Safety Siren Pro Series3 Radon Gas Detector Model Numbers HS71512 USA HS79712 Canada Table of Contents Facts and Concerns Regarding Radon Gas Location of the Detector Areas to Avoid Installation Display Features Short-Term Display Long-Term Display Start-Up Audible Alarm Menu Button Operation Long-Term / Short-Term Test Alarm Mute On / Off...
Facts and Concerns Regarding Radon Gas Radon is a radioactive gas that is colorless, odorless, and tasteless and is impossible to detect without the use of sensitive test equipment. Radon is a naturally occurring gas produced by the breakdown of uranium in soil, rock, and water.
Areas to Avoid • Near drafts caused by heating, ventilating, and air conditioning vents, doors, fans and windows. • Near excessive heat, such as fireplaces and direct sunlight, and areas of high humidity. • Near televisions, computers, radios, all cell phones and cordless phones, or other electrical equipment.
Short-Term Display The display for the short-term reading is an average of the levels of radon gas over the past seven days. The short-term reading allows the user to monitor short-term fluctuations in the home and provide a better feel for problems relating to seasonal and weather related variations in the radon levels.
Audible Alarm HS71512 (USA) 4.0 pCi/L is the level set by the EPA as the threshold at which action should begin to correct the radon problem within the home The detector will alarm in both long-term and short-term modes. HS79712 (Canada) 200 Bq/m is the level set by the Minister of Health as the threshold at which remedial measures should begin.
Alarm Mute On/Off This function allows the user to silence the audible alarm. While in an alarm condition, press and hold the menu button for 15 seconds. As you pass through the test phase as indicated above, the alarm will sound 4 chirps. The display will read “Aoff”.
Do not include the power supply. • Send the unit to Family Safety Products, Inc. 2879 Remico St. SW, Grandville, MI 49418, freight prepaid. The fee for calibration is $75. Calibration time is approximately two weeks. Family Safety Products, Inc.
Error Messages Every 24 hours, the detector will do a self-test. If there is a failure in this self-test an error message will appear in the display window. Err3 Noise Error This error is normally from electrical noise interference. This error can be caused by computers, televisions, fluorescent lights, cell phones, cordless phones or other electrical items.
Specifications Power Source Adapter 120Vac, 60Hz Input for Gas Detector 18VDC, 200mA Sensor Voltage 250VDC Sensor Diffused-Junction Photodiode Full Scale Reading 0.0 to 999.9 pCi/L (0 to 9999 Bq/M Operating Environment 0°C (32°F) to 40°C (104°F) Storage Environment -20°C (-4°F) to 85°C (185°F) Audible Alarm 85dB at 10cm Beeps every hour if long-term...
One Year Limited Warranty Family Safety Products, Inc. warranties this product to the original retail purchaser, to be free from defects in material and workmanship except as otherwise provided herein. This warranty is not transferable and is effective from the date of original retail purchase.
Page 11
This Warranty Does Not Cover: Cost of shipping the product to Family Safety Products. Normal wear, scratches or fading of product. Damage caused by abuse, misuse, tampering with the product including the removal of the back cover. Damage caused by failure to follow installation and use directions found in this manual.
Page 12
Family Safety Products, Inc. 2879 Remico St. SW Grandville, MI 49418 616-530-6540 www.fspi-radon.com 090-MN-RADPRO3A...