Middle Atlantic Products USC-6R Instruction Sheet

Middle Atlantic Products USC-6R Instruction Sheet

Universal sequencing controller for mpr modular power system

Advertisement

Quick Links

Universal Sequencing Controller
For MPR Modular Power System
USC-6R
120V 12A 60Hz
THANK YOU
Thank you for purchasing the Universal Sequencing Controller For MPR Modular Power
System.
PRODUCT FEATURES
- Provides six-step sequencing to remote switchable modules via 12 volt DC and/or dry contact
switch closure
- Adjustable start delay times
- Adjustable sequence intervals
- Up to three units may be daisy-chained together for a total of 18 steps of sequencing
- Requires momentary contact closure (single pole, double throw, center off)
Instruction Sheet
USC-6R
6
5
4
1.5A 125V
12VDC
12VDC
FRONT VIEW
3
2
1
USC Remote
12VDC
12VDC
12VDC
12VDC
Switch Only
Start Delay
0-1-2-3
OUTPUTS
REAR VIEW
ON
MASTER
OFF
Remote
Common
Up
Down
Start Delay Switch Settings
0 - Single Unit
1 - 1st Unit of 3
2 - 2nd Unit of #
3 - 3rd Unit of 3
Middle Atlantic Products
I-00004
Rev K

Advertisement

loading

Summary of Contents for Middle Atlantic Products USC-6R

  • Page 1 0-1-2-3 1 - 1st Unit of 3 2 - 2nd Unit of # 3 - 3rd Unit of 3 OUTPUTS Middle Atlantic Products REAR VIEW THANK YOU Thank you for purchasing the Universal Sequencing Controller For MPR Modular Power System.
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS! DANGER HAZARDOUS VOLTAGE/DANGER HAUTE CONSERVER CES INSTRUCTIONS! TENSION The lightning flash with the arrowhead symbol, within an • Contains switched receptacle(s). To reduce risk of shock , disconnect the equilateral triangle is intended to alert the user to the device from the power source before servicing any connected presence of uninsulated dangerous voltage within the equipment...
  • Page 3: Connections, Controls And Indicators

    3 - 3rd Unit of 3 OUTPUTS Middle Atlantic Products The Master Power Switch Circuit Breaker (with indicator light): Switches power from the line cord to the rest of the unit and additionally provides overload protection (rated at 15 Amps at 120 VAC). Also provides “power on” indication via the illuminated switch actuator. Master Switch is enhanced by a switch guard to prevent accidental power switching.
  • Page 4 CONNECTIONS, CONTROLS AND INDICATORS (Continued) Green LED “Ready” Indicator: This LED, located on the front panel, will be illuminated when the master power switch is turned on. When a start delay function is selected via the “start delay switch”, this light will blink indicating that the unit has received a command to initiate a sequence up or down. The LED will blink for the duration of the selected start delay time (from the time sequence is initiated to the time first channel output is energized).
  • Page 5 The remote terminal block on the rear of the USC-6R has two functions: 1. Enables the interconnection of up to three USC-6R’s to function as a single 18 step unit. Allows up to three USC-6R sequencer to operate under control of the system switch on any sequencer in the group (dependent on delay start switch settings).
  • Page 6 WARRANTY Middle Atlantic Products (the "Company") warrants the USC-6R Universal Sequencing Controller For MPR Modular Power System to be free from defects in material or workmanship under normal use and conditions for a period of (3) years from the date of shipment by the company.