FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death or property damage.
• Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
• WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use
any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
– If you cannot reach your gas supplier, call the
fire department.
• Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
!
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional
information consult a qualified installer, service
agency or the gas supplier.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
* Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
11
Direct Vent Gas Stove
Installation and Operating Instructions
Models: OXDV30NVSB
WARNING
WARNING
Vermont Castings • Oxford Installation Manual_R4 • 12/16
S
AFETY
5123
Oxford cover
DANGER
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall
be installed for the protection of children and
other at risk individuals.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
CERTIFIED
B
ARRIER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
3-90-20306762
20306543

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OXDV30NVSB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DutchWest OXDV30NVSB

  • Page 1 Direct Vent Gas Stove Installation and Operating Instructions Models: OXDV30NVSB WARNING CERTIFIED AFETY ARRIER FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    Oxford Direct Vent / Natural Vent Gas Heater PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of an Hearth and Home Technologies stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these in- structions may result in a possible fire hazard and will void the warranty. Table of Contents Installation & Operating Instructions Operation General Information .
  • Page 3: General Information

    Oxford Direct Vent / Natural Vent Gas Heater General Information WARNING: Operation of this heater when not connected to a properly installed and maintained venting system The Oxford Direct Vent/Natural Vent Room Heater, Model can result in carbon monoxide (CO) poisoning and No.
  • Page 4: Requirements For The Commonwealth Of Massachusetts

    Oxford Direct Vent / Natural Vent Gas Heater Requirements for the Commonwealth of Exemptions The following equipment is exempt from 248 CMR 5.08(2) Massachusetts (a)1 through 4: All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber. •...
  • Page 5: Oxford Dimensions

    Oxford Direct Vent / Natural Vent Gas Heater Oxford Direct Vent / Natural Vent Dimensions Refer to Page 7 for Flue Collar Centerline Dimensions 6³⁄₄" (172mm) Valve Inlet 24¹⁄₂" (622mm) 28³⁄₈" (721mm) C L Valve 4³⁄₈" Inlet (111mm) 12¹⁄₂" 23" (318mm) (584mm) 17"...
  • Page 6: Unpack Stove

    B. Room Divider E. Flat on wall Propane). C. Island ST207b In Canada, installation must be in accordance with the Dutchwest current CSA B-149.1 Installation Codes and/or local codes. Stove locations Figure 2 - Possible stove locations. 5/15/03 djt The installation should be done by a qualified service...
  • Page 7: Parallel Installation

    ST129c flue centerline. than wood flooring, a metal or wood panel extending the Dutchwest full width and depth of the unit must be used as the hearth. corner specs There are no other hearth requirements.
  • Page 8: Gas Specifications

    Oxford Direct Vent / Natural Vent Gas Heater Horizontal Termination - Direct Vent ONLY Gas Specifications The vent must rise vertically a minimum of 24” (610 mm) off Max. Min. the top of the unit, before the first elbow. The horizontal run Input Input may extend up to 20’ (6 m) and include a vertical rise of up Model Fuel Control...
  • Page 9: Vertical Termination - Direct Vent Only

    Oxford Direct Vent / Natural Vent Gas Heater Vertical Termination - Direct Vent ONLY Vent Termination Clearances A vertical vent system must terminate no less than 8' (2.44 When planning the installation, consider the location of the m) and no more than 40' (12 m) above the appliance flue vent terminal and clearances.
  • Page 10 Oxford Direct Vent / Natural Vent Gas Heater Venting Termination Clearances Venting Requirements and Options - Direct Vent ONLY Approved Vent System Components Your stove is approved to be vented either through the side The heater must be vented to the outdoors through an wall, or vertical through the roof.
  • Page 11: General Venting Information - Termination Location

    Oxford Direct Vent / Natural Vent Gas Heater General Venting Information - Termination Location INSIDE CORNER DETAIL Fixed Closed Fixed Operable Closed CFM145a VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installation US Installations CFM145a Clearance above grade, verenda, porch, deck or 12"...
  • Page 12: Termination Clearances

    Oxford Direct Vent / Natural Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with no side wall...
  • Page 13: Install The Optional Fan

