Note:
Although the serial connection over USB is easy to setup, there are some disadvantages over the RS232
connection: The output of the bootloader and the boot messages are not shown. The first thing you see is the
login shell. This way it is not usable for system updates.
With the serial connection set up start your favourite terminal program (e.g. minicom) with the following settings:
115200 baud
8 data bits
no parity
1 stop bit
no hardware flow control
no software flow control
If you are using the RS232 connection, you should see debug messages in the terminal from the very first moment
when the target is powered. After the boot process has finished, you will see the Linux login shell:
Garz & Fricke Yocto BSP (based on Poky) @VERSION@ vincell /dev/ttymxc0
vincell login:
You can log in as user
root

3.2 SSH console

Using SSH, you can access the console of the device and copy files to or from the target. Please note that SSH
must be installed on the host system in order to gain access.
To login via SSH, type on the host system:
$ ssh root@192.168.1.1
The first time you access the target system from the host system, the target is added to the list of known hosts.
You have to confirm this step in order to establish the connection.
The authenticity of host '192.168.1.1 (192.168.1.1)' can't be established.
RSA key fingerprint is e5:86:89:19:50:a5:46:52:15:35:e5:0e:d2:d1:f9:62.
Are you sure you want to continue connecting (yes/no)? yes
Warning: Permanently added '192.168.1.1' (RSA) to the list of known hosts.
root@vincell:~#
To return to your host system's console, type:
root@vincell:~# exit
You can use
secure copy (scp)
Example: To copy the file
on the host's console:
$ scp ./myapp root@192.168.1.1:/usr/bin/myapp
To copy the target's
/usr/bin/myapp
$ scp root@192.168.1.1:/usr/bin/myapp ./myapp

3.3 Telnet console

Telnet can be used to access the console. Please note that Telnet must be installed on the host system in order
to gain access.
To login via Telnet, type on the host system:
without any password by default.
on the device or the host system to copy files from or to the device.
myapp
from the host's current working directory to the target's
file back to the host's current working directory, type:
GUF-Yocto-34.0-r5756-0
VINCELL
User Manual
¡
¡
/usr/bin
directory, type
9

Advertisement

Table of Contents
loading

Table of Contents