Page 1
AVEDUR OWNERS MANUAL Scandia Heating (Aust) Pty Ltd Head Office 306 South Gippsland Highway Dandenong South VIC 3175 Australia Warehouse Lot 1 Melbourne Cresent, Seymore VIC 3660 Australia Model Name Avedur +61 3 5792 2388 Model Number SCGAS10 www.scandiastoves.com.au...
INTRODUCTION Congratulations on purchasing a genuine Scandia gas space heater. When cared for properly, these high quality, finely crafted gas space heaters will offer many years of reliable performance. This instruction manual has been developed to ensure optimum performance from your Scandia gas space heater.
REGULATIONS. WARNING THE SCANDIA AVEDUR HAS A PRIMARY SAFETY GUARD FITTED IN FRONT OF THE GLASS DOOR. THIS SAFETY GUARD IS FITTED TO REDUCE THE RISK OF INJURY FROM BURNS AND AT NO TIME SHOULD THIS GUARD BE PERMANENTLY REMOVED.
COMPLIANCE PLATE COMPLIANCE PLATE SCANDIA AVEDUR GAS LOG FIRE SERIAL NO: MANUFACTURE DATE: IAPMO APPROVAL NO: GMK10437 THIS PRODUCT IS TESTED IN ACCORDANCE WITH AS4553-2008 AND AS3100 NATURAL GAS PROPANE GAS Inlet gas pressure 1.13 kPa 2.75 kPa Outlet gas pressure 0.95 kPa...
YOUR HEATER AT A GLANCE PROPANE CONVERSION AVEDUR OWNERS MANUAL Scandia Heating (Aust) Pty Ltd Head Office 306 South Gippsland Highway Dandenong South VIC 3175 Australia Warehouse Lot 1 Melbourne Cresent, Model Name Avedur Seymore VIC 3660 Australia +61 3 5792 2388...
INSTALLATION GUIDE CLEARANCES TO COMBUSTIBLES It is extremely important that you respect required installation distances and that you respect local installation regulations. This is for your safety! The manufacturer is not responsible for the product, if it is not installed following these recommendations. A combustible surface is anything that can burn (i.e.
Page 8
INSTALLATION GUIDE CLEARANCES TO COMBUSTIBLES ...continued Minimum clearance for a combustible surface Mantel height from top of the Front floor (non-combustible) fireplace opening (mm) 360mm Alcove depth 915mm Side Wall 80mm Isolation switch max distance 1000mm Ceiling 1000mm Mantel Depth (max) 330mm Minimum Framing Dimensions Rough opening (vent pipe)
2 x 900mm flue pipe 1 x 90 Elbow + 4 x 900m flue pipe 2 x 900mm flue pipe Note: Duravent flue products must be used for all installations. IMPORTANT: Your Scandia gas space Heater must be vented directly to the outside.
INSTALLATION GUIDE PROHIBITED AREA FOR FLUE TERMINALS ...continued Reference Item Min Clearance^ Below eaves, balconies and other projections Appliances up to 50 MJ/h input 300mm Appliances over 50 MJ/h input 500mm From the ground, above a balcony or other surface* 300mm From a return wall or external corner* 500mm...
INSTALLATION GUIDE MEDIA INSTALLATION PROCEDURE Vermiculite Burner (Default) Using the vermiculite provided fill the burner up to 10-15mm deep, evenly spread across the tray. Use 3 Lava rocks provided and place them according to the distances below. * 105mm 265mm 120mm Glass Burner Using the glass fill the burner up to 10-15mm deep, evenly spread across the tray.
Page 13
INSTALLATION GUIDE MEDIA INSTALLATION PROCEDURE ...continued Vermiculite Burner with Driftwood (Default) Place the logs and pebbles provided in their designated location. Apart from the burner media, no other log or pebble should cross the flame. Important: Logs and pebbles should be placed in the same location as depicted in the image below. Vermiculite Burner with Pebbles Place the pebbles provided in their designated location.
INSTALLATION GUIDE GAS TYPE CONVERSION The heater is configured for natural gas by default. Use conversion kit included in packaging to do propane gas type conversion. Please follow the steps below to convert the heater to propane gas: STEP 1 STEP 2 STEP 3 STEP 4...
