PULSE Pro
User Manual
PULSE User Manual
WARNINGS

Advertisement

Table of Contents
loading

Summary of Contents for NormaTec PULSE PRO

  • Page 1 PULSE Pro User Manual PULSE User Manual WARNINGS...
  • Page 2: Table Of Contents

    Table of Contents Warnings Labels Indications for Use, Risks and Benefits of the NormaTec Recovery System Illustrations Operating Instructions Setup the System Choose your Attachment Adjust the Mode Adjust the Intensity Adjust the Session Time Start the Session What to Expect...
  • Page 3: Warnings

    • Keep the open ports of the Control Unit, NormaTec Hose interconnect and Power Jack free of debris • If the power supply or power cord is damaged, the PULSE PRO Control Unit is dropped or damaged, liquid is spilled on the system, or if the system does not operate normally when the operating instructions are followed, turn the system off by pushing the PULSE PRO Control Unit’s...
  • Page 4 • This product contains a lithium ion battery. Dispose of this product in accordance with local regulations. • Do not use the Control Unit air output or NormaTec Hose to direct pressurized air towards your eyes, nose, mouth, or ears. Doing so may lead to serious injury.
  • Page 5: Labels

    Labels The following labels and symbols appear on the control unit, garments, and/or packaging. SYMBOL DESCRIPTION LOCATION IP21 Degree of protection against ingress of water On base of control unit Read instructions before use On base of control unit Read instructions before use On attachment tag Level of protection type BF equipment On base of control unit...
  • Page 6 Warning symbol – Used to identify a hazard that may lead to death or serious injury. ** * Note (Precaution) – Used to identify a hazard that may result in minor or moderate injury to the user or patient, or damage to the equipment or other property. PULSE PRO User Manual LABELS...
  • Page 7: Indications For Use, Risks And Benefits Of The Normatec Recovery System

    Risks and Benefits of the Normatec Recovery System The risks and benefits of using the NormaTec PULSE PRO Recovery System are the same as having a massage. If the massage feels uncomfortable, you can reduce the intensity or stop the session.
  • Page 8: Illustrations

    Illustrations PULSE PRO CONTROL UNIT FLUSH MODE INTENSITY LEVEL 8 SESSION TIME 30:00 ZONE BOOST START 1. Power Button 2. Touchscreen 3. Air Outlet and Power Inlet PULSE PRO User Manual ILLUSTRATIONS...
  • Page 9 NORMATEC HOSE 1. Junction Box Air Outlet 2. Junction Box Air Outlet 3. Junction Box 4. Blocking Plug (on the underside of the Junction Box) 5. NormaTec Hose Connector (connects to PULSE PRO Control Unit) ILLUSTRATIONS...
  • Page 10 LEG ATTACHMENT (Single person use only.) 1. Attachment Connector 2. Zones ARM ATTACHMENT (Single person use only.) 1. Attachment Connector 2. Zones PULSE PRO User Manual ILLUSTRATIONS...
  • Page 11 HIP ATTACHMENT (Single person use only.) 1. Attachment Connector 2. Zones POWER SUPPLY 1. Barrel Connector 2. Wall outlet plug ILLUSTRATIONS...
  • Page 12: Operating Instructions

    PULSE PRO Control Unit and an electrical outlet. Step 2: Connect the long end of the NormaTec Hose to the Air Outlet on the front of the PULSE PRO Control Unit. The connector can only be inserted in the correct orientation. Press the connector firmly into the PULSE PRO Control Unit until you hear an audible “click.”...
  • Page 13: Choose Your Attachment

    Home Screen Level Adjustment Screen Time Adjustment Screen CHOOSE YOUR ATTACHMENT Select the attachment you are using with the system by tapping on the attachment graphic on the Home Screen. Tap an attachment to select it, and then tap the Back Button to return to the Home Screen.
  • Page 14: Adjust The Intensity

    Continuous Mode can be enabled allowing the system to run until the session is manually stopped. To enter Continuous Mode, tap the increase time button until the time shows 2 hours 55 minutes and then tap one more time. To exit Continuous Mode, tap the down arrow. PULSE PRO User Manual OPERATING INSTRUCTIONS...
  • Page 15: Start The Session

    Power Button, and disconnect the hose from PULSE PRO Control Unit. To disconnect connectors from the Junction Box or the PULSE PRO Control Unit, push on the button on the top of the NormaTec Hose Connector/Attachment Connectors while pulling away from the Junction Box/PULSE PRO Control Unit.
  • Page 16: To Turn Off The Device

