Atop ABLELink Serial-Ethernet ® Server GW21W-MAXI User Manual Version 1.2 Updated on 2004/2/27 Tel: 886-3-5508137 Fax: 886-3-5508131 www.atop.com.tw...
Page 2
The information contained in this document is the property of Atop Technologies, Inc. and is supplied for the sole purpose of the operation and maintenance of products of Atop Technologies, Inc. No part of this publication is to be used for any other purposes, and it is not to be reproduced, copied, disclosed, transmitted, stored in a retrieval system, or translated into any human or computer language, in any form, by any means, in whole or in part, without the prior express written consent of Atop Technologies, Inc.
RS-232/RS-485 serial communication has its limitations. For one, it is hard to transfer data through a long distance. With Atop GW21W-MAXI, it is possible to communicate with a remote device in the Intranet environment or even in the Internet and thus, increases the communication distance dramatically.
User manual Version 1.2 ABLELink Serial-Ethernet Server GW21W-MAXI 2. Nomenclature and Settings 2.1 Nomenclature of GW21W-MAXI Components Figure 2.1 shows the names of GW21W-MAXI components. In the figure, the indicated switch settings represent factory settings. Led Indicator Antenna Mode Switch...
3.2 Assigning a new IP Address by ARP command Arp –s is used to assign a static IP address of GW21W-MAXI and add this static entries to the Arp cache of the computer, when TCP/IP packet with destination port number 1 is sent to GW21W-MAXI, it causes the device to check its MAC address with IP address, once GW21W-MAXI finds those two unmatched, it will reboot and change to the new IP address which was set by Arp –s command.
GW21W-MAXI Note: 1. Arp command can only be used to set a static IP address of GW21W-MAXI using system default user name admin and default password null. 2. Only TCP/IP packet with destination port number 1 will lead GW21W-MAXI to reboot and change the IP address.
GW21W-MAXI. As you can see from the following picture, you can change IP address, gateway IP address, subnet mask, user ID and password of GW21W-MAXI from the utility. For more details of the utility please refer to Appendix-D Configuration Utility.
Page 13
1. If GW21W-MAXI does not receive any command within 1 minute, Telnet will be terminated automatically. 2. The changes of networking parameters will take effect only when you exit and restart GW21W-MAXI. 3. Select “1” from “Input choice and enter (0~5):” to enter overview page as following: This page gives you the general information of GW21W-MAXI including IP and MAC address, SNMP information, kernel and AP version, and connection status of the device.
Page 14
This page allows you to change network settings of the device including IP address, subnet mask, gateway IP address and SNMP information of GW21W-MAXI. Please notice that any setting change made on this page won’t take effect until you restart the device.
Page 15
Type 1 from “Input choice and enter (1~4):” of COM1, the following screen appears. Configure GW21W-MAXI as TCP server and the local port is 4660. IP filter is disabled by default, if IP filter is enabled, only source IP 10.0.0.154 can connect to GW21W-MAXI.
Page 17
TCP/IP Ethernet connection is broken, serial data collected from serial device will be kept in GW21W-MAXI, once TCP/IP connection is resumed, the serial data will be sent through Ethernet connection, you can disable it if you wish.
Page 19
Select “5” from “Input choice and enter (0~5):” the following screen appears. The above page gives you the general information about GW21W-MAXI wireless configurations including the access point it connects to, the current channel and transmitting rate it communicates with the other wireless devices, topology it uses, and what the ESSID (extended service set identifier) and WEP (wireless encryption protocol) are if you use them.
It is also possible to modify various settings through the web server interface. To do so, please follow the steps below. Log in to the system 1. From web browser, type in the IP address of GW21W-MAXI in the URL. Example: http://10.0.50.100 2. The following authentication screen appears. Please type in user name and password then click on “OK”.
