Sun System PK 2.15 Installation And Operation Manual

Solar collectors flat-plate pk series; evacuated-tube vtc series

Advertisement

SUNSYSTEM solar collectors
FLAT-PLATE COLLECTOR РК series
EVACUATED-TUBE COLLECTOR VTC series
TECHNICAL PASSPORT
INSTALLATION and OPERATION MANUAL
v0.1
model:
serial number:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PK 2.15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sun System PK 2.15

  • Page 1 SUNSYSTEM solar collectors FLAT-PLATE COLLECTOR РК series EVACUATED-TUBE COLLECTOR VTC series TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL v0.1 model: serial number:...
  • Page 2: Table Of Contents

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TABLE OF CONTENTS Explanation of symbols and safety instructions ..........3 1.1. Explanation of symbols ..................3 1.2. Requirements to collector installation place ............3 1.2.1. Instructions to collector installer ................. 3 1.2.2.
  • Page 3: Explanation Of Symbols And Safety Instructions

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 1. EXPLANATION OF SYMBOLS AND • local construction regulations on SAFETY INSTRUCTIONS installation on building – mass of the 1.1. Explanation of symbols system to comply with the building structure. Important CAUTION! • regulations and norms concerning recommendation warning safety installation and operation of solar...
  • Page 4: Instructions To Installation User

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL FIRE HAZARD through contact of accumulated waste (dry leaves, plastic bags, paper) with the  hot parts of the collectors. We recommend the regular inspection and cleaning of collector installation sites.
  • Page 5: Protective Heat-Tempered Solar Glass Durasolar® P

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 2.3. Protective heat-tempered solar glass 3. DESCRIPTION OF VTC TYPE Durasolar® P+. EVACUATED - TUBE COLLECTOR 3.1. Evacuated tube. Absorber coating Diagram 3. Solar-grade heat tempered glass Diagrаm 5 Durasolar® P+. The glass used in Evacuated tubes are two concentrically SUNSYSTEM flat-plate...
  • Page 6: Temperature Sensor

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL PK: Protective plastic corners are fit on each panel collector frame to protect it from rubbing against another collector frame.Panel collectors are stacked on each other horizontally on a pallet. Dimensions of pallets match dimensions of the collectors.
  • Page 7 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Table 1 РК type Collector VTC type Collector Check whether protective glazing is Check to assure that evacuated tubes are all intact and the intact bottom of each tube is still silver-colored. If a tube has a white clear bottom, that means it is damaged and should be replaced.
  • Page 8: Installation

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 6. INSTALLATION Table 2 Collector application Recommended Must be performed by an autho- mounting angle  rized service technician/service Domestic Hot Water / shop for such operations. 30°÷45° DWG+pool DANGER of slipping.
  • Page 9: Installation Of Flat-Plate Collector Рк

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 6.1. Installation of PK type flat-plate Mounting Instructions. collector Adjust the support angle as needed. Place the collector on the support. Fix the collector to support using the clamping clips. Make sure all connections are properly secured and will not loosen under harsh weather conditions.
  • Page 10: Installation Of Evacuated-Tube Collector Vtc

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 6.2. Installation of VTC type evacuated- placing the manifold on the top and the tube collectors. rubber protectors in the bottom part. Evacuated tube collectors are mounted Such collectors have vertical orientation. Diagram 13 Collectors VTC type are mounted on specially designed support systems, adapted to different roof slopes.
  • Page 11 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 6.2.2. Inclined roof VTC type collector other the two side rails F. For each rail put two silicone pads K, in installation places where the bar rests on the roof tile. Install the two side rails F to fixing straps B.
  • Page 12: Connecting Multiple Collector Series

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Step 4. Take the plastic tube hangers D. Their number is equal to the number of pipes. Place them in the holes on the bottom rail H. /Diagram 20/ Step 5.
  • Page 13: Connect The Collector To The Hot Water System And / Or Central Heating

