Rokonet ProSYS ACM Installation Manual

Advanced communication module for use with rokonet’s security systems

Advertisement

Quick Links

C C C C
o o o o
m m m m
m m m m
C C C C
o o o o
m m m m
m m m m
F
o
r
u
s
e
w
F
o
r
u
s
e
w
P P P P
r r r r
o o o o
S S S S
Y Y Y Y
S S S S
P P P P
r r r r
o o o o
S S S S
Y Y Y Y
S S S S
A A A A
d d d d
v v v v
a a a a
A A A A
d d d d
v v v v
a a a a
u u u u
n n n n
i i i i
c c c c
a a a a
u u u u
n n n n
i i i i
c c c c
a a a a
i
t
h
R
o
k
o
n
i
t
h
R
o
k
o
n
- - - -
A A A A
C C C C
M M M M
- - - -
A A A A
C C C C
M M M M
n n n n
c c c c
e e e e
d d d d
n n n n
c c c c
e e e e
d d d d
t t t t
i i i i
o o o o
n n n n
M M M M
t t t t
i i i i
o o o o
n n n n
M M M M
e
t
'
s
S
e
c
u
r
e
t
'
s
S
e
c
u
r
o o o o
d d d d
u u u u
l l l l
e e e e
o o o o
d d d d
u u u u
l l l l
e e e e
i
t
y
S
y
s
t
e
m
i
t
y
S
y
s
t
e
m
s
s

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProSYS ACM and is the answer not in the manual?

Questions and answers

Summary of Contents for Rokonet ProSYS ACM

  • Page 1 P P P P r r r r o o o o S S S S Y Y Y Y S S S S - - - - A A A A C C C C M M M M P P P P r r r r o o o o...
  • Page 2 Advanced Communication Module - Installation Guide...
  • Page 3: Table Of Contents

    Table of Contents Introduction ACM Features Compatibility Mounting & Connections Terminal Block Wiring Jumper Settings LED Indication Programming the ACM - General Adding Deleting the ACM Defining MS Connection Type Defining ACM Parameters Defining the ACM Control Parameters Defining the Network Control Parameters Defining ACM Special Functions Viewing ACM Version and Parameters E-MAIL Report...
  • Page 4: Introduction

    Introduction The ACM (Advanced Communication Module) is a communication accessory for the ProSYS control panel, for enhancing its hardware and software connectivity. It enables TCP/IP Ethernet connectivity and enables usage of existing LAN and WAN infrastructures for the transfer of security data. The ACM offers full functionality of the ProSYS over TCP/IP, and provides Ethernet and Fast Modem Interface.
  • Page 5: Acm Features

    Customizable according to project requirements ♦ Fast modem interface 56-kbps Compatibility The ACM module is compatible with the ProSYS 128, software version 3.10 and above. The ACM is compatible with Rokonet U/D Software Version 1.8 and above. Advanced Communication Module - Installation Guide...
  • Page 6: Mounting & Connections

    Mounting & Connections The ACM may be mounted onto the ProSYS main board using the provided plastic spacers or in a special accessory box (P/N: RP128B300UKA). NOTES Handle the ACM module with care when installing it. 2. When attaching an ACM box to the wall, it is recommended to use Ø4.2mm, 32mm length screws (DIN 7981 4.2X32 ZP).
  • Page 7 Figure 2: ACM Layout with Spacers Advanced Communication Module - Installation Guide...
  • Page 8: Terminal Block Wiring

    Terminal Block Wiring Terminal Description Used to connect the ACM to the ProSYS AUX RED Panel board (the terminals are connected in parallel to the panel BUS connector). COM BLK BUS YEL GRN Provision for optional functionality COM BLK BUS 2 YEL2 GRN2 Used for PSTN telephone line connection (for ACM version that includes the modem...
  • Page 9: Led Indication

    Jumper Description CFG2 Provision for optional functionality LED Indication Description Indicates appropriate communication LINK between the ACM and the Ethernet network. (Yellow) ON: Ethernet communication OK. OFF: Ethernet connection is not working (check cable). Indicates either active or non-active Ethernet ACTIV communication.
  • Page 10 Description Indicates data transmission via the ACM’s MODEM TX optional modem. (Red) ON: Data transmission is in process. OFF: Data transmission is not in process. Indicates either enabled or disabled local STAND ALONE U/D connection to the ProSYS. (Yellow) ON: Local U/D is enabled and ACM U/D channel is disabled.
  • Page 11: Programming The Acm - General

