1.0 GENERAL ...................................................................................................................................... 2
1.1 Software version .........................................................................................................................................2
1.2 Front panel indications................................................................................................................................2
1.3 Short scroll ..................................................................................................................................................3
1.4 Using the keypad ........................................................................................................................................4
1.5 Automatic and manual modes....................................................................................................................5
1.6 Selecting a profile to run (P1000 Only) ......................................................................................................5
1.7 Starting and stopping a profile (P1000 Only) .............................................................................................5
1.8 Fast on a running profile (P1000 Only) ......................................................................................................5
1.9 HOLD on a running profile (P1000 Only) ...................................................................................................6
2.0 CONTROLLER SCROLL ............................................................................................................... 6
2.1 Modifying data.............................................................................................................................................7
3.0 PROGRAMMER SCROLL (P1000 Only) ....................................................................................... 7
3.1 Profile Program structure ...........................................................................................................................7
3.2 Programmer scroll global parameters........................................................................................................8
3.2.1 Delay Parameter ........................................................................................................................8
3.2.2 Event relay reset status..............................................................................................................8
3.2.3 Parameter PROG ......................................................................................................................8
3.2.4 Parameters Hold and Hold type.................................................................................................9
3.2.5 Repeats ................................................................................................................................... 10
3.3 Profile program parameters .................................................................................................................... 10
3.3.1 Time segment 1 ...................................................................................................................... 10
3.3.2 Level segment 1...................................................................................................................... 10
3.3.3 Segment events ...................................................................................................................... 10
3.3.4 Segment terms sets................................................................................................................ 10
3.3.5 Time segments 2 to 25 ........................................................................................................... 10
3.3.6 Level segments 2 to 25........................................................................................................... 11
4.0 PASSWORD PROTECTION........................................................................................................ 11
4.1 Password entry ........................................................................................................................................ 11
4.2 Manual mode with password protection.................................................................................................. 12
4.3 Selective password protection................................................................................................................. 12
5.0 AUTOTUNE.................................................................................................................................. 12
5.1 General .................................................................................................................................................... 12
5.2 Starting the tuner ..................................................................................................................................... 13
5.3 Stopping the tuner ................................................................................................................................... 14
CONTROLLER LONG SCROLL ELEMENTS ......................................................... 15
CORRUPT PROFILE ERROR CODES................................................................... 16
Contents
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Series1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for FGH Series1000

  • Page 1: Table Of Contents

    Series1000 Operators Manual Contents 1.0 GENERAL ............................2 1.1 Software version ............................2 1.2 Front panel indications..........................2 1.3 Short scroll ..............................3 1.4 Using the keypad ............................4 1.5 Automatic and manual modes........................5 1.6 Selecting a profile to run (P1000 Only) ......................5 1.7 Starting and stopping a profile (P1000 Only) .....................5 1.8 Fast on a running profile (P1000 Only) ......................5...
  • Page 2: General

    Software version When power is first applied to the instrument the main display shows the letters FGH, while the lower display shows the software version number, then 1000 is shown on the lower display. This display is replaced after a few seconds with the usual one described below.
  • Page 3: Short Scroll

    Series1000 Operators Manual useful as a rough guide when the lower display is being used to display something different. Short scroll The 1000 powers up in short scroll. This means that the lower MAN REM TUNE TALK display is displaying one of a short list of parameters;...
  • Page 4: Using The Keypad

    Series 1000 Operators Manual Using the keypad The left and right buttons select a EVNT parameter to be viewed or modified. When one of these buttons is pressed, the next parameter in the scroll list is selected, scrolling forwards or backwards.
  • Page 5: Automatic And Manual Modes

    Series1000 Operators Manual Automatic and manual modes. The auto/man button toggles the controller between automatic and manual modes. Check that output is displayed EVNT on the lower display, (mode indicator 'OP' will be lit), then when the auto/man button is pressed the controller will, if valid, change modes.
  • Page 6: Hold On A Running Profile (P1000 Only)

    Series 1000 Operators Manual HOLD on a running profile (P1000 Only) From within the short scroll the running profile may be held, that is prohibited from proceeding, by pressing and holding the star button and then briefly pressing the left button.
  • Page 7: Modifying Data

    Series1000 Operators Manual Modifying data The up and down buttons are used to change the value of the parameter displayed. There will often be limits to the parameter being modified, and it will only be possible to change the value of the parameter within these limits.
  • Page 8: Programmer Scroll Global Parameters

    Series 1000 Operators Manual Programmer scroll global parameters There is only one of each of the following parameters and they are not related to any particular profile program. 3.2.1 Delay Parameter When the programmer scroll is first entered by pressing and holding the left button, the first parameter to be encountered is DELAY.
  • Page 9: Parameters Hold And Hold Type

    Series1000 Operators Manual 3.2.4 Parameters Hold and Hold type Parameter Hold may be set between 1 and 100 digits. These are in the same units as the measured value. This setting represents the hold band of the profile, ie. if the difference between...
  • Page 10: Repeats

    Series 1000 Operators Manual 3.2.5 Repeats rEPtS is shown on the lower display and a number on the upper display. This number may be set between 0 and 999 by use of the up and down buttons. This number represents the number of times that this profile program will be repeated when it is executed.
  • Page 11: Level Segments 2 To 25

    Series1000 Operators Manual and 100 hours, but in addition, if the down button is pressed when a time of zero is indicated then 'End' is shown on the upper display. This is an instruction to terminate this profile when this segment is run.
  • Page 12: Manual Mode With Password Protection

    Series 1000 Operators Manual Manual mode with password protection To set the instrument to manual mode when auto/man password protection is on, enter controller long scroll, type the correct password and exit long scroll by holding down the right or left button.
  • Page 13: Starting The Tuner

    Series1000 Operators Manual FASt This type results in a Zeigler/Nicholls type response with large overshoots and undershoots. Settling time however will be fast. WARNING During tuning the tuner will, at times, apply 100% power to the plant .This is likely to cause large swings in the process variable.
  • Page 14: Stopping The Tuner

    Series 1000 Operators Manual The tuner is operated by entering the controller long scroll and scrolling to the tunE parameter, in the Contr group. Use the up arrow key to change the current status to be 'on'. This will start the tuning process. While the tuner is working the TUNE status indicator will flash.
  • Page 15: Appendix Acontroller Long Scroll Elements

    Series1000 Operators Manual APPENDIX A CONTROLLER LONG SCROLL ELEMENTS This table shows which parameters will be in the long scroll sequence and which may be, depending on the configuration of the instrument. The relevant column appears under the output type configured.
  • Page 16: Appendix Bcorrupt Profile Error Codes

    Series 1000 Operators Manual APPENDIX B CORRUPT PROFILE ERROR CODES If it is attempted to start a profile program which for some reason has become corrupt then the lower display when in the SEG element of the short scroll, will indicate Err-x where the x will be replaced with a number between 1 and 7 to indicate which of the parameters have become corrupt as follows;...