Do you have a question about the Sebalog GT-3 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for sebaKMT Sebalog GT-3
Page 1
Consultation with SebaKMT User Manual GSM Transmitter Sebalog GT-3 Mess- und Ortungstechnik Measuring and Locating Technologies Elektrizitätsnetze Power Networks Kommunikationsnetze Communication Networks Rohrleitungsnetze Water Networks Abwassernetze Sewer Systems Leitungsortung Line Locating Issue: 01 (01/2015) - EN Article number: 83923...
SebaKMT All rights reserved. No part of this handbook may be copied by photographic or other means unless SebaKMT have before-hand declared their consent in writing. The content of this handbook is subject to change without notice. SebaKMT cannot be made liable for technical or printing errors or shortcomings of this handbook.
This warranty does not apply to faults in the software supplied. During the period of warranty, SebaKMT agree to repair faulty parts or replace them with new parts or parts as new (with the same usability and life as new parts) according to their choice.
Terms of Warranty Contents Consultation with SebaKMT ................... 3 Terms of Warranty ......................4 Safety Instructions ................... 7 General Safety Instructions and Warnings ............7 General Notes ....................7 Technical Description ..................9 Device construction .................... 9 Function ......................9 Communication ....................
Page 6
Terms of Warranty Determining the GPS position using a smartphone/tablet ....... 36 Working On-Site using the Commander-3 ........... 37 Determining and storing the GPS position ............37 Programming the devices................. 39 Installing devices at the place of use ............... 41 Testing the mobile connection .................
Use genuine accessories to ensure system safety and reliable operation. The use of other parts is not permitted and invalidates the warranty. Repair and Repair and maintenance work has to be carried out by SebaKMT or authorised service maintenance partners using original spare parts only. SebaKMT recommends having the system tested and maintained at a SebaKMT service centre once a year.
Page 8
Safety Instructions Special transportation The lithium batteries of the device are dangerous goods. The transport of the batteries requirements itselves and of devices which contain such batteries is subject to regulations based on the UN Model Regulations “Transport of Dangerous Goods” (ST/SG/AC.10-1). Please inform yourself about the transportation requirements and follow them when shipping the device.
Technical Description Technical Description Device construction External features The GSM transmitter has the following control elements and external features: Element Description Status LED 1 x red, 3 x green when switching on Flashes blue device is switched on and ready for radio communication Permanently blue data transfer taking place...
Sebalog series. LOG RI+ The "LOG RI+" wireless interface is available from SebaKMT as accessory equipment. In comparison with the LOG RI, the wireless module in this device is more powerful, facilitating higher wireless ranges.
2.3.2 Reader-3 as a wireless interface for the computer The "Reader-3" output device from SebaKMT can be used as a wireless interface. Connect the device to the computer via the associated docking station and switch it on. The device will then switch automatically to "USB mode". The device is detected by the computer automatically and is immediately ready to establish a wireless connection.
Technical Description Power supply The GSM transmitter is powered by internal lithium batteries of the brand Energizer Ultimate Lithium AA, but batteries from other manufacturers can also be used. The batteries must satisfy the following technical criteria: Parameters Value Type Lithium battery Size AA (ICE LR6)
Technical Description 2.4.2 Replacing the batteries Empty batteries can be replaced by the user. We recommend that batteries of the same brand and type as those supplied with the device are used. If you prefer to use batteries from a different manufacturer, you should ensure that these batteries fulfill the necessary technical criteria (see page 12).
Technical Description 2.4.3 Resetting the internal logbook This step can be carried out using the Commander-3 or the computer. The GSM transmitter in question must be switched on and ready for wireless communication. Proceed as follows: Step Description Using the Commander-3 Using the computer In the SDV-3 software, select the In Professional mode, open the...
Technical Description Specifications The GSM transmitter has the following technical parameters: Parameters Value Display Status LED Communication Short-distance radio transmission 868 MHz (in Europe) 913/916 MHz (depending on the country) Mobile communication GSM/GPRS modem, 850/900/1800/1900 MHz Power supply 2 x 1.5 V lithium battery Operating temperature -20 ...
