® Autotrol Performa Cv ™ Softener/Filter Water Control System Installation, Operation and Maintenance Manual This system installed by: Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Flow Meter 962 Control ........... . . 1-inch Autotrol Turbine Reynolds Water Conditioning Co.
Page 4
Flow Meter 962 Control ........... . 1-inch Autotrol Turbine See Section 4.1 for specification drawings. Reynolds Water Conditioning Co. 24545Hathaway...
15 feet (4.6 m) and water pressure at conditioner is function, the Autotrol Series 1265 bypass offers not less than 40 psi (2.76 bar). You may elevate an Reynolds Water Conditioning Co. simplicity and ease of operation. 24545Hathaway additional 2 feet (61 cm) for each additional Farmington Hills, MI 48335 10 psi (0.69 bar).
Page 6
Overflow line must be a direct, separate line from overflow fitting to drain, sewer or tub. Allow an air gap as per drain line instructions (Figure 1.3). Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Do not run for more than two minutes. b. Advance the cycle indicator COUNTERCLOCKWISE until it points to the Reynolds Water Conditioning Co. 24545Hathaway center of the BRINE/SLOW RINSE position. Farmington Hills, MI 48335 800-572-9575...
Clorox Bleach*. If stronger solutions are used, such b. Proceed with the normal regeneration. as those sold for commercial laundries, adjust the dosage accordingly. *Clorox Bleach is a trademark of the Clorox Company. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Table 4.5 and Table 4.6. The Performa Cv softener valve and the Performa Cv filter valve can be identified by a label attached to the right side of the valve. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Continue changing numbers until you reach the desired setting. Press the SET button. The numbers stop flashing and the control accepts the new Reynolds Water Conditioning Co. setting. After approximately 30 seconds, the control 24545Hathaway starts alternating the display between Time of Day and...
Page 11
Select from Table 2.2 on Salt amount Kilograms page 12. 0.2 to 50.0 1 to 2600 Kilograins Select from Table 2.2 on Capacity of unit Kilograms page 12. 0.1 to 260.0 Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 12
Part Number P7 equals Color 14 in (35.5 cm) 1055737 Brown 16 in (40.6 cm) 1035739 Purple 18 in (45.7 cm) 1035739 Purple 21 in (53.3 cm) 1035884 Dark Grey Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 13
Programming P21 total Brine Draw/Slow Rinse Time. allows the control to start a backwash only when it Reynolds Water Conditioning Co. • This control does not use Parameter P8. No entry is required and not respond to false signals.
Page 14
This selection guide is based on usage since the last regeneration is greater than the media backwash requirements and tank diameter. system capacity minus the reserve, a regeneration is needed. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 15
If more than twice the day’s average is used, the control uses the actual usage in the reserve calculation. Reynolds Water Conditioning Co. Since a new installation has no history of water usage, 24545Hathaway...
Time remote switch must be active to Regeneration 0-254 Seconds start a regeneration switch delay Factory Use Only - DO NOT CHANGE Go to Section 3.2 for detailed explanation of the programming parameters on this page. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 17
Regeneration Switch 0-254 Seconds to start a regeneration Delay Factory Use Only - DO NOT CHANGE Go to Section 3.2 for detailed explanation of the programming parameters on this page. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Time remote switch must be active Regeneration 0-254 Seconds to start a backwash Switch Delay Reynolds Water Conditioning Co. Factory Use Only - 24545Hathaway DO NOT CHANGE Farmington Hills, MI 48335 800-572-9575 Go to Section 2.2 for detailed explanation of the programming parameters on this page.
Page 19
Time remote switch must be active to start a Regeneration Switch 0-254 Seconds backwash Delay Factory Use Only - Reynolds Water Conditioning Co. DO NOT CHANGE 24545Hathaway Farmington Hills, MI 48335 Go to Section 2.2 for detailed explanation of the programming parameters on this page. 800-572-9575...