Page 29
GW21W-MAXI LINK1 Setup 1. Click on the “COM1” link and the following screen appears, you can configure GW21W-MAXI as transparent mode by default. Configure GW21W-MAXI as TCP server and the local port is 4660, IP filter is disabled by default, if IP filter is enabled, only source IP 10.0.29.11 can connect to GW21W-MAXI.
Page 30
Wireless LAN Setup You can configure wireless LAN parameters through web pages, the following page gives you the information of the access point GW21W-MAXI is connected to, it also allows you to configure GW21W-MAXI’s wireless topology, ESSID and WEP security.
Virtual COM driver mode for windows converts COM data to LAN data to control the RS-232C port on a GW21W-MAXI via the LAN. By creating Virtual COM ports on the PC, Atop Virtual COM redirects the communications from the Virtual COM ports to an IP address and port number on a GW21W-MAXI that connects the serial line device to the network.
4.5.2.1 Enable Virtual COM on GW21W-MAXI From web browser access to GW21W-MAXI by typing its IP address, click on COM1 link to access COM1 page, on the top half of the page click on “TCP Server” and enable Virtual COM by putting a check in front of the “Enable”...
Page 34
GW21W-MAXI 4.5.2.2 Run Serial/IP for ATOP program on monitoring PC In the Window Start Menu, select the Serial/IP for ATOP program group and select Serial/IP for ATOP Configuration. The configuration window is shown as following: At right is a sample Virtual COM Control Panel window.
5. SNMP Setup 5.1 SNMP Network Management Platform Atop GW21W-MAXI is an SNMP device that allows many popular SNMP network management platforms such as HP OpenView and SunNet Manager to conduct monitoring on the device. Depending on the network management tools you are using, device (GW21W-MAXI) information can be collected from running the management tools including IP address, DNS name, system descriptions and NIC information etc.
ABLELink Serial-Ethernet Server GW21W-MAXI 6. Start Writing Your Own Applications Before you start writing your host applications or programs to interact with GW21W-MAXI, please make sure you have done the following. 6.1 Preparing The System 1. Properly connect GW21W-MAXI hardware including power, Ethernet and RS-232/RS-485 cables.
ABLELink Serial-Ethernet Server GW21W-MAXI 7. Diagnostics There are several ways you can check on the status and availability of GW21W-MAXI. 7.1 Use Standard TCP/IP Utility ping Command From Windows Start menu, select Run and type in “ping <TCP Server IP address>”.
Page 45
SG (Signal Ground) SG (Signal Ground) RTS/R- RTS/R- CTS/T- N/A(reserved for Atop devices) Atop provides Mini DIN connector to DB9 connector cable, the pin assignments of DB9 connector is shown in the following table: RS-232 RS-485 RS-485 Pin# Full Duplex...
GW21W-MAXI Appendix B. Upgrade System Software After the new version of firmware is released, customers can download it from Atop’s web site at www.atop.com.tw. You can contact Atop’s sales person to request the newest product CD as well. You may decide to or not to upgrade the system’s firmware. To do so, please follow these instructions listed below.
1. You can always abort the upgrading process by pressing the <Esc> key from host PC during the upgrading process. GW21W-MAXI will restart automatically and the system remains intact. 2. If GW21W-MAXI does not receive any upgrading data within 30 seconds, GW21W-MAXI will restart automatically and the system remains intact.
Appendix C. Hardware Configuration C.1 Disable System Firmware The AP (application program) firmware of GW21W-MAXI can be disabled. This function is used in the situation that you downloaded a wrong version of firmware that caused the system crashed. To disable the current version of firmware and prevent it from executing, please do the followings: 1.
Appendix D Configuration Utility The configuration utility monitor.exe comes with the product CD or diskette is the main utility program to demonstrate and configure GW21W-MAXI’s settings. D.1 Run the utility Start the program under Windows 95/98/NT/2000 environment and the following window appears.
Need help?
Do you have a question about the GW21W-MAXI and is the answer not in the manual?
Questions and answers