AE
AF
(X25-604X-XX) (B/7)
VR-3100(K,P) ONLY
CN11
1
MUTE
8
2
FAN-ON
7
3
FAN-H/L
10
4
DATA
11
5
CLK
12
6
VST
+5V
+5V
7
+5V
5V
5V
8
-5V
D
9
9
TAPE-2
C507 2.2u50
10
FRONT-V
+
C128 0.022
11
FRONT-C
W194
C127 0.22u50
12
FRONT-Y
+
13
V-GND
CN27
1
GND
2
GND
E
3
GND
4 GND
E18
11
11
CONT-A
10
10
CONT-B
9
CONT-P
8
GND
7
+5V
+5V
6
6
SYNC
F
5
5
V-1
4
V-2
3
V-3
2
V-4
D92
1
WIDE
4
D93
3
D94
2
D95
Q
1
IC11,12,51 : SN761200N
IC13
: TC74HC4051AP
5.0V
IC52
: MC14577CF
R
IC53
: NJU3713D
R912
Q902
4.2V
IC90
: BA7645N
1K
5V
IC91
: NJM4580L
4.9V
AVR
+5V
AG
AH
(X11-380X-XX) (B/7)
J5
R68
220
Rch 1
SECOND ROOM
PRE OUT (ROOM B)
R67
Lch 2
220
J3
R42
(AUDIO)
1K
Rch 1
12
VIDEO 4
PLAY IN
R41
1K
Lch 2
8
R46
1K
Rch 3
4
VIDEO 3
PLAY IN
R45
1K
Lch 4
7
J4
R54
1K
Rch 1
3
VIDEO 2
PLAY IN
R53
1K
Lch 2
6
R58
220
Rch 3
5
VIDEO 1
REC OUT
R57
220
Lch 4
6
R62
1K
Rch 5
2
VIDEO 1
PLAY IN
R61
1K
Lch 6
Q12,14,30,31,52,901
: 2SC4081(R,S)
Q15-17,55
: 2SC4213(B)
Q53
: UN5119 or DTA113ZUA
Q54
: UN5212 or DTC124EUA
Q902
: 2SA1611(M5,M6)
D92-95
: DA204K
D901,902
: MA111
AI
AJ
R71
470K
R69
470K
VIDEO
(AUDIO)
INPUT SEL.
A
B
B
(ROOM A:
A
ROOM B:
)
B
IC4
B
A
A
(BOTTOM VIEW)
R70
470K
C53
100P
16.3V
+17V
ROOM B
IC5
LINE BUFF
(1/2)
C61
4.7u50
3
C65
8
1
10u50
+
2
+
R87 100
R88 100
6
+ C66
7
C62
+
5
10u50
4.7u50
4
IC5
(2/2)
-16.5V
-17V
VR-3100(K,P) ONLY
AK
AL
X25-A/7
-CN25
5/6
IC4 : TC9163AF
IC5 : NJM4565D
D
X25-A/7
-CN26
5/6
E
X08-
CN19
16.3V
3/6
F
X25-A/7
-CN28
CN10
5/6
13
4
STB
16
3
DATA
G
15
2
CLK
1
DGND
-16.5V
CN2
20
NC
19
NC
18
NC
17
PRE OUT Rch
16
PRE OUT Lch
+17V
15
ROOM B BUF Lch
X25-A/7
14
ROOM B BUF Rch
-CN22
13
GND
5/6
C55
150P
12
ROOM A SEL Lch
11
ROOM A SEL Rch
H
10
GND
9
ROOM B SEL Rch
8
ROOM B SEL Lch
7
GND
6
6
VIDEO1 REC Lch
5
5
VIDEO1 REC Rch
4
VIDEO2 REC Rch
3
VIDEO2 REC Lch
17V
2
-17V
+17V
1
+17V
SIGNAL LINE
VR-3090/3100(K,P) (2/6)
GND LINE
KRF-V9992D(M) (2/6)
+B
B LINE
B LINE
B
KRF-V9992D/VR-3090/3100
Y05-3900-10
AM
AN
2SC3944
DTA124EUA
NJM4565D
CAUTION: For continued safety,
replace safety critical components
only with manufacturer's recom-
mended parts (refer to parts list).
indicates safety critical compo-
nents. For continued protection
against risk of fire, replace only with
same type and rating fuse(s). To
reduce the risk of electric shock,
leakage-current or resistance mea-
surements shall be carried out
(exposed parts are acceptably insu-
lated from the supply circuit) before
the appliance is returned to the cus-
tomer.
The DC voltage is an actual reading
measured with a high impedance
type voltmeter with no signal input.
The measurement value may vary
depending on the measuring instru-
ments used or on the product.