Advertisement

Quick Links

3. Usage
3.1 General
Keep fingers behind the finger guards shown below.
Should the straight prod on the passive probe be damaged it can also be
changed. Unscrew the collar and then unscrew the prod from the probe body.
Be careful not to remove the Safety Resistor Cartridge from the probe body.
Screw on the replacement prod and refit the collar to finger tightness. Check
correct operation afterwards.
Please note: The passive probe straight prod and main unit prods are not
interchangeable.
3.2 Voltage Indication
To use as a voltage indicator, touch the prods onto the circuit to be measured.
The voltage between the two points of contact will be indicated immediately. If
the voltage is AC Mains, its impedance will be measured. This is shown by a
pulsing of the display and afterwards either HiZ or LoZ are indicated.
Check the correct function of the VIP
ESI both before and after use with a
true AC output proving unit such as
the Socket and See SP400.
The main body prod is
interchangeable to allow fitting of
either a straight or right-angle prod as
needed. Unscrew the collar, pull the
prod straight out from the main unit,
refit and tighten using normal finger
pressure. Check correct operation
afterwards.
4
Instruction Manual & Specification
Issue1. 01/16
VIP ESI
Electrical Service Industry Voltage
and Impedance Indicator
SnS004v1

Advertisement

loading
Need help?

Need help?

Do you have a question about the VIP ESI and is the answer not in the manual?

Questions and answers

Summary of Contents for SOCKET&SEE VIP ESI

  • Page 1 3. Usage VIP ESI 3.1 General Electrical Service Industry Voltage Keep fingers behind the finger guards shown below. and Impedance Indicator Check the correct function of the VIP ESI both before and after use with a true AC output proving unit such as Instruction Manual &...
  • Page 2 The VIP ESI is designed to be used by skilled persons in accordance with safe methods of work. If the VIP ESI is used in a manner not specified by Socket and See, the protection provided by it may be impaired.
  • Page 3 3.4 Automatic Ghost Voltage Suppression Ghost Voltage suppression is automatic. Firstly they are moderately suppressed by the operating current of the VIP ESI. Secondly the Red and Green Impedance Measurement LED's will show whether the voltage indicated has an impedance of more or less than 100Ω. Should the...
  • Page 4 4. Maintenance and Service Specification If required, clean with a damp cloth and mild detergent. Do not use abrasives Operating Voltage Range 50 - 600V AC or solvents. 50 - 110 - 230 - 400V There are no user-serviceable parts. LED Indication LED illuminates at nominal value -15% Contact Socket and See for service and technical assistance:...