TRE i SYSTEMS IT-400 Manual

7 zone hardwire control panels it-400 series

Advertisement

Quick Links

ENGLISH
20.0
VERSION IT 400 D/K
ON
OFF
J8
12345678
12345678
F1 = 1 A
F2 = 1 A
PC board
Auxiliary ou-
Dip-switch A
Dip-switch B
protection
tputs protection
Normally operation
Volt free relay contacts
TS1
+ 12 Vdc to Terminal 14
Reset factory condition
1 2 3 4 5 6 7 8 9 10 11
12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
NO C NC NC NO C NO C NC
NC NO C NO C NC
12 Vdc auxiliary output
Outdoor siren relay
Fire alarm relay
Panic alarm relay
Indoor siren relay
Relay with selectable operation
30 31 32 - RS 485 BUS, serial interface for connecting expansions and programming
peripherals.
33 34
- Normally closed Remote key input for total arming (IT-400 D)
35 36 37 - Not present on IT-400D.
IT-400 K only
33
- Negative
34
- Remote electronic key input (see page 10).
35
- Output for remote LED that indicates control panel armed day position.
This is located on the remote electronic key base. (see page 10).
-
36
Output for remote LED that indicates alarm memory.
This is located on the remote electronic key base (see page 10).
37
- Output for remote LED that indicates control panel armed for night functions.
This is located on the remote electronic key base (see page 10).
38
- Negative output for telephone dialler that signals burglary and tamper
(Imax 100 mA). This output remains active for one second.
39
- Negative output for "Unit ON" signalling - (Imax 100 mA).
This output remains active during the ON status.
40 42
- Power input for control panel 19 Vac.
41
- NOT USED
Page 20
19 Vac
42
41
GND
19 Vac
40
F3 = 1 A
F4 = 1 A
39
Unit ON
Battery polarity
Short circuit
38
Negative impulse
inversion
transformer
D
37
C
36
Electronic remote key
B
35
(IT-440K version)
Remote key
A
34
34
33
33
IT-400 / 400D version
Negative
30 31 32
Bus RS485
L1 L2
L3 L4
L5 L6
L7 L8
Normally closed lines
GND
(NC)
TX
RX
Volt free relay contacts
L5 = Not used
L6 = Fire alarm line
L7 = Panic alarm line
L8 = 24 hours antitamper line
IT-400 series instruction manual
3 models IT-400/IT-400 K/IT-400 D
(NC)
Summary
1.0. Description ...................................................................................................... 2
2.0. Installation ....................................................................................................... 3
3.0. Terminal block connections ........................................................................... 4
4.0. Mains power connection ................................................................................. 7
4.1.
4.2.
5.0. Front panel ....................................................................................................... 8
6.0. Zone description ............................................................................................. 9
6.1 Balance resistor connection ........................................................................ 9
7.0. Key
7.1 Electronic key ............................................................................................ 10
7.2. Remote receptacle installation .................................................................... 10
7.3. Electronic key sabotage ............................................................................. 10
8.0. Mechanical switch lock key ............................................................................ 11
9.0. Maintenance mode .......................................................................................... 11
10.0. Programming ................................................................................................... 12
11.0. User code ......................................................................................................... 13
12.0. Self learning of the electronic key ................................................................. 13
13.0. By-passing zones ............................................................................................ 14
14.0. Total arming (ON mode) ................................................................................. 15
15.0. Partial arming (NIGHT mode) .......................................................................... 16
16.0. Disarming (DAY mode) ................................................................................... 17
17.0. Low battery alert .............................................................................................. 18
18.0. Reset to factory code ...................................................................................... 18
19.0. Technical characteristics ................................................................................ 19
20.0 Connected Version IT 400 D/K ........................................................................ 20
7 zone hardwire control panels
Mains power fuse change ........................................................................ 7
Ground connection ................................................................................... 7
................................................................................................................. 9
Page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IT-400 and is the answer not in the manual?

Questions and answers

Summary of Contents for TRE i SYSTEMS IT-400

  • Page 1: Table Of Contents

    4.0. Mains power connection ................. 7 peripherals. 4.1. Mains power fuse change ................ 7 33 34 - Normally closed Remote key input for total arming (IT-400 D) 4.2. Ground connection ................... 7 5.0. Front panel ....................... 8 35 36 37 - Not present on IT-400D.
  • Page 2: Description

    Dimensions: 275x220x80 mm (ABS container) 310x315x80 mm (metallic container) The control panels of the IT-400 series may be armed by means of a mechanical key (IT-400), an electronic key (IT-400 K) or keypad (IT-400 D). Remote arming key is optional.
  • Page 3: Installation

    NOTE: When the panel has no mains and no battery voltage connected, and you power it, the IT-400 will go to the status of the panel KEY switch, IT-400K and IT-400D will 2) Put to ON dip 1 of dip-switch A.
  • Page 4: Terminal Block Connections

    L3 L4 L5 L6 L7 L8 To cancel the alarm memory in IT-400 D / IT-400K, press any key on the keypad or change Normally closed lines NO C NC NC NO C NO C NC NC NA C NO C NC...
  • Page 5 IT-400 : Rotate the key to “NIGHT” position (Terminals 12 to 17) alarm relays for the pre-programmed time. IT-400 K : Insert the key into the key holder for more than 5 sec. With the control panel disarmed, triggering this line will cause: IT-400 D : Digit the access code on a keypad and press “...
  • Page 6 - The Buzzer must be connected from +12 Vcc and buzz terminal Procedure: 34 35 - Normally closed Remote key input for total arming used on (IT-400 & IT-400D) only IT-400 : Rotate the key in “ON” position. 36 37 38 - Not used on IT-400 IT-400 K : Insert the key into the key receptacle for less than 5 sec.
  • Page 7: Mains Power Connection

    At the end of configuration, switch the control panel to the "DAY" mode for memorization. IT-400 / IT-400 K - Turn the key of the control panel to the "DAY" position. It is important to have a good ground connection to avoid electrical disturbances to the control panel.
  • Page 8: Front Panel

    If all the 9 memory locations have been occupied, the panel will not accept new 2) Model IT-400 K : Electronic key for arming and disar- keys. In this case the master key (as explained in paragraph 18.0.) and all the ming the control panel is supplied with the unit.
  • Page 9: Zone Description

    10.0. PROGRAMMING 6.0. ZONE DESCRIPTION The series IT-400 control panels (It-400, IT-400 K, IT-400 D) have 7 zones in total of which L1 L4 are burglary alarm zones and L6, L7, L8 are Fire, panic and anti-sabotage. With the control panel in maintenance mode it is possible to program it using dip-switches A...
  • Page 10: Electronic Key

    7.1. ELECTRONIC KEY (IT-400 K only) 8.0. MECHANICAL SWITCH LOCK KEY (remote) The IT-400 K may be armed and disarmed through the The IT-400 and IT-400 D may be remote armed/disarmed by means of a switch lock Control panel Control disarmed panel electronic key situated on the front panel or with a remote connected to terminals 33 and 34.

This manual is also suitable for:

It-400 kIt-400 d

Table of Contents