Download Print this page

Probe - Heatcraft Refrigeration Products Masterlog 4 User Handbook Manual

Regulator

Advertisement

d: Defrost parameters
Parameter and description
Display
Type of defrost
0=defrost with elec. element ends with
temperature or time
1=defrost with hot gas ends with temperature or
time
d0
2=defrost with elec. element ends with time
3=defrost with hot gas ends with time
4= defrost with elec. element ends with time or
temperature (if defrost ends with time ED1 and ED2
are not displayed)
dI
Interval between 2 defrosts
dt1
Temperature at end of evaporator defrost
dt2
Temperature at end of aux. evaporator defrost
dP1
Maximum evaporator defrost duration
dP2
Maximum aux. evaporator defrost duration
d3
Delayed defrost activation
Defrost when the controller is switched on
d4
0=no
1=yes
d5
Delay defrost when the controller is switched on
Block display during defrost
0=alternating display of temperature and DEF
d6
1=display temperature present before defrost
2=always display DEF
dd
Dripping duration after defrost
High-temperature alarm (AH) exclusion duration
d8
after defrost and/or door open
d8d
Alarm timer after door opening (alarm "dor")
Priority defrost for delayed compressor
start/stop
d9
0=respected
1=not respected (priority defrost)
d/1
Read defrost probe 1
d/2
Read defrost probe 2
Defrost duration time base
dC
0=hours/minutes
1=Minutes/seconds
Smart defrost: Compressor running time with an
evaporator temperature below D11 to start
d10
defrost
0=function disabled
>0 =running time
d11
Temperature threshold for smart defrost
Auto-adaptive advanced defrost
0=skip defrost disconnected, automatic variation
disconnected
1=skip defrost disconnected, automatic variation
d12
connected
2= skip defrost connected, automatic variation
disconnected
3= skip defrost connected, automatic variation
connected
Average defrost duration in percentage in
dn
relation to dt1 or dt2
dH
Proportional variation factor of dI
Code +050004036 Rel. 1.0 – 11/03/2008
Measurement
Min
Max
unit
Select
0
Time
0
250
°C/°F
-50
200
°C/°F
-50
200
Min
1
250
Min
1
250
Min
0
250
Select
0
Min
0
250
-
0
Min
0
15
Time
0
15
Min
0
250
Select
0
°C/°F
-
°C/°F
-
Select
0
dC
0
250
°C/°F
-20
20
-
0
-
1
100
-
0
100
Bn
Bn
Bn
1
2
3
4
2
0
0
8
8
6
4
4
4
4
4
4
45
45
30
45
45
30
0
0
0
1
0
0
0
120
240
240
2
2
2
2
0
4
4
1
1
1
2
2
2
1
0
0
0
-
-
-
-
-
-
-
-
1
0
0
0
0
0
0
1
1
1
3
0
0
0
65
65
65
50
50
50
Bn
Bn
Bn
4
5
6
2
0
0
12
8
6
4
4
4
4
4
4
45
45
30
45
45
30
0
0
0
0
0
0
120
240
240
2
2
2
0
4
4
1
1
1
2
2
2
0
0
0
-
-
-
-
-
-
0
0
0
0
0
0
1
1
1
0
0
0
65
65
65
50
50
50
10