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 7. CONNECTING THE COLLECTOR TO Table 3 Number of collectors in one array DOMESTIC HOT WATER/CENTRAL HEATING SYSTEM Number of col- Number of collec- lectors PK type in tors VTC type in one array: one array: 7.1.
  • Page 14: Manifold Connections

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL In areas with heavy snowfalls it is a device for heat dissipation or to add recommended to further strengthen the more users to the hot water circuit in the collector support fixation to the building summer (swimming pool or other similar structure, as well as frequent inspection...
  • Page 15: Stagnation Temperature

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Fixing the fittings: at which point hot water will be dumped - Always use two opposing spanners when from the system. If a PTRV is not installed tightening the compression fittings. Do on the collector, steam will form in the not twist the copper pipe (inlet/outlet) header.
  • Page 16: Installation Of Safety Valve For Temperature

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL should be coated with a thick layer of without effort. thermal paste and inserted into the Collector working (operating) pressure sensor sleeve to the full depth. If the fit is should be secured using a pressure relief too loose, slide a piece of copper plate or valve at 6 bars.
  • Page 17: Connection Diagrams

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 7.8. Connection diagrams Must be performed by an autho-  rized service technician/service shop for such operations. Diagram 25. Connection of Flat-plate collector РK to solid fuel boiler WBS, combi tank KSC2 and three-way valve...
  • Page 18 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Diagram 26. Connection of Evacuated-tube collector VTC to solid fuel boiler WBS, combi tank KSC2 and three-way valve...
  • Page 19 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Diagram 27. Connection of Flat-plate collector РK to solid fuel boiler WBS, solar water tank SON, buffer tank P and three-way valve...
  • Page 20 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Diagram 28. Connection of Flat-plate collector РK to solid fuel boiler WBS, solar water tank SON, buffer tank P and three-way valve...
  • Page 21: Commissioning

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 8. COMMISSIONING - Checkup heat carrier fluid, replacement thereof. Must performed  9.2. Cleaning of collectors from dust authorized service technician/ deposits, fallen dry leaves and twigs service shop for such operations. Keeping the collector surface (type PK or VTC) clean is a prerequisite for good Before commissioning of solar collector performance.
  • Page 22 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL the products it manufactures shall - Improper installation or use as well be free from defects in materials and as changes especially if they are not workmanship which can prevent from made by authorized after-sale service normal operation under proper and personnel of NES Ltd.
  • Page 23: Technical Features

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Ltd. in the region. 10.3.4. If on customer’s request, and For this purpose the claimant shall fill when there is reason for urgency, out a claim form; the latter shall be customer demands immediate accompanied by the document proving replacement of the product he has the purchase of the collector (invoice)
  • Page 24 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Table 6. Technical parameters of PK type Flat-plate collector SUNSYSTEM SUNSYSTEM STANDARD SELECT РК 2.15 РК 2.7 РК 2.0 РК 2.15 РК 2.5 РК 2.7 Width L1 mm 1020 1248 1020...
  • Page 25: Technical Features Of Evacuated-Tube Collector Vtc

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 11.2. Technical features of VTC type Evacuated-tube collector Diagram 30. Elements of VTC type Evacuated-tube collector 1. Manifold 2. Inlet/Outlet sleeve 3. Evacuated glass tube 4. Holder and protector of evacuated glass tube 5. Frame of VTC collector 6.
  • Page 26 TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL Table 7. Technical parameters of VTC type Evacuated-tube collector Model VTC 15 VTC 20 VTC 30 Number of evacuated tubes pcs. Height H mm 1980 1980 1980 Width L / Thickness D mm 1190/125 1570/125 2300/125...
  • Page 27: Recycling

    TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL 12. RECYCLING AND WASTE DISPOSAL According to Directive 2002/96/EC on waste electrical and electronic equipment 12.1. Recycling of collector packaging (WEEE) they are to be disposed of outside Parts of the packaging made of wood or the normal flow of solid domestic waste.