4.5.
GROUNDING FOR
ELECTROSTATIC
BREAKDOWN
Prevention
1. Human body grounding
Use the antistatic wrist strap to discharge the static
electricity from your body.
2. Work table grounding
Put a conductive material (sheet) or steel sheet on the
area where the optical pickup is placed and ground the
sheet.
Caution:
The
static
electricity of
groundedthrough the wrist strap. So take care not to let
your clothestouch the optical pickup.
Fig. 5-1
4.6.
METHOD FOR EJECTING THE
DVD TRAY MANUALLY
1. Insert a Screwdriver or similar object into the Eject hole.
2. Press it gently, and then pull the Tray fully out.
Fig. 6-1
your clothes
will not
be
4.7.
SERVICE POSITION
CAUTION:
HOT CIRCUIT (Primary circuit) exists on the Main C.B.A.
Use extreme care to prevent accidental shock when
servicing.
NOTE:
When carring out loading of the cassette tape, if light is
strong, a tape may not carry out loading.
Please shade a Mechanism Unit top or weaken lighting.
4.7.1.
Service Position (1)
13
PV-D4735S / PV-D4745 / PV-D4745S / PV-D4745S-K
Fig. 7-1