Setting Up and Starting the Device Setting Up and Starting the Device Access to SIM card and battery compartment The GSM transmitter must be opened in order to gain access to the SIM card slot or the batteries. NOTE The device contains sensitive semi-conductor components. Take care to avoid damaging the components.
Setting Up and Starting the Device Closing the housing To close the housing, first push the sealing plug carefully back into the housing and then screw the locking ring back on. Please note: The rubber seal of the sealing plug and all contact surfaces must be free from dirt. •...
For this purpose, you can either use your company's own server environment, or you can conclude a user contract with a commercial provider on the Internet. You can also rent storage space on an FTP server from SebaKMT. To do so, please contact your SebaKMT sales partner.
Preparatory Work in the Office Testing the GSM As soon as the SIM card has been inserted, the device should be programmed with the connection necessary GSM connection data so that a GSM connection test can be carried out. Additional information on programming the GSM transmitter and on the GSM connection test can be found in the following sections.
Preparatory Work in the Office Creating a GSM transmitter in the SebaDataView-3 software All GSM transmitters that will be used for the forthcoming measurement must be set up in the SebaDataView-3 software. Proceed as follows: Step Description In the directory tree of the SDV-3 software, select the group to which the GSM transmitter should be added.
Preparatory Work in the Office Programming the GSM transmitter 4.6.1 Entering the GSM settings and transferring to the transmitter The GSM transmitter must be programmed before the measurement is carried out. During this process, all necessary GSM configuration data is assigned to the device. Prerequisites The GSM transmitter must be switched on and within the wireless range of the computer.
Preparatory Work in the Office 4.6.2 Information on the GSM input window The figure shows the input screen for the GSM configuration data. This screen must be completed with all parameters that are required for the correct functioning of the mobile connection from/to the GSM transmitter.
Page 24
Preparatory Work in the Office Segment Parameters If you would like to use SebaKMT's demo server, select the Seba Demo Mode checkbox. The access data is then entered automatically. (Please note that this server may only be used on a short-term...
Preparatory Work in the Office "GSM days" Segment Parameters GSM Transmission Specify the days on which you would like the GSM modem of the GSM transmitter to be active (known as "GSM days"). It will only be possible to upload or send measured data or messages on these days.
Page 26
Preparatory Work in the Office Step Description In the window, click on Check GSM. Result: The GSM test is launched. The GSM transmitter uploads a test file to the FTP server with the name "ftp-test.csv". The GSM transmitter also sends a test email or test SMS to all specified addressees with the following information: ID and comment on the GSM transmitter •...
Preparatory Work in the Office Exporting a logger group from the SebaDataView-3 software and transferring it from the computer to Commander-3 If you are using Log N-3 noise loggers only, then all steps required on-site for installation of the logger and the GSM transmitter can be carried out using the Commander-3.
In order to determine position data using a laptop, you will need an external GPS GPS receiver for laptop receiver from the range of SebaKMT accessories. Simply connect the GPS receiver to the laptop via a USB port. Once connected, the device switches on automatically and starts to search for available satellite signals...
Page 30
Working On-Site using a Laptop The GPS receiver features a status LED: Status LED LED flashes at … Device is searching for GPS signals; • regular intervals still not possible to establish position LED permanently lit … GPS signals are being received; •...
Working On-Site using a Laptop Programming and linking devices Specify which loggers you wish to use on-site and for linking to the GSM transmitter. During this step you can also set the measurement parameters for these loggers. You can set a maximum of three loggers. Proceed as follows: Step Description In the SDV-3 software, select the respective GSM transmitter in the directory tree.
Page 32
Working On-Site using a Laptop Step Description Would you like to select additional loggers for linking to the GSM transmitter? If so, use the second and third drop-down menus and repeat steps 3 and 4 for each additional logger. In the GSM configuration window, click on Program at the bottom right-hand side, and answer "Yes"...
