Dr. Honle dermalight 80 Operating Instructions Manual

Psoracomb

Advertisement

O
I
PERATING
Before putting the unit into operation and starting the treatment,
read these operating instructions carefully.
#200001 / S 0406 e – 230 V / 50 Hz
NSTRUCTIONS
UV-B-311nm-narrowband
dermalight
psoracomb
Art.-no. #200001 (230V 50Hz)
Art.-no. #200003 (230V 50Hz)
®
80

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the dermalight 80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dr. Honle dermalight 80

  • Page 1 PERATING NSTRUCTIONS ® dermalight psoracomb UV-B-311nm-narrowband Art.-no. #200001 (230V 50Hz) Art.-no. #200003 (230V 50Hz) Before putting the unit into operation and starting the treatment, read these operating instructions carefully. #200001 / S 0406 e – 230 V / 50 Hz...
  • Page 2: Table Of Contents

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS Dear Sir or Madam, ® The dermalight 80 is a handy and economical unit used for the treatment of various skin ® diseases. We hope that you will be satisfied with the dermalight 80 too.
  • Page 3: Safety Information

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS AFETY NFORMATION ® Read the operating instructions carefully before using the dermalight 80 for the first time. All important safety information is marked with this symbol. Please follow these instructions carefully to prevent health risks and damage to property.
  • Page 4 ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS Hazards when using the equipment ® The dermalight 80 was built according to the state of the art and in compliance with recognized safety standards. The equipment must be used only for that purpose for which it was intended, only when in perfect working order.
  • Page 5: Description

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS ESCRIPTION 2.1. ENERAL ® dermalight 80 is a medical UV-irradiation unit designed for mobile use. The emission spectrum of its lamps is in the UVB narrowband-range. The lamps contain a small innoxious part of visible light.
  • Page 6: Operation

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS PERATION ® ® Plug the dermalight 80 into a mains outlet (230 V / 50 Hz). Operate the dermalight only from properly installed socket outlets. The plug should only be operated in horizontal position in order to avoid, that it falls out of the mains outlet (you can use a triple socket ®...
  • Page 7: Electromagnetic Compatibility

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS 3.3. LECTROMAGNETIC OMPATIBILITY  dermalight 80 uses high frequency energy exclusively for its internal function. Therefore its HF-emission is very low and it is unlikely that surrounding electronic devices are disturbed. (HF-emissions acc.
  • Page 8: Fields Of Application And Therapy Information

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS IELDS OF PPLICATION AND HERAPY NFORMATION 4.1. IELDS OF PPLICATION ® With the dermalight 80 it is possible to carry out UVB-therapy, depending on the indications. Indications: Given the latest findings in photodermatology, this means that the following indications can be treated with promise of success: Psoriasis •...
  • Page 9 ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS The duration of the first exposure for hair-covered scalp depends on the extent of the hair covering and its thickness. The purpose of the comb is to part the hair and allow the UV- irradiation to get through to the scalp (see Chapter 4.3.
  • Page 10: Therapy Recommendation

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS 4.3. HERAPY RECOMMENDATION The doctor has to determine the initially treatment time and the increase or decrease of treatment time. Example 1: Psoriasis of the hair-covered scalp Therapy: UV-B-311 nm therapy ®...
  • Page 11 ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS Example 3: Treatment of Vitiligo Distance: 3 cm, use the comb attachment as a distance holder. The comb attachment does not influence the treatment. Frequency: 3 times a week Session Dose Treatment time...
  • Page 12: Maintenance Information

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS AINTENANCE NFORMATION Daily: Check the filter glass for damage and dirt; check the housing for damage. Every 400 operation hours / each 2-3 years in private operation: Replace the lamps. Every 2 years: Maintenance by our Customer Service or a technician authorized by us (applies only to commercial users but is recommended to comply with the Medical Devices Act).
  • Page 13: Spare Parts And Accessories

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS Under no circumstances are you to use: • - Alcohol Perchloroethylene - Baktolan, concentrated Sagrotan, over 2% - Gasoline mix Sidolin - Tincture of iodine, 5% Spirit of wine - Phenic acid Carbon tetrachloride - Lysoform...
  • Page 14: Technical Data

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS ECHNICAL ® Type dermalight 80 psoracomb UV-B-311 nm Order No. / Power supply 200001: 230V/50Hz 200003: 230V/50Hz Power consumption 11 W Lamp 1 x UV-B-311 nm (PL-S 9W/01) Dimensions (L x W x H) 300 x 60 x 45 mm Weight (with power cable)
  • Page 15: Symbols

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS 7.1. YMBOLS Attention, see operating instructions Wear UV-protective googles Part of application type BF Protection class II Alternating current Unit contains electronic parts and may not be disposed in the household rubbish.
  • Page 16: Warranty And Liability

    ® dermalight 80 uva Dr. K. Hönle Medizintechnik GmbH EDIENUNGSANLEITUNG PERATING NSTRUCTIONS ARRANTY AND IABILITY In principle, the General Terms of Sales and Delivery of Dr. K. Hönle Medizintechnik GmbH shall apply. These shall be submitted to the operator upon the signing of contract at the very latest.