XLT Systems XCU 190 Installation Instructions Manual

X cube lift

Advertisement

X Cube Lift
Model: XCU 190
XCU 180
Installation Instructions
 
0

Advertisement

Table of Contents
loading

Summary of Contents for XLT Systems XCU 190

  • Page 1 X Cube Lift Model: XCU 190 XCU 180 Installation Instructions  ...
  • Page 2: Table Of Contents

    X CUBE LIFT INSTALLATION INSTRUCTIONS Please read installation instructions carefully before installation and keep it for future reference. INDEX: Important Safety Instructions………………………………………….…..….….2 X Cube Lift Overview…………………..…………….…..………….…..…...3 Specifications……………………………………………………………..... 4 Dimensions………………………………………………………………..…5 Installation Instructions 1. Preliminary Checking……………………………………………………..6 2. Guidelines for Installations……………………………………………...… 6 3. Installation on Ceiling…………………………………………………..….7 4.Connecting to Power Supply…………………………………………..……9 5.
  • Page 3: Important Safety Instructions

    Installation and Operation Manual This manual explains how to install, operate and maintain the X Cube lift for video projector. Please read carefully the manual before installation and keep it for future reference. This manual is for installer, interior designer, architect, M&E consultant and system integrator who has known about XLT X Cube lift.
  • Page 4: Cube Lift Overview

    5) Please do not close the lift while the projector is running or while it is in “cool down” operation to avoid premature failure to electrical or electronic components. 6) Please do not step on the lift. Overloading could lead to damage of equipment or injury.
  • Page 5: Specifications

    Specifications: XCU 180 Model XCU 190 660 x 600 (mm) Dimension ( W x D ) 700 x 640 (mm) 330 mm Height in Closed Position 525 mm 28 kg Weight 35 kg 15 kg Max. Lifting Capacity 15 kg...
  • Page 6: Dimensions

    Dimensions A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) XCU 190 XCU 180 5   ...
  • Page 7: Installation Instructions

    4) 100mm (4″) clearances from all surrounding structures are recommended. The minimum ceiling space required for the lift to install at ceiling is 950mmWx850mmDx650mmH for XCU 190 and 900mmWx800mmDx450mmH for XCU 180. The installer must be accessible to every sides of the lift in order to install it.
  • Page 8: Installation On Ceiling

    4) Please refer the table below for mounting holes distances. A (mm) B (mm) C (mm) D (mm0 XCU 190 XCU 180 7   ...
  • Page 9 Adjust the nuts at treaded rods to level the lift. Check that the lift is leveled from front-to-back and side-to-side. A minimum size of opening on false ceiling is required for the lift to travel. XCU 190 XCU 180 Minimum opening ( WXD) 660mm x 660mm...
  • Page 10: Connecting To Power Supply

    4. Connecting to Power Supply CAUTION: Please ensure that the operating voltage of the motor is related to the standard of the local power supply. The motor can be damaged due to incorrect voltage supply. Please do not replace power supply cable of the motor. Please call local dealer should you have any problem with the motor.
  • Page 11: Cable Management

    6. Cable Management 1) Make sure that the cables are long enough for the lift to go up and down. 2) Place all the cables inside the cable carrier. 3) Please check that all the cables are out of the way of operation. 7.
  • Page 12: Adjusting The Positions

    8. Re-adjusting the limit settings NOTE: The UP and DOWN adjustment shall be done within 4 minutes. The motor is equipped with a built-in thermal overload protector which limits their operations to intermittent use only, the power supply will be cut off temporarily if continuous operated for more than 4 minutes.
  • Page 13 10.1. Setting for Lower Position (Service Level) a) Power up the lift after installation, press DOWN button, the lift will travel and stop at the position preset by the factory. b) To delete the limit setting of this position, press the UP and DOWN button simultaneously until the lift begins to move briefly (up and down).
  • Page 14 10.2. Setting for Upper Position (Stored Level) NOTE: Please do not set the UP limit higher than the limit preset by the factory. a) Press the UP button, the lift will travel and stop at the position preset by the factory. b) To delete the limit setting of this position, press the UP and DOWN button simultaneously until the lift begins to move briefly.
  • Page 15 10.3. Setting for Intermediate Position (Projection level) a) Turn on the projector and press UP/STOP or DOWN/STOP buttons to position the lift to the level where the images are aligned perfectly on the screen. b) Press and hold the STOP button until the lift begin to move briefly (up and down), the new position is recorded.
  • Page 16: Optional Accessories

    9. Optional Accessories 1) Dry Contact Transmitter NOTE: The device must be installed by qualified electrician for whom this instruction is intended. Please read the instructions carefully before installation. Please follow the local electrical codes. If you are interfacing the lift with AMX or Crestron, the Inteo Dry Contact Transmitter will be needed.
  • Page 17 Dry Contact Transmitter c) Turn on the power supply to the Dry Contact Transmitter. d) Please confirm the three positions are correctly recorded by pressing UP, DOWN and STOP buttons on hand held transmitter (remote control). e) Press and hold the Programming button at the back of the hand held transmitter ( remote control) until the lift begins to move briefly.
  • Page 18 Programming button f) Press and hold the “PROG” button on the frontside of the Dry Contact Transmitter until the lift begins to move briefly. PROG button g) The three positions are memorized by the Dry Contact Transmitter which automically quits its programming mode. NOTE TO PROGRAMMER: (i) Please program AMX or Crestron contact closure to trigger the lift by ‘pulse’...
  • Page 19 2) Wall Mount Switch PROG UP button button SHOW button DOWN button Wall Switch Back of Wall Switch Should you need to control with wall mount switch, please follow the instructions below to pair wall mount switch and the lift. a) Press and hold the Programming button at the back of the hand held transmitter ( remote control) until the lift begins to move briefly.
  • Page 20 3) XLT Wall Mount switch XLT wall mount switch has to use together with dry contact transmitter where manual override of control system is required. UP button switch SHOW button switch DOWN button switch XLT wall switch ( front ) XLT wall switch ( back ) Please refer the diagram below to connect XLT wall mount switch and dry contact transmitter.
  • Page 21 XLT wall mount switch Dry Contact Transmitter...

This manual is also suitable for:

Xcu 180

Table of Contents