Kenwood RXD-M32 Service Manual page 27

Micro hifi component system
Table of Contents

Advertisement

BI
BJ
(X29-269XX-X) (A/6)
C12
1200P
+B
B
-23.0V
R21
0.22 2W
R22
0.22 2W
R26
R25
10K
10K
C16
C15
1000P
1000P
Q4
Q3
4.8V
PROTECTION
(CURRENT
DETECTOR)
+B
+B
D11
R53 47K
R51 47K
R54
3.3K
D12
R52 47K
5.0V
R55
4.7K
Q11
PROTECTION
Q12
0V
B
+B
-23.0V
D2
+B
14.6V
D3
(X29-) (B/6)
FIRST
W276
OFF
D97
R96
4.8V
D96
D95
100
Q92
C82
0.01
WH91
E91
HELP
1
4.5V
R92
POW RELAY
2
3.3K
G
F.OFF
3
+5.1V
4
+5.1V
U GND
5
5.1V
IC91
+5.1V AVR
9.6V
W265
+B
C90
0.047
IC92
3
1
+B
OUT
IN
GND
D99
2
E
BK
BL
CN4
1
HP. DET
WH3
2
Lch
3
Rch
P1
R35
21.7V
+B
100 1W
J1
1 Lch
K1
D8
2 Rch
ON: 0.8V
R36
Q5
3.3K
C
CN3
1 S. W OUT
RELAY
CONT.
2
GND
3
GND
23.2V
C53
0.1
D1
C54
CN1
B
0.1
MAIN
1
1
1
GND
2
2
2
MAIN
3
3
3
+12V
4
4
4
5
+12V
5
5
+7V
6
6
+7V
7
7
FIL
1
8
8
FIL
2
9
9
3
4
5
A
CN93
1
2
3
D93
RELAY
D94
CONT.
S91
Q91
+B
K91
+B
+B
T91
D91
CN91
+B
1
2
(K,P)
: AC120V 60Hz
(M)
: AC110-120V/220-240V~
50/60Hz
(X,H)
: AC240V~ 50Hz
C81
(T,E)
: AC230V~ 50Hz
(J)
: AC100V 50/60Hz
0.01
P91
P92
BM
BN
(X14- ) (F/6)
E100
J100
1
H.P DET
2
H.P L
3
H.P R
HEADPHONE
P100
RXD-SH3MD-L/SH3MD-S/SH3MD-H/SH3MD-LS/SH3MD-W/SH3MD-D/SH3MD-Y (X29-2690-00)
DESTINATION
UNIT
W91,265,
A
E
B
C
W276
No.
290,291
COUNTRY
ABB.
JAPAN
J,J1,J2
0-00
NO
YES
YES
NO
RXD-M32MD-S/M32MD-Y/M32MD-LS/M32MD-L (X29-269X-XX)
DESTINATION
UNIT
W91,
A
E
B
C
W276
No.
265
COUNTRY
ABB.
GENERAL MARKET
M,M1
0-21
YES
NO
NO
YES
AUSTRALIA
X
0-71
NO
U.K.
T
NO
YES
YES
NO
EUROPE
E
2-71
KOREA
H,H1
RXD-M32-S/M32-LS/M32-L/M32-H/M32-Y/M32-W (X29-269X-XX)
H
DESTINATION
UNIT
W91,
A
E
B
C
W276
COUNTRY
ABB.
No.
265
U.S.A.
K
0-11
NO
YES
YES
NO
P
CANADA
M,M1
GENERAL MARKET
0-22
YES
NO
NO
YES
AUSTRALIA
X
0-72
NO
U.K.
T,T1
NO
YES
YES
NO
EUROPE
E,E1
2-72
H
KOREA
RXD-M32E-L/M32E-H/M32E-S/M32E-W/M32E-Y (X29-2692-72)
DESTINATION
UNIT
W91,
W276,
A C
E
B
No.
265
290,291
COUNTRY
ABB.
E2,E3
EUROPE
2-72
NO
YES
YES
NO
CAUTION: For continued safety, replace safety critical com-
ponents only with manufacturer's recommended parts (refer
to parts list).
indicates safety critical components. For
continued protection against risk of fire, replace only with
same type and rating fuse(s). To reduce the risk of electric
shock, leakage-current or resistance measurements shall be
carried out (exposed parts are acceptably insulated from the
supply circuit) before the appliance is returned to the cus-
tomer.
4 5
The DC voltage is an actual reading measured with a high
impedance type voltmeter with no signal input. The mea-
surement value may vary depending on the measuring
instruments used or on the product.
RXD-SH3MD-L/SH3MD-S/SH3MD-D/SH3MD-H/SH3MD-Y/SH3MD-LS/SH3MD-W (5/5)
RXD-M32MD-S/M32MD-Y/M32MD-LS/M32MD-L (5/5)
RXD-M32-S/M32-LS/M32-L/M32-Y/M32-H/M32-W (5/5)
RXD-M32E-L/M32E-Y/M32E-H/M32E-S/M32E-W (5/5)
BO
BP
D11,12,
C13,14,
C17,18,
IC92
P92
D90
R98
R100
C95
F1
F2
95,96
19,20
93
NO
YES
YES
NO
100 1W
NO
NO
0.1
3300u16
1.6A 125V
NO
W290,
C13,
C17-
IC92
P92
D11,12
D90
D95,96
R98
R100
C93
C95
291
14
20
YES
NO
YES
NO
56 1W
0.18
3300u25
NO
NO
NO
560P
0.22
NO
YES
NO
YES
100 1W
0.1
3300u16
W290,
C13,
C17,
C19,
IC92
P92
D11,12
D90
D95,96
R98
R100
C93
291
14
18
20
YES
NO
YES
NO
YES
100 1W
YES
NO
0.1
NO
0.1
YES
NO
YES
NO
56 1W
0.18
NO
NO
560P
0.22
0.22
NO
NO
YES
NO
YES
100 1W
0.1
D11,
C13,
C17-
IC92
P92
D95,96
R98
R100
C93
C95
F1
12,90
14
20
NO
YES
NO
YES
100 1W
NO
560P
0.22
0.1
3300u16
T800mA L 250V NO
Y39-5350-10
BQ
BR
T91
L07-2758-05
F1
F2
T91
T800mA L 250V
L07-2758-05
T800mA L 250V
NO
L07-2897-08
C95
F1
F2
T91
3300u16
1.6A 125V
NO
L07-2758-05
3300u25
T800mA L 250V
T800mA L 250V
3300u16
NO
L07-2897-08
F2
T91
L07-2897-08
RXD-M32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hm-332

Table of Contents