Cleaning Your Humidifier; Scale Removal; Before Cleaning - Honeywell hul570 series Instruction Manual

Top fill cool mist humidifier
Table of Contents

Advertisement

Available languages

Available languages

CLEANING YOUR HUMIDIFIER

To keep your humidifier running efficiently, clean it regularly. Weekly cleaning is
recommended. All maintenance should be done in the kitchen or bathroom on a water
resistant surface near a faucet.
To properly clean your humidifier we recommend the separate processes of Scale Removal
and Disinfecting. These two processes must be performed separately.
Step 2
Step 1
Step 4
Step 5

Before Cleaning

1. Turn off and unplug humidifier. Never clean the humidifier when it is running.
2. Remove Water Tank and Tank Cover. Empty water from Tank.
3. Remove accessories, including Demineralization Cartridge, from the Tank if being used.
Do not clean accessories.
4. Remove Mist Outlet, Outlet Cover, Mist Chamber, and Tank Cover.
Note: These four components are dishwasher safe. They may be cleaned in the Top Rack
of the dishwasher or by hand as noted in following instructions. Do not place in the bottom
rack of dishwasher.
5. Holding the Base, empty water from Reservoir by slowly pouring from the top of the Housing
on the opposite side from the Mist Outlet and away from the Power Knob. The Float Paddle
should remain firmly attached to the Brackets in the Reservoir.
8
Step 3
Do not clean
CLEANING YOUR HUMIDIFIER

Scale Removal

Follow steps 1-5 in Before Cleaning section, then follow the additional steps below.
Step 2
Step 1
2C
V
Step 4
Step 5
1.5C
1. Pour a minimum of 2 cups (.5 liters) of undiluted distilled white vinegar in the Water Tank.
Gently swish vinegar around in the Tank to wet entire inside of Tank.
2. Place Tank on Base. Vinegar will drain into the Water Reservoir and loosen mineral buildup
(scale) in the Reservoir and bottom of the Water Tank. There should be enough vinegar to
cover the bottom of the Tank. If not using a dishwasher, the four removable components can
be soaked in the Tank. Just add enough vinegar to cover the components in the Water Tank.
3. Soak for 20 minutes, then remove Water Tank and slowly empty vinegar into sink. Remove
components placed in Tank. Rinse Tank and components with tap water until the smell of
vinegar is gone.
4. Remove Float Paddle from Reservoir by lifting up on Float Rod and set aside.
Wipe Nebulizer and Reservoir area with a soft cloth to remove loosened minerals.
5. Empty vinegar from the Reservoir by slowly pouring from the top of the Housing on the
opposite side from the Mist Outlet and away from Power Knob. Pour 1.5 cups of water into
Reservoir, lightly swish water and pour out. Repeat until smell of vinegar is gone. Avoid
getting water into any openings in the Reservoir area by pouring from the top of the Housing
on the opposite side from the Mist Outlet and away from Power Knob.
CAUTION: Do not submerge the Base in water. Doing so may damage the
humidifier and void the warranty.
6. Place Float Paddle back in Reservoir, ensuring Float Rod is secured in brackets.
For detailed instructions, refer to the Float Paddle Installation section.
CAUTION: Improper placement of the Float Paddle could result in leaking
or water not feeding to the Reservoir.
Wipe outside of housing to dry any water that may have escaped between Base
and Housing.
(CONTINUED)
Step 3
$
MINUTES
Step 6
"Click"
9

Hide quick links:

Advertisement

Table of Contents
loading