Wood Burning Inset Stove Installation and Operating Instructions CVSDL04-FP3BLK/CVSDL04-FP4BLK/CVSDL04FP3PWT/CVSDL04-FP4PWT JINDLU04 Rev G 21/04/16...
Page 2
Di Lusso, Emperor Way, Exeter Business Park, Exeter, United Kingdom, EX1 3QS DSEN13229 – Inset Wood Burning Stove Appliance Mass 70kg Efficiency Nominal Heat Output 4.9kW Mean Co Emission (@13% O 0.09% Mean OGC Emission (@13% O 99 mg/m Mean NO...
(where necessary) in accordance with Building OMPETENT ERSONS CHEME Di Lusso recommend that this stove is Regulations. installed by a member of an accredited competent persons scheme e.g. HETAS. Due consideration should be given to air...
Do not attempt to relight the fire until AFETY the cause has been identified and WARNING – This appliance will be hot when corrected. in operation and due care should be taken. If necessary seek professional advice. The supplied operating tool or gloves may be used to open the door and operate the air ADVERSE WEATHER –...
Installation PPLIANCE PENING This stove must be fitted on a hearth or base (N.B. All dimensions are in Millimetres) with adequate load-bearing capacity. The opening into which this stove is fitted PPLIANCE IMENSIONS should be constructed wholly from non- combustible materials. The dimensions of the opening should be at least those shown in the diagram.
400mm and 150mm at the sides. Please check the suitability of any fireplace/surround for closed solid fuel appliances before installation. Di Lusso cannot be held responsible for any fault arising through incorrect use or installation. Fire surround back panels suitable for solid fuel are usually in three sections and slabbed.
EQUIREMENTS The flue serving this appliance must be dry, free from cracks and obstructions and be in accordance with the designations shown in Table 1. The diameter of the flue should not be less than 127mm and not more than 200mm. If these requirements are not met the chimney should be lined by a suitable method.
If you have any doubts about the suitability of your chimney, consult your local RAUGHT dealer/stockist. If the draught exceeds the recommended Both the chimney and flue pipe must be maximum, a draught stabiliser must be fitted accessible for cleaning and if ANY part of the so that the rate of burning can be controlled chimney cannot be reached through the and to prevent over firing.
Page 9
2. Remove the log retainer by lifting it 5. Remove the three rear brick sections clear of the two support pins. noting their positions and orientation. 3. Remove the baffle brick by lifting it up, sliding it to the right and then lowering the left hand edge into the 6.
Page 10
1. Offer the stove into position in the recess pushing it back far enough so that the flanges on the edge of the convection chamber are pushed up tightly against the front of the chimney breast/fireplace. 2. Drill a 6mm hole into the hearth in the centre of the base plate fixing hole.
Page 11
If connecting to an existing masonry chimney it is recommended that a flue forming pipe (short length of flue pipe) is used and the void between the flue forming pipe and the SSEMBLING TOVE chimney filled with vermiculite concrete. 1. Refit the base fixing access plate and A suitable access hole will need to be made in gasket, Air Valve Cassette (with the air the chimney breast to allow the back filling to...
Page 12
OMMISSIONING Upon completion of the installation allow a 4. Release the door catch and hold the suitable period of time for any fire cement door ajar. and mortar to dry out. A small fire may then 5. Offer the Door Fascia into position, be lit and the installation checked to ensure passing the 3x M6 studs through the the smoke and fumes are drawn up the flue...
Operating Instructions To access the air controls press on the door handle to release it from the latch and swing Read the ‘General Guidance’ Section at the it to the right. start of these instructions before operating your stove for the first time. IMPORTANT! - Do not hang pictures, televisions or combustible ornaments above the stove, as these could be damaged and...
Page 14
Combustion Air Control – regulates the flow of air downwards into the combustion chamber via the airwash (airflow over the inside of the glass) and the tertiary air inlet (air inlet holes in the back of the firebox). Turn now be used to regulate the burn rate of the clockwise to open and anti-clockwise to close.
If the rope is in poor condition a replacement rope kit may be Maintenance ordered from the Di Lusso spares range. NNUALLY Important! –In order to ensure continued Annual maintenance of the following should compliance with current Building be carried out by a competent person –...
worn valve remove the air valve cassette, lift ERIODS OF ROLONGED If the stove is to be left unused for a off the worn valve and replace with new. prolonged period, then it should be given a thorough clean to remove ash and unburned fuel residues.
Page 17
Stove Spares PARES JINDLU04 Rev G 21/04/16...
Page 18
Stove Spares PARES JINDLU04 Rev G 21/04/16...