    To disconnect connectors from the Junction Box or the PULSE PRO Control Unit, push the button on the top of the NormaTec Hose Connector/Attachment Connectors while pulling away from the Junction Box/PULSE PRO Control Unit. TO TURN OFF THE DEVICE To turn off the system, press the Power Button and confirm that the green power LED is shut off.
  • Page 17: Options

    Options ADJUSTING REST TIME Adjust the Rest Time by tapping on the Gear Icon at the bottom of the Home Screen, in the center. Tap on the Rest Time Button and then tap on the up and down arrows to adjust the rest time between 15 and 90 seconds.
  • Page 18: Utilities

    Reset the device to factory settings by tapping on the Wrench Icon at the bottom of the Home Screen, on the right. Tap on the Default Settings Button and then tap YES. This option can only be adjusted before a session starts. PULSE PRO User Manual UTILITIES...
  • Page 19: Statistics

    Statistics PRESSURE AND TIME View the current settings for pressure and time by tapping on the Graph Icon at the bottom of the Home Screen, on the left, and then tapping on the Zone: Pressure & Time Button. Tap on the Back Button twice to return to the Home Screen when complete.
  • Page 20: Caring For The System

    • Do not dry clean! MAINTAINING THE SYSTEM The NormaTec PULSE PRO Recovery Control Unit, NormaTec Hose, Power Supply, and Attachments (legs, arms, or hips) require no routine maintenance or service except for the care in this section. STORING THE SYSTEM Store NormaTec PULSE PRO Recovery Control Unit, NormaTec Hose, Power Supply, and Attachments (legs, arms, or hips) in a clean, dry location.
  • Page 21: Technical Information

    Only use the AC-DC Adapter Model Number 50-00048 provided with the system. Using a different adapter may cause the system to not operate correctly. INPUT: 100-240V .6-.8 A 50/60 Hz per NormaTec Model # 50-00048 OUTPUT: DC Minimum 15 Watt per NormaTec Model # 50-00048 TEMPERATURE (OPERATING): +41°...
  • Page 22 The information contained in this section (such as separation distances) is in general specifically written with regard to the NormaTec PULSE PRO. The numbers provided will not guarantee faultless operation but should provide reasonable assurance of such. This information may not be applicable to other medical electrical equipment;...
  • Page 23 ELECTROMAGNETIC IMMUNITY This equipment is intended for use in the electromagnetic environment specified below. The user of this equipment should assure that is used in such an environment. COMPLIANCE IMMUNITY IEC 60601-1-2 TEST ELECTROMAGNETIC LEVEL (OF AGAINST LEVEL ENVIRONMENT THIS DEVICE) Electrostatic Contact Discharge: ±...
  • Page 24 RF compliance level above, the equipment should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the equipment. PULSE PRO User Manual ELECTROMAGNETIC COMPATIBILITY...
  • Page 25 Recommended Separation Distances BETWEEN PORTABLE AND MOBILE RF COMMUNICATIONS EQUIPMENT AND THE EQUIPMENT RATED SEPARATION DISTANCE ACCORDING TO FREQUENCY OF TRANSMITTERS MAXIMUM IN METERS OUTPUT 150 kHz – 80 MHz 80 MHz to 800MHz 800 MHz to 2.5 GHz POWER OF d=1.2/V1]√P d=1.2/V1]√P d=2.3√P...
  • Page 26 • Equipment not suitable for use in the presence of a flammable anesthetic mixture with air, or with oxygen, or nitrous oxide • Equipment not suitable for use with oxygen or oxygen enriched atmospheres • Continuous operation PULSE PRO User Manual EQUIPMENT CLASSIFICATION...
  • Page 27: Troubleshooting

    Check connections and for leaks in the NormaTec Hose or attachment. If no leak is found, call NormaTec. Low Battery Battery needs to be Plug in the Control Unit to charge the battery. charged Call NormaTec Customer Service at 866.658.5896 if further assistance is needed. TROUBLESHOOTING...
  • Page 28: Warranty Information

    NormaTec. In the event of any such defect occurring during the warranty period, NormaTec will, at its option, (a) correct the defect by repair or by replacement of the applicable part or component that fails as a result of such defect, without charge for parts and labor; or (b) replace the device with one of the same or then current design.
  • Page 29: Return Policy

    6. All partial or full refunds will be posted to the credit card used for purchase. 7. NormaTec is not responsible for items lost or damaged during shipping. RETURN SHIPPING DIRECTIONS Step 1: Contact us at 866.658.5896 or support@normatecrecovery.com to obtain a Return Merchandise Authorization (RMA) number.
  • Page 30 NormaTec Recovery NormaTec Recovery NormaTecRecovery.com | 866.658.5896 NormaTec Recovery @NTrecovery @NTrecovery NormaTec Recovery NormaTec Recovery NormaTec Recovery @NTrecovery...