    Figure 14) Retaining Collar 4. The rheostat control switch attaches to the left side of the Rheostat Knob valve bracket at the front of the stove. Figure 15 - Attach the fan rheostat. ST758 Dutchwest attach rheostat 5/15/03 djt 3-90-20306762...
  • Page 14: Venting System Assembly - Direct Vent

    Inner starter pipe and join the two sections 12/4/99 djt ST759 together. Dutchwest • Drill three pilot holes into the Inner Starter and secure restictor plate the assembly with three sheet metal screws. (Figure 5/15/03 3.
  • Page 15: Install Vent Adapter Pipe (Dura-Vent Components)

    Oxford Direct Vent / Natural Vent Gas Heater Install the Vent Adapter Pipe Side Wall Termination Assembly (Simpson Dura-Vent Components) 1. Locate the vent opening on the wall. Refer to Figure 5, to determine the opening centerline. It may be necessary 1. Install the Restrictor Plate: Consult Page 9 to determine to first position the stove and measure to find the hole whether the restrictor plate is needed.
  • Page 16 Oxford Direct Vent / Natural Vent Gas Heater For DuraVent pipe only: Install vent pipe by aligning the locking system together, sliding the pipes together and twisting clockwise. • Install 90° elbow. Twist lock as before. • Slide the wall plate over horizontal run before attaching the horizontal run to the elbow.
  • Page 17: Vent Termination Below Grade

    Oxford Direct Vent / Natural Vent Gas Heater Vent Termination Below Grade Install Snorkel Kit when it is not possible to meet the required Recessed Wall vent termination clearances of 12” (305 mm) above grade level. The snorkel kit will allow installation depth of down Firestop to 7”...
  • Page 18: Venting System Assembly - Natural Vent

    Oxford Direct Vent / Natural Vent Gas Heater 8. Install appropriate pipe sections until the vent run Venting System Assembly - Natural Vent reaches above the flashing. The enlarged ends of the General Information vent sections always face downward. The heater is shipped from the factory as a Direct Vent 9.
  • Page 19: Install The Log Set

    Oxford Direct Vent / Natural Vent Gas Heater Attach the first section of venting to the draft hood. Depending on the length of the individual venting sections Left Log Right Log and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones.
  • Page 20: Burner Information

    Oxford Direct Vent / Natural Vent Gas Heater In the U.S.; Gas connection should be made in accordance To adjust the air shutter, the following procedures should be with current National Fuel Gas Code, ANSI Z223.1/NFPA followed: 54. Since some municipalities have additional local codes, 1.
  • Page 21: Complete The Assembly

    Oxford Direct Vent / Natural Vent Gas Heater The shutter may be adjusted between the factory adjusted Left Burner Leg 1/2” to fully open. Reassemble the shutter to allow the rear injector air inlet to close from the minimum 1/2” opening to fully open.
  • Page 22: Thermostat Connection (Optional)

    Oxford Direct Vent / Natural Vent Gas Heater Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation. Thermostat Wire / Gauge Maximum Run...
  • Page 23: Safety Barrier Installation

    Oxford Direct Vent / Natural Vent Gas Heater DANGER CERTIFIED AFETY ARRIER HOT GLASS WILL CAUSE BURNS. Safety Barrier Installation Instructions DO NOT TOUCH GLASS UNTIL COOLED. NOTE: A barrier designed to reduce the risk of burns from NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 24: Operation

    Follow regular maintenance procedures as described on Page 29. Glow CO105c Figure 48 - Correct pilot and burner flame patterns. Pilot flame 4/10/00 djt Pilot Assembly Figure 46 - Pilot assembly location. ST769 Dutchwest pilot location LG142 5/15/03 djt Stardance Install logs 2 12/11/00 djt 3-90-20306762...
  • Page 25: Lighting And Operating Instructions

    Oxford Direct Vent / Natural Vent Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When •...
  • Page 26: Troubleshooting - Sit Nova 820 Gas Control System

    Oxford Direct Vent / Natural Vent Gas Heater Troubleshooting the Gas Control System SIT NOVA 820 MILLIVOLT VALVE NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. Symptom Possible Cause Corrective Action 1. Spark ignitor will not light A.
  • Page 27: Fuel Conversion Instructions