    Programming the ACM - General The ACM Module is programmed in a similar manner to all ProSYS accessories, via the LCD keypad or via the UD Software, locally or remotely. The following information refers to ACM programming features added for ACM functionality.
  • Page 12 Quick Key Parameter [5][1][1][1][1] Defines the CS (Monitoring Station) telephone number connected to the ProSYS panel. Up to 32 digits may be typed in to define the CS telephone numbers, including dialing prefixes and area codes or special letters. For more information refer to the ProSYS Installer manual.
  • Page 13: Defining Acm Parameters

    Defining ACM Parameters From the Dialer menu [5] press [0][2] to enter ACM Parameters Menu. Quick Key Parameter ACM IP ADDRESS [5][0][2][1] The static IP address that identifies the ACM module on the network. Default: 192.168.001.100 ACM U D PORT [5][0][2][2] The port address of the ACM U/D application.
  • Page 14 Quick Key Parameter REMOTE UPGRADE of ACM [5][0][2][8]-[9] Remote upgrading allows remote downloading of upgraded software over the network. The new upgraded software is stored in a specific IP address on the network. Once the ACM is informed of the new software, it refers to the IP address to download the new software.
  • Page 15: Defining The Acm Control Parameters

    Defining the ACM Control Parameters From the Dialer menu [5], press [0][3] to enter the ACM Control parameters Menu. Quick Parameter ACM CONFIGURATION [5][0][3][1] Defines the ACM parameters configuration. CLIENT ATN [5][0][3][1][1] Provision for optional functionality DHCP IP [5][0][3][1][2] Defines whether the IP address, which the ACM refers to, is static or dynamic.
  • Page 16: Defining The Network Control Parameters

    Quick Parameter Provision for optional functionality Defining the Network Control Parameters From the Dialer menu [5], press [0][4] to enter the Network Control parameters Menu. Quick Parameter This option contains parameters that [5][0][4] specify counters for the ACM to establish a connection with the network.
  • Page 17 Quick Parameter ♦ ACM Project Number If a communication trouble with the ACM occurs, the “COMMUNICATION TROUBLE” message appears and 3 beeps are heard from the keypad. Advanced Communication Module - Installation Guide...
  • Page 18: E-Mail Report

    Default: 00110 MAIL PREFIX [5][7][5][6] The ACM email address prefix; 16 characters are used to define the ACM email prefix (for example in the ACM@rokonet.co.il e-mail address, the prefix name is “ACM”). Default: acm Advanced Communication Module - Installation Guide...
  • Page 19: Events Report Over Ip

    [5][7][5][7] MAIL Domain The ACM email address domain name, which identifies the web server of the ACM. For example, in the email address ACM@rokonet.co.il, the domain name is rokonet.co.il. NOTE: Do not enter the @ sign. Default: YourCompany.com [5][7][5][8] MAIL...
  • Page 20 4. Press to confirm; the desired ACM IP address appears on the LCD. Advanced Communication Module - Installation Guide...
  • Page 21: Appendix - A :Ip Address Table

    Appendix – A: IP Address Table Programming User Description Default Location to Programming Configure MS 1 IP Address 192.168.001.010 [5][1][1][1][2][1] MS 2 IP Address 192.168.001.011 [5][1][1][2][2][1] MS 3 IP Address 192.168.001.012 [5][1][1][3][2][1] ACM IP Address 192.168.001.100 [5][0][2][1] SUBNET IP 255.255.255.000 [5][0][2][6] MASK Gateway IP...
  • Page 22: Appendix - C: Common Terms And Definitions

    IP address. The unique name that identifies an Internet site. Domain Names always have 2 or more parts, separated by dots, e.g. www.rokonet.com Ethernet Telecommunications networking protocol; a standard computer interconnection method with a data rate of 100 megabits per second .
  • Page 23 Term Definition SMTP Short for Simple Mail Transfer Protocol, a protocol for sending e-mail messages between servers. SMTP is generally used to send messages from a mail client to a mail server. This is why you need to specify both the POP server and the SMTP server, when you configure your e-mail application.
  • Page 24: Technical Specification

    ACM Basic version RP128AA0100A ACM Basic + Modem Customer Information RTTE COMPLIANCE STATEMENT Hereby, Rokonet Electronics Ltd, declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Advanced Communication Module - Installation Guide...
  • Page 25 Rokonet Limited Warranty Rokonet Electronics, Ltd. and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 12 months from the date of production. Because Seller does not install or connect the product and...
  • Page 26 Contacting Rokonet Rokonet Electronics Ltd. is committed to customer service and product support. You can contact us through our website (www.rokonet.com) or at the following addresses: Tel: +1-305-592-3820 Fax: +1-305-592-3825 e-mail: sales@rokonetusa.com United Kingdom Tel: +44-1527-576-765 Fax: +44-1527-576-816 e-mail: info@rokonet.co.uk...

Table of Contents