use not in accordance with the “User Guide”...
Need help?
Do you have a question about the CardioTech BP6T and is the answer not in the manual?
Questions and answers
How to update the date?
To update the date on the Ozeri BP6T:
1. Make sure the unit is off.
2. Press and hold the “SET” button for 3 seconds to enter Time Setting Mode.
3. The time format will blink first. Use the “MEM” button to change between 12H and 24H formats.
4. Press “SET” again to move to the time and date settings.
5. Use the “MEM” button to adjust the values.
6. Press “SET” to confirm each setting and move to the next.
This answer is automatically generated