    Oxford Direct Vent / Natural Vent Gas Heater Fuel Conversion Instructions Remove Screws Rear Log Bracket WARNING! This conversion kit shall be installed by Pilot a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service...
  • Page 28 Oxford Direct Vent / Natural Vent Gas Heater Pilot Orifice Conversion 1. Locate pilot. (Figure 50) 2. Replace pilot orifice. Pilot Pilot Type 1 • Remove pilot hood by lifting up. (Figure 53) Do not remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conversion.
  • Page 29: Maintenance

    Oxford Direct Vent / Natural Vent Gas Heater Table 2. Injector Orifice Size Matrix Conversion to Natural Gas Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum 30005155 #54 / .055" 30000514 #44 / .086" 30000334 19,000 28,000 Conversion to LP (Propane) Input (BTU/h) Kit # Front...
  • Page 30: Glass Replacement

    Oxford Direct Vent / Natural Vent Gas Heater Glass Replacement Inspect the Vent System Annually Replace glass only with Hearth and Home Technologies Have the vent system inspected annually by a qualified approved parts. Refer to Page 32 for Replacement Parts. technician.
  • Page 31: Wiring Diagram

    Oxford Direct Vent / Natural Vent Gas Heater Wiring Diagrams POWER On/Off Switch Wiring CORD Chassis TP/TH Ground Millivolt Gas Valve Black Optional Thermostat Wiring Thermostat Thermostat FAN JUNCTION BOX (Optional) (Optional) Strain Relief St124b TP/TH on/off/switch ON / OFF Rheostat Millivolt wiring...
  • Page 32: Replacement Parts

    Oxford Direct Vent / Natural Vent Gas Heater Replacement Parts 36a,b 15a,b, Hearth and Home Technologies reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Ref. Description Oxford Gas Log Assembly - SDV30 20003458 Rear Log...
  • Page 33 Oxford Direct Vent / Natural Vent Gas Heater Replacement Parts (continued) Ref. Description Oxford Glass, DV25 1601691 Glass Frame Assembly - SDV30 30000127 Gasket, Glass - Med. Knit - RDV40 1203702 Pilot Top Convertible 10002266 Pilot Assembly 3Way N/DV RN 0.199.706 10002264 Pilot Assembly 3Way N/DV RP 0.199.703 10002265...
  • Page 34: Optional Accessories

    Oxford Direct Vent / Natural Vent Gas Heater Optional Accessories Remote Controls The remote control allows you to turn the heater on or off Fan Kits from anywhere in the room. FK26 Fan Model Functions Controlled The FK26 fan helps distribute heated air from within the Push Button, ON/OFF firebox out into the room.
  • Page 35: Warranty

    Oxford Direct Vent / Natural Vent Gas Heater LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Hearth and Home Technologies gas stoves equipped with an Insta-Flame Ceramic Burner. BASIC WARRANTY • Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original Hearth and Home Technologies (hereinafter referred to collectively as warranty, whichever is longest.
  • Page 36: Approved Vent System Components

    Oxford Direct Vent / Natural Vent Gas Heater Approved Vent System Components Flex Venting Components HHT Components* Horizontal Vent Termination Kit includes SLP-HSFTK adj Termination Cap, 1" firestop, 42" F r e e S t a n d i n g S t o v e K i t w / a d j . Flex and adapters Termination Cap, SLP24-BK, SLP6-BK, SLP-FSSK...
  • Page 37 Oxford Direct Vent / Natural Vent Gas Heater 4X6 5/8 SLP Vertical Direct Vent Pipe Flashings SLP-RF6M 0/12 - 6/12 roof flashing (multi-pack of 6) Venting Components SLP-RF12M 7/12-12/12 roof flashing (multi-pack of 6) Through roof flex termination kit includes SLP-TVHW SLP-TVHW, 24"...
  • Page 38: Efficiencies

    Efficiency Ratings EnerGuide Ratings D.O.E Model Fireplace Efficiency (%) (AFUE%) OXDV30NV 63.0 Based on CSA P.4.1-09 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Based on CSA P.4.1-09 Selon CSA P.4.1-09 352 Mountain House Road • Halifax, PA 17032 www.vermontcastings.com...