INSTALLATION GUIDE FASCIA INSTALLATION To remove the fascia, carefully lift and pull away from the heater. The Avedur fascia is designed to accommodate multiple wall finishes of varying depth, when installing, align the fascia with the locating lugs in the body of the heater insert slowly until the rear of the fascia is in the preferred position, lower the fascia and the mounting mechanism will self- locate onto lugs.
Ensure that remote control is paired with the heater (Please refer to remote control instructions, page 19) Commission the heater and ensure the operation is satisfactory If you have any problems carrying out any of the tasks above or if the heater operation is not satisfactory, please contact Scandia Heating (Aust) Pty Ltd.
Remote Display Overview The wireless remote control provided with ROOM TEMPERATURE your Scandia gas space heater is the primary controller for all functions (and also operates as the “in room” thermostat when the appliance is being controlled by the remote). App control is...
OPERATING INSTRUCTIONS REMOTE CONTROL INSTRUCTIONS ...continued On/Off Press and release button. If the thermostat is off, pressing and releasing will turn the thermostat on to the most recently selected working mode. Setting The Day Of The Week & Time With the thermostat off, press and hold the button for 2 seconds or longer to initiate programming the time.
Page 19
OPERATING INSTRUCTIONS REMOTE CONTROL INSTRUCTIONS ...continued Programming Each day of the week can be programmed individually for 4 periods P1, P2, P3 and P4, making a total of 28 programmed periods. Alternatively, a weekday program can be set, so the same program is used for Monday-Friday. Similarly, a weekend program can be set for Saturday-Sunday. The entire week can also have the same program.
Page 20
OPERATING INSTRUCTIONS REMOTE CONTROL INSTRUCTIONS ...continued Settings Change between The thermostat temperature display can be set to C or F. The default is P T T MODE With the thermostat off, press the following sequence of buttons: Restore Factory Default Settings P T T With the thermostat off, press the following sequence of buttons:...
OPERATING INSTRUCTIONS APP CONTROL OVERVIEW AND OPERATION STEP 1 STEP 2 STEP 3 STEP 4 Using the device of your choice, Once the download has complete, go Manually select “Avedur_ ” to When you open the app you will see #### download ‘...
ROUTINE MAINTENANCE SCHEDULE We want you to enjoy your Scandia gas space heater for as long as possible. Simple care and maintenance will extend the life of your heater and ensure that you are getting the most out of your purchase. It is recommended that you follow the routine maintenance schedule at least once a year.
HEATER MAINTENANCE COMPONENT ACCESS Before undertaking any maintenance or service activity please ensure the gas space heater is isolated (electrical and gas connections). Access to the Over Temperature Switch STEP 1 STEP 2 The over-temperature switch is Remove the fascia (See instructions centrally located above the door.
Page 24
HEATER MAINTENANCE COMPONENT ACCESS ...continued STEP 3 STEP 4 STEP 5 STEP 6 To remove the reflective panels at the back Ensure that any media has been removed Ensure that any media has been removed Remove two screws and carefully remove of the firebox, remove all 5 screws.
The over temperature safety switch has been activated Allow the heater to cool down and then try to reignite the fire. You may need to reset the heater. If the fire fails to reignite, contact Scandia Heating. Outdoor heavy wind conditions The heater is designed to safely shutdown during heavy wind conditions. If this occurs, please wait until conditions subside.
SPARE PARTS LIST LEGEND PART SCANDIA PART NO. Firebox weldment SPAV001 Air channel SPAV002 Baffle SPAV003 Outer casing SPAV004 Base casing SPAV005 Top casing SPAV006 Top clearance bracket SPAV007 Insulation blanket supporting panel SPAV008 Top heat shield SPAV009 Top block wedment...
Glass fascia SPAV050 Stainless steel fascia SPAV051 Stainless steel - black fascia SPAV052 MEDIA SPARE PARTS LIST LEGEND PART SCANDIA PART NO. White Pebble 1 SPAV100 White Pebble 2 SPAV101 Grey Pebble 1 SPAV102 Grey Pebble 2 SPAV103 Grey Pebble 3...
WARRANTY This limited warranty (Warranty) is given by Scandia Heating (Aust) Pty Ltd (ACN 005 868 093) (Scandia or we) to the original retail purchaser (You) of the gas log fire to which this Warranty applies. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
To obtain replacement or repair under this Warranty, the wood heater must be returned to the original place of purchase (and collected from there once the replacement or repair is complete) at your cost. Scandia will not be responsible for any associated freight, disconnection or re-installation costs (including labour costs).