Working On-Site using a Laptop Installing devices at the place of use Install the GSM transmitter together with the linked loggers at the place of use. The devices must be within the same range. Following installation, return the place of use to the exact state in which you found it (close the shaft etc.).
Page 34
Working On-Site using a Laptop Installation examples The following photos show real-life installation examples: Log P 3 pressure logger with GSM transmitter in a German underground hydrant. Log N 3 noise logger with GSM transmitter in a German gate shaft. Log N 3 noise logger with magnetic angled adapter and GSM transmitter with magnetic angled adapter and 90-degree antenna adapter...
Working On-Site using a Laptop Testing the mobile connection Once the logger and GSM transmitter have been installed, checks must be carried out to verify that the mobile connection from the GSM transmitter has been set up without error. Performing the Perform a GSM test directly at the place of installation.
Determining the GPS position using a smartphone/tablet You can determine the GPS position of the place of installation using a smartphone or tablet instead of the laptop. The data is immediately uploaded to the SebaKMT Cloud or to your own server.
In order to determine position data using the Commander-3, you will need the for Commander-3 LOG GPS-3 external GPS receiver from the range of SebaKMT accessories. Simply connect the GPS receiver to Commander-3 via the USB/GPS port. The receiver switches on automatically when connected and the status LED lights up. The device...
Page 38
Working On-Site using the Commander-3 Determining GPS data To determine the GPS position using the Commander-3, proceed as follows: Step Description Connect the GPS receiver to the Commander-3. Move close to the place of installation. Open the menu in the main menu bar of the Commander-3. Result: The menu opens.
Working On-Site using the Commander-3 Programming the devices Specify which loggers you wish to use on-site and for linking to the GSM transmitter. During this step you can also set the measurement parameters for these loggers. You can set a maximum of three loggers. Proceed as follows: Step Description Switch on the respective logger.
Page 40
Working On-Site using the Commander-3 Step Description Change the parameters and click Accept to confirm. Result: The screen switches back to the previous menu level. Would you like to select additional loggers for linking to the GSM transmitter? If so, use the second and third drop-down menus. Repeat steps 8 and 9 to specify the measurement parameters for each logger.
Working On-Site using the Commander-3 Installing devices at the place of use Install the GSM transmitter together with the loggers at the place of use. The devices must be within the same range. Following installation, return the place of use to the exact state in which you found it (close the shaft etc.).
Page 42
Working On-Site using the Commander-3 Installation examples The following photos show real-life installation examples: Log P 3 pressure logger and GSM transmitter in a German underground hydrant. Log N 3 noise logger and GSM transmitter in a German gate shaft. Log N 3 noise logger with magnetic angled adapter and GSM transmitter with magnetic angled adapter and 90-degree antenna adapter...
Working On-Site using the Commander-3 Testing the mobile connection Once the logger and GSM transmitter have been installed, checks must be carried out to verify that the mobile connection from the GSM transmitter has been set up without error. A GSM test must be carried out directly at the place of installation for this purpose. Proceed as follows: Step Description In the Commander-3, open the menu for programming the GSM transmitter (see...
Working On-Site using the Commander-3 Repositioning Poor GSM test results may mean you will need to install the GSM transmitter in a the devices different position to the one originally planned. The determined GPS position may therefore no longer be correct. In this case, you will need to work out the GPS position of the new place of installation.
A message appears on the screen once the procedure has been completed successfully. Click on the Menu button to return to the SebaKMT Cloud main menu. Here, you can determine the GPS positions of additional GSM transmitters if needed. To do so, simply repeat steps 4-6.
Working On-Site using the Commander-3 Transferring logger groups from Commander-3 to the computer and importing them into the SebaDataView-3 software As the final stage of preparatory work in the office, you exported the group data for the logger group in question from the computer to Commander-3. Once on-site work is complete, the data for this group will need to be transferred back from Commander-3 to the computer and imported into the SebaDataView-3 software.
Need help?
Do you have a question about the Sebalog GT-3 and is the answer not in the manual?
Questions and answers