The XP15 can operate on any DC voltage from 10-30 Vdc. A bicolor LED on the unit flashes green when input data is detected, but will turn red or yellow if a supply current...
Page 2
“Data In” or leave the OUT– disconnected from those listeners. (See figure next page.) An LED is included on the XP15 to aid in installation and troubleshooting. Whenever input data is detected, the LED will momentarily flash green. A yellow LED usually occurs when too many outputs are connected.
Page 3
XP15 outputs one at a time, while observing that the LED never turns red. If one or more of the listeners causes the red LED to turn on, it is probably because that minus (-) listener input is actually grounded. In this case, you can either use the RS-232 output to drive that listener or leave the minus (-) input to that listener disconnected from the XP15.