Page 20
Time remote switch must be active to start a Regeneration Switch 0-254 Seconds backwash Delay Factory Use Only - DO NOT CHANGE Go to Section 2.2 for detailed explanation of the programming parameters on this page. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 21
P/N 1035923 • Triplex Parallel Softener P/N 1035925 • Dual Parallel Filter P/N 1035924 • Triplex Parallel Softener P/N 1035926 Kits include parallel operation cams and the proper interconnect cable. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 22
Day pins should be in the outward position during Clock Dial rotation to prevent an undesired backwash. Reset day pins when completed. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 23
The numbers on the Backwash Dial represent “MINUTES” of backwash time. Backwash Dial Figure 3.2 Backwash Complete Table 3.4 - Cycle Times for 942F Control Cycle Time (Minutes) Backwash 8 - 30 Purge Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
(gallons)(m Smart Reserve: 120% of the daily average (gallons) (m ) calculated from historical values stored in NOVRAM. Reynolds Water Conditioning Co. 24545Hathaway P3 ** Hardness of water If the 962 controller is programmed at P12 to use U.S. units, enter Farmington Hills, MI 48335 hardness in grains per gallon (gpg).
Page 25
Calendar override 0 = No calendar override. 1 - 30 = Maximum number of days between regeneration/backwash. Reserve type See P2. Not used in Alternating mode. Reynolds Water Conditioning Co. 24545Hathaway Immediate or delay Farmington Hills, MI 48335 regeneration 800-572-9575...
Page 26
START-UP, would be 2700 gallon x 1.2 (120% of the daily eliminate any confusion when setting these parameters. average) = 3240 gallon. This daily average will change as actual water usage information is gathered. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
4.2 Injector Curves Injector "L" in a Performa Cv Valve Injector "M" in a Performa Cv Valve Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 29
Injector "N" in a Performa Cv Valve Injector "Q" in a Performa Cv Valve Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 30
Injector "R" in a Performa Cv Valve Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 32
14 (53) 17 (64) 21 (79) *26 (98) 21 (53.3) 19 (72) 24 (91) *29 (98) 24 (60.9) 3.14 25 (95) *May exceed 25 psi or 1.72 bar pressure drop. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 33
* May exceed 25 psi or 1.72 bar pressure drop during backwash of second unit. NR = Not Recommended. A flow control on the service outlet of each valve may be required to insure proper backwash volume to backwashing unit. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335...
This function will not work when the motor is on. The control will beep if the LEFT ARROW ( ← ) button is held for 2.5 seconds and the Reynolds Water Conditioning Co. motor output is on. 24545Hathaway...
To check for proper meter operation, open a Injector Screen downstream faucet and observe the water flow indication, blinking colon, on the control display. Turbine *RoVer is a trademark of Hach Chemical Company Injector Reynolds Water Conditioning Co. Figure 5.1 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
3. Remove the rear cover by depressing the two tabs provided on the cover, Figure 5.3. Lift the front of the cover and remove to expose the valve body. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 Figure 5.5...
Page 37
Position the arrow on the top of the shaft and slide the camshaft into the control. Push up on the end of the camshaft, furthest from the timer, snapping it into place. Figure 5.7 Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
2nd Tank Top 5 - Closed Outlet 4 - Open Purge 6 - Closed 2nd Tank Top 5 - Closed Backwash 7 - Open Purge 6 - Closed Backwash 7 - Closed Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 39
Brine 1 - Open By-Pass 2 - Closed Inlet 3 - Open Outlet 4 - Open 2nd Tank Top 5 - Closed Purge 6 - Closed Backwash 7 - Closed Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Brine 1 - Closed By-Pass 2 - Open Inlet 3 - Open Outlet 4 - Closed 2nd Tank Top 5 - Closed Purge 6 - Open Backwash 7 - Closed Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Bypass flapper held open. b. Valve needs cleaning. Contact the installer. Replace O-ring. Leaking of bypass valve d. O-ring around riser tube d. Replace O-ring. Reynolds Water Conditioning Co. damaged 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
Page 42
Defective circuit board. d. Replace control. 5. Timer does not display correct Outlet operated by a switch. Use outlet not controlled by switch. Reynolds Water Conditioning Co. time of day. 24545Hathaway b. Power outages. b. Reset Time of Day.
Page 43
! flush with clean water. Turbine should spin freely, if not, replace meter. g. Excessive water usage below 1/5 gallon g. Repair leaky plumbing and/or fixtures. per minute. Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...
1053781 Performa Cv 942F, 120V, 60 Hz, 12 Day Control 1000811 Transformer 1000907 Transformer Extension Cord, 15 feet (4.6 m) 1034264 Y-Splitter (run 2 units from 1 transformer) * Not Shown Reynolds Water Conditioning Co. 24545Hathaway Farmington Hills, MI 48335 800-572-9575...