8.2 Incidents and solutions

The burner is not working:
Check the boiler thermostat settings.
Carry out the checks mentioned in the burner instructions.
Shutdown by the safety thermostat due to accidental
overheating:
Check that the safety thermostat has not triggered. To restart the
boiler, reset the safety thermostat. Remove the safety thermostat
hood and press the reset button with a screwdriver.
• Standard control panel
• R control panel
Carry out the start-up operations again. Call your fitter.
Check the circuit breaker
• Standard control panel
• R control panel
16/03/2016 - 300019443-02
The burner is operating but the radiators are cold:
Bleed the radiators.
Checking the hydraulic pressure. The hydraulic pressure must
be a minimum of 0.8 bars. Adjust the pressure if necessary,
D000892A
avoiding a sudden influx of cold water into the boiler when it is
hot.
If it is often necessary to top up the installation with water,
contact your fitter.
Check that the heating pumps are working correctly
D000891A
Check the settings on the boiler thermostat(s).
D000889A
D000890A
PK 350 - PK 450 - PK 550
0.8...1.5 bar
See page: 7-8.