Navien NCB-150E Installation & Operation Manual
Navien NCB-150E Installation & Operation Manual

Navien NCB-150E Installation & Operation Manual

Ncb-e condensing combi-boilers
Hide thumbs Also See for NCB-150E:

Advertisement

Installation & Operation Manual
NCB-E Condensing Combi-Boilers
Model
NCB-150E
NCB-180E
NCB-210E
NCB-240E
NSF/ANSI 372
H
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result, causing
property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code,
ANSIZ223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Code.
Keep this manual near this boiler for future reference whenever
maintenance or service is required.
* The wetted surface of this product contacted by consumable water contains less than
one quarter of one percent (0.25%) of lead by weight.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NCB-150E and is the answer not in the manual?

Questions and answers

Summary of Contents for Navien NCB-150E

  • Page 1 Installation & Operation Manual NCB-E Condensing Combi-Boilers Model NCB-150E NCB-180E NCB-210E NCB-240E Keep this manual near this boiler for future reference whenever maintenance or service is required. NSF/ANSI 372 * The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight.
  • Page 2 11.4 Component Assembly Diagrams and Parts Lists 11.4.1 Case Assembly Appendixes...
  • Page 3 Description Part # Remark Intake Air Duct Assembly 30008662B Exhaust Pipe Assembly 30008673A Case 20033278A Intake Air Filter 20007668A Air Pressure Sensor 30010346A 30012262A Front Panel 30012269A Cover 30012276B Appendixes...
  • Page 4: Burner Assembly

    11.4.2 Burner Assembly Appendixes...
  • Page 5 Description Part # Remark Damper 30008825A O-Ring (G50) 20003019A Fan Bracket 20022095A Siphon 30012280A 20030283A NCB-150E Burner Chamber Ass'y 30010353A NCB-180E 30008440A NCB-210E/240E Ignition Transformer 30010455A 20027105A NCB-150E Burner Packing 20021677A NCB-180E 20021672A NCB-210E/240E 30014697A NCB-150E 30012322A NCB-180E Heat Exchanger Ass'y...
  • Page 6: Waterway Assembly

    11.4.3 Waterway Assembly 35 16 Description Part # Remark 30015581A NCB-150E DHW Heat Exchanger 30008181A NCB-180E 30005017A NCB-210E/240E Fastener 20007858A O-Ring (P18) 20006954A DHW Outlet Elbow 30012328A Packing 20006852A Appendixes...
  • Page 7 Description Part # Remark Thermistor 30008366A DHW Outlet Adaptor 30003747A DHW Flow Sensor 30012033A O-Ring (P14) 20006952A 30015582A NCB-150E 30010315A NCB-180E DHW Cold Water Adaptor 30010316A NCB-210E 30010317A NCB-240E O-Ring (P20) 20017212A DHW Cold Water Filter 30007878A Vent Pipe 30014737A...
  • Page 8: Fan (Gas) Assembly

    11.4.4 Fan (Gas) Assembly Appendixes...
  • Page 9 NCB-180E 20019141A NCB-210E/240E Venturi Packing 20022660A NCB-180E 20033737A NCB-150E 20024159A NCB-180E (NG) 20019144B NCB-210E/240E (NG) Gas Orifice 20034176A NCB-150E (LP) 20024190A NCB-180E (LP) 20024189A NCB-210E/240E (LP) O-Ring (P34) 20019090A Gas Adapter 30008431A O-Ring (P20) 20006934A 30014321A NCB-150E Gas Pipe 30012338A...
  • Page 10: Outdoor Reset Control (Available With Optional Outdoor Temperature Sensor)

    Outdoor High MIN Low MIN °F °C Absolute High Mass Radiant Low Mass Radiant Navien Outdoor Temperature Sensor Kit Cast Iron Baseboard Custom Radiator Outdoor Temperature Sensor Installation Guidelines Finned Tube Baseboard Avoid areas with temperature fluctuations by direct sunlight,...
  • Page 11 Outdoor Temperature Sensor Installation Guidelines Supply Set-point Return Set-point Heat Load Range Range Finned Tube 120-180°F 101-147°F Baseboard (default) (48.5-82°C) (38-63.5°C) 140-180°F 116-147°F Fan Coil (60-82°C) (46.5-63.5°C) 100-170°F Cast Iron Baseboard 86-139°F (30-59°C) (37.5-76.5°C) 80-140°F 70-116°F Low Mass Radiant (26.5-60°C) (21-46.5°C) 80-120°F High Mass Radiant...
  • Page 12 Memo...
  • Page 13: Getting Service

    Getting Service If your boiler requires service, you have several options for getting service: Contact Technical Support at 1-800-519-8794 or on the website: www.navien.com. For warranty service, always contact Technical Support first. Contact the technician or professional who installed your boiler.

This manual is also suitable for:

Ncb-180eNcb-210eNcb-240e

Table of Contents