WARNING: This device conforms to the STN EN 55022 standard, class A. It is designed for the connection to a control panel conforming to STN EM 60950 standard. Manipulation with the device in other ways than described in this guide could lead to its damage. Don’t modify the device and don’t try to repair it by yourself.
Basic information GECON Lite plus is a GSM communicator that serves for data transfer through the GSM network via text messages and voice calls. Applications GECON Lite plus is a universal device, it can be used for: property protection – through the connection with the security system it can send alarm messages, inform •...
If the shines only for few seconds (2.5 seconds) the numbers for the input are not set correctly. Gecon Lite Plus Setup GECON LITE PLUS is GSM gateway that allows several modes of operation, therefore it is necessary to setup parameters according to customer needs.
Phone number settings: GECON Plus can send reports to 4 phone numbers. Numbers are set following: T1=090311111 T4=65464464 To delete a number from Gecon, use the command with # character instead of number. Example: Setup of first phone number abcd T1=0901777555 Delete of first number abcd T1=# By inserting a phone number, all events from all inputs are reported to all numbers.
Additional functions These function specify or modify basic functioning of Gecon Lite plus Gateway. Reports routing By default, all events (alarms and troubles) are reported to all numbers in address book. This setting is possible to change, that selected phone numbers (T1-4) will be only reported about events on selected inputs. In this way, you can sort out the reports according to the level of importance.
Example: abcd TEXT - get current texts settings Reply SMS from GECON LITE PLUS will contain object name or event type, and text message after = sign: - object name - texts for alarm/trouble reports from inputs 1 - texts for recovery reports from inputs 1 - text report SMS You can edit the message by typing the type of report, = sign, and text message after the = sign.
- setup of SMS report with 14 days period You will receive SMS message „GECON LITE PLUS: report“ to the T1 number. Practical example: You can send all commands in one configuration SMS if you follow these rules: SMS needs to begin with 4 characters password •...
This function enables monitoring of the control panel with detailed evaluation of all events based on analysis of dictionary of key words. The dictionary defines, on which key words will Gecon lite plus react. If the word is present in the dictionary, standard reaction is sending a SMS message that contains the key word.
Page 11
abcd print=on w1=!ALARM# w2=ARM# w3=DISARM# w4=FAIL# t1=090xxxxxx vt1=5 Example of online report from the security system: 14:25 ALARM PIR-hallway 14:26 DISARM John Smith Example of practical use of this function: 1. Signalization of the alarm event with exact localization 2. Control of arming – disarming Control which particular person armed –...
You can activate control panel mode by sending the command: IBUT=ON GECON LITE PLUS is now set to the control panel mode. Subsequently you will need to programm iButton (Dallas Keys) if they were not already programmed. WARNING !!! Delay of inputs is not functioning in this mode and has to be set to zero level.
Page 13
After receiving above command, buzzer will beep and LED diode will blink with high frequency. In this moment you can add codes of additional keys to memory of Gecon lite plus. You can do it by attaching the keys. Programming (learning of the particular keys) is signalized by double beep of the buzzer.
Page 14
In armed status, red LED diodes on control panes are shining. Entry to the protected space is usually accompanied with activation of alarm detectors connected to Gecon lite plus input loops. This is signalized by short beeps of buzzer and blinks of blue LED diodes. During entry delay (default 20seconds, configurable) Dallas key needs to be attached to the control panel.
Note: The software uses auto detection of port, that means that it will automatically detect Gecon lite plus, there is no need for any special settings. It is recommended to use test tablo to check if all settings are correct. The tablo enable visualization of Gecon lite plus activities without real calls and SMS sending, which could save costs, make settings check faster and more efficient and detects eventual wrong settings.
4. Signaling LED will blink for 10 times and remains shining permanently, 5. Settings are reset, 6. Remove the jumper RES, 7. LED will stop shining, GECON LITE PLUS will register into the network, 8. GECON LITE PLUS is ready to be used. Manufacturer: ZADAKO spol.