Advertisement

Quick Links

E
I
R
4
1
0
-
2
S
F
P
-
T
E
I
R
4
1
0
-
2
S
F
P
-
T
U
s
e
r
M
a
n
u
a
l
U
s
e
r
M
a
n
u
a
l
Manual Documentation Number EIR410-2SFP-T– 0109m
www.bb-elec.com
www.bb-europe.com

Advertisement

Table of Contents
loading

Summary of Contents for E-LINX EIR410-2SFP-T

  • Page 1 Manual Documentation Number EIR410-2SFP-T– 0109m www.bb-elec.com www.bb-europe.com...
  • Page 2 All Brand names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder Manual Documentation Number EIR410-2SFP-T – 0109m www.bb-elec.com...
  • Page 3: Table Of Contents

    Mounting Installation....................... 13 DIN-Rail Mounting ....................... 13 Wall or Panel Mount Plate Mounting ................15 Hardware Installation ......................16 Installation Steps ......................16 Network Application ........................ 17 Troubleshooting........................18 Technical Specification......................19 Manual Documentation Number EIR410-2SFP-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 4: Introduction

    Introduction Introduction The EIR410-2SFP-T is an industrial DIN mount, unmanaged 10 port Ethernet switch with Gigabit capability. It has (8) 10/100 copper Ethernet ports and (2) Gigabit Combo ports that support copper or SFP module connections. Features • System Interface/Performance...
  • Page 5: Package List

    Introduction Package List • (1) EIR410-2SFP-T, 10 Port Gigabit Industrial Ethernet Switch • (1) Quick Start Guide • (1) CD ROM with User Manual • (2) Wall Mounting Bracket and Screws Manual Documentation Number EIR405-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 6: Hardware Description

    Hardware Description Physical Dimension (W x D x H) is 72mm x 105mm x 152mm (2.8 x 4.1 x 6.0 inches) Front Panel The Front Panel of the EIR410-2SFP-T is shown below. Manual Documentation Number EIR410-2SFP-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 7: Top View

    Hardware Description Top View The top panel view of the EIR410-2SFP-T is equipped with one terminal block connector that consists of two 12 to 48 VDC power inputs and the fault alarm output. Manual Documentation Number EIR405-T – 0109m www.bb-elec.com...
  • Page 8: Led Indicators

    Hardware Description LED Indicators Status Meaning Green Power 1 is active PWR1 No power at input 1 Green Power 2 is active PWR2 No power at input 2 Power 1 or Power 2 is inactive Fault Power 1 and 2 are both functional, or no power is applied Green...
  • Page 9: Ports

    Note “+” and “-” signs represent the polarity of each wire pair. All copper ports on the EIR410-2SFP-T support automatic MDI/MDI-X operation, you can use straight-through cables (See Figure below) for all network connections to PCs or servers, Manual Documentation Number EIR405-T – 0109m www.bb-elec.com...
  • Page 10 • 2 Gigabit Copper/SFP (mini-GBIC) combo ports: The EIR410-2SFP-T has two auto-detect Giga ports—copper/Fiber combo ports. The Gigabit Copper (10/100/1000T) ports should use Category 5e or above UTP/STP cable for connection. The SFP slots support dual mode which can switch the connection speed between 100 and 1000Mbps.
  • Page 11 Hardware Description SFP slot until a click is heard. With the SFP module (fiber optic connection), the switch can transmits speed up to 1000 Mbps and you can prevent noise interference from the system and get extended transmission distance, depending on the SFP module used. Note The SFP/Copper Combo port can’t both be used at the same time.
  • Page 12 Hardware Description Make sure the module is aligned correctly and then slide the module into the SFP slot until a click is heard. Transceiver Inserted Second, insert the fiber cable into the transceiver. LC connector to the transceiver Manual Documentation Number EIR405-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 13: Cabling

    Hardware Description To remove the LC fiber cable and SFP transceiver, follow the steps below: First, press the upper side of the LC connector down and pull it out before releasing. Remove LC connector Second, swivel the metal latch away from the switch and pull the transceiver out. Pull out from the transceiver Cabling Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable.
  • Page 14: Wiring The Power Inputs

    Hardware Description Wiring the Power Inputs Follow the steps below to insert the power wire. 1. Insert the positive and negative wires into the V+ and V- contacts on the terminal block connector. 2. Tighten the wire-clamp screws to prevent the wires from becoming loose. Manual Documentation Number EIR405-T –...
  • Page 15: Wiring The Fault Alarm Contact

    Hardware Description Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as shown below. If one of the power sources fails a fault will be detected causing the circuit to open. Insert the wires into the fault alarm contact (No.
  • Page 16: Mounting Installation

    Then follow the steps below to hang the switch onto a DIN rail. Use the screws to screw the DIN rail clip onto the switch. To remove the DIN rail clip, reverse step 1. Manual Documentation Number EIR410-2SFP-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 17 Technical Specification First, insert the top of DIN rail clip onto the piece of DIN rail track. Then, lightly push the bottom of the switch so it can snap the rest of the way onto the DIN rail track. Check that the switch is held tightly to the DIN rail track. To remove the switch from the track, reverse the steps above.
  • Page 18: Wall Or Panel Mount Plate Mounting

    Technical Specification Wall or Panel Mount Plate Mounting Follow the steps below to mount the switch with the wall mount plate. 1. Remove the DIN rail clip from the switch; loosen the screws to remove the DIN rail clip. 2. Place the wall mount plate on the rear panel of the switch. 3.
  • Page 19: Hardware Installation

    Industrial switch will light up when the cable is connected with the network device. Please refer to the LED Indicators section for LED light indication. 7. When all connections are set and LED lights all show in normal, the installation is complete. Manual Documentation Number EIR410-2SFP-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 20: Network Application

    Network Application Network Application The diagram below shows a typical switch installation for the EIR410-2SFP-T. Manual Documentation Number EIR410-2SFP-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 21: Troubleshooting

    • If the switch LED’s represent normal operating mode and the cable connections are correct and no data is transmitted or received through the switch, contact your Network Administrator for network configuration and status help. Manual Documentation Number EIR410-2SFP-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 22: Technical Specification

    10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable EIA/TIA-568 100-ohm (100m) 100Base-TX: 2-pair UTP/STP Cat. 5/5E cable Network Cable EIA/TIA-568 100-ohm (100m) 1000Base-TX: 2-pair UTP/STP Cat. 5E/6 or above cable EIA/TIA-568 100-ohm (100m) Manual Documentation Number EIR410-2SFP-T – 0109m www.bb-elec.com www.bb-europe.com...
  • Page 23 Technical Specification Multi-mode 50/125µm or 62.5/125µm Optical cable Single-mode 9/125µm Back-plane 5.6Gbps (Switching Fabric) Packet throughput 8.3Mpps at 64bytes ability 12 to 48 VDC Power Supply Redundant power with reverse polarity protection and removable terminal block Power consumption 6.76 Watts Install DIN rail or panel/wall-mount Operation Temp.
  • Page 24 Technical Specification Safety CE/EN60950-1 IEC60068-2-32 (Free fall) Stability testing IEC60068-2-27 (Shock) IEC60068-2-6 (Vibration) Manual Documentation Number EIR405-T – 0109m www.bb-elec.com www.bb-europe.com...