PhysioLogic Premier Combo Plus Instruction Manual

PhysioLogic Premier Combo Plus Instruction Manual

Digital tens/ems

Advertisement

INSTRUCTION MANUAL
INSTRUCTION MANUAL
INSTRUCTION MANUAL
FOR THE
Premier Combo Plus
DIGITAL TENS/EMS
Distributed by:
0434
V1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Premier Combo Plus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PhysioLogic Premier Combo Plus

  • Page 1 INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL FOR THE Premier Combo Plus DIGITAL TENS/EMS Distributed by: 0434 V1.0...
  • Page 2: Table Of Contents

    INDEX Chapter Contents General Description ..........2 Introduction .............2 Cautions ..............4 Warnings ..............6 Contraindications ............6 Adverse Reactions ..........6 Construction ............7 8. Technical Specifications .........9 Replacement Parts ..........15 10. Accessories .............15 11. Graphic Symbols .............16 12. Operating Instructions ..........16 13. Parameter Controls ..........17 14.
  • Page 3: General Description

    HOW TENS WORKS There is nothing “magic” about Transcutaneous Electrical Nerve The Premier Combo Plus TENS/EMS is a fully digital battery oper- Stimulation (TENS). TENS is intended to be used to relieve pain. ated pulse generator that sends electrical impulses to the nerves The TENS unit sends comfortable impulses through the skin that and underlying muscle groups.
  • Page 4: Cautions

    should only be used under medical supervision for adjunctive thera- 9. Turn the TENS off before applying or removing electrodes. py for the treatment of medical diseases and conditions. 10. Isolated cases of skin irritation may occur at the site of electrode placement following long term application.
  • Page 5: Warnings

    Chapter 4 : WARNINGS Chapter 7 : CONSTRUCTION 1. The long-term effects of chronic electrical stimulation are unknown. 2. Stimulation should not be applied over the carotid sinus nerves, particularly in patients with a known sensitivity to the carotid sinus reflex. 3.
  • Page 6: Technical Specifications

    Chapter 8 : TECHNICAL SPECIFICATIONS BACK SIDE The technical specification details of Premier Combo Plus Digital TENS/EMS are as follows: MECHANISM TECHNICAL DESCRIPTION 01 Channel Dual, isolated between channels 02 Pulse Amplitude Adjustable, 0-100 mA peak into 500 ohm load each channel.
  • Page 7 in 0.5 second, then the pulse rate is time. The OFF Time should be equal to or decreased by 50% from its original setting greater than the ON Time. ON TIME ≥Ramp up + Ramp down in 0.5 second. Total cycle time is 1 second. OFF TIME ≥ON TIME In this mode, pulse rate(2-150Hz) and The pre-set parameters of the 24...
  • Page 8 CH1 & CH2 Positive Muscle training SYN 50 CH1 & CH2 Positive Muscle training SYN 50 CH1 & CH2 Positive CH1 & CH2 Positive Muscle training SYN 35 CH1 & CH2 Positive Muscle training CH1 & CH2 Positive Muscle training CH1 &...
  • Page 9: Accessories

    The waveforms of the TENS modes are as follows. 1. Burst The replaceable parts and accessories of Premier Combo Plus DIGITAL TENS/EMS devices are as given below - Except leads, electrodes, battery and battery case cover, please do not try to re- place the other parts of a device.
  • Page 10: Graphic Symbols

    II. LABEL their corresponding terminals in the device. Make sure that the unit is turned off. The label attached to the back of device con- 2) Insert the lead wires into the lead wire sockets on top of the tains important information about this device- device.
  • Page 11 stimulating directly through the area of pain or localized innnerva- higher pulse rates there will simply be increased muscle tension. tion), a higher pulse rate (setting greater than 80Hz on the Pulse Strong muscular contraction is typically not used in TENS therapy. Rate Control) is required.
  • Page 12: Lead Wire Maintenance

    CAUTION NOT reach the desired level if the ramp time is greater than the total contraction time. Do not insert the plug of the patient lead wire into any AC power supply socket. OUTPUT MODE Chapter 15: LEAD WIRE MAINTENANCE The output of both channels are adjustable.
  • Page 13: Tips For Skin Care

    Chapter 18: TIPS FOR SKIN CARE Removal 1. Turn off the unit prior to removing the electrodes. To avoid skin irritation, especially if you have sensitive skin, follow 2. Lift at the edge of electrodes and peel; do not pull on the lead these suggestions: wires because it may damage the electrodes.
  • Page 14: Adjusting The Controls

    Chapter 20 : ADJUSTING THE CONTROLS 3 Mode Control There are 5 TENS modes(B, N, M, S1, S2) and 3 EMS modes 1. Power On/Off/Pause Button (C, S, A) available. The mode is selected by pressing the “Mode” control. When a TENS mode is selected, the LCD shows The power of unit can be turned on by pressing the On/Off/ "TENS".
  • Page 15 c. Set Pulse Width being changed but the output may be stopped by pressing the "On/Off/Pause". Pulse Width is adjustable from 50 µs to 300 µs. Press “SET” control to enter this menu, then press “ ” or “ “ 10.
  • Page 16 f. Adjust Intensity setting, and press “ “ or “ “ to adjust its value. There are 99 steps within the intensity range. Set the desired The settings will be stored immediately after selected. level by pressing the " " or " "...
  • Page 17 e. Set Off Time h. Set Timer The Off Time controls the length of relaxation. By pressing The treatment time is adjustable between 5 - 60 minutes and the "SET" control, the relaxation time can be adjusted. Both Continue(C). Press "SET" control to enter this menu, then channels' stimulation is cycled on and off by the contraction press "Increment"...
  • Page 18: Battery Information

    RECHARGEABLE BATTERIES(NOT INCLUDED) Prior to the use of a new unit, the rechargeable battery should be charged according to the battery manufacturer’s instructions. Be- fore using the battery charger, read all instructions and cautionary markings on the battery and in this instruction manual. Individnal Record Accumulated After being stored for 60 days or more, the batteries may lose their...
  • Page 19: Safety-Technical Controls

    Chapter 24 : MALFUNCTIONS 1. Non-flammable cleaning solution is suitable for cleaning the device. Should any malfunctions occur while using the Premier Combo Plus Note: Do not smoke or work with open lights (for example, Digital TENS/EMS, check candles, etc.) when working with flammable liquids.