CLEANING THE GENERATING SET
4.5.1 Clean the generating set using a brush and cloth (water jet cleaning is not recommended). Remove dust and debris around the
exhaust exhaust and the cooling fins.
4.5.2 Clean the engine and alternator air inlets and outlets. Make the most of this cleaning by checking the general condition of the
generating set and change any defective or worn parts.
4.6
CHANGING THE OIL
4.6.1 Warm up the engine on level ground, then switch the engine off.
4.6.2 Remove the oil filler cap.
4.6.3 Place a drain pan under the unit and open the drain plug, letting the oil completely drain out.
4.6.4 Check the gaskets and replace if required.
4.6.5 Refit the drain plug and refill the engine with 0.6ltr of clean engine oil.
4.6.6 Replace the filler cap.
5. STORAGE OF MORE THAN 30 DAYS
Note: If you store the generator for more than 30 days it is essential to protect the fuel system. This can be done by either draining
all the fuel or using a fuel additive such as "STA-BIL¨, "Fuel Fresh¨, or equivalent to prevent fuel gum deposits from forming.
Note: Store the generator in a safe, dry, childproof area, free of excessive humidity and dust.
WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in
the vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling
of fuels.
5.1
CLEAN
5.1.1 Remove debris and dust accumulations from the generating set surfaces.
5.2
DRAINING ALL THE FUEL
5.2.1 Turn the fuel valve ON and siphon the fuel into an approved container.
5.3
USING A FUEL ADDITIVE
5.3.1 Fill the fuel tank with fresh fuel.
Note: If only partially filled, air in the tank will promote fuel deterioration during storage.
5.3.2 Add the fuel stabiliser following the manufacturer's instructions.
5.3.3 Run the engine outdoors for ten minutes to ensure that all untreated fuel has been used.
5.3.4 Stop the engine and move the fuel valve to the OFF position.
5.4
BORE LUBRICATION
5.4.1 Remove the spark plug and pour approximately one tablespoon of clean engine oil into the cylinder.
5.4.2 Crank the engine several times in order to circulate the oil into the cylinder, then refit the spark plug.
5.4.3 Slowly pull the recoil starter cord until some resistance is felt, then keep pulling until the arrow on the starter pulley aligns with the hole
on the recoil starter.
6. TROUBLESHOOTING
PROBLEM
Engine will not start.
Engine runs rough.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycle centre and disposed of in a manner which is compatible with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way.
To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk,
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
CAUSE
Fuel tap not turned on.
No fuel in tank.
Oil not filled to correct level.
Engine run switch not turned on.
Choke not set correctly.
Spark plug fouled.
Air filter blocked.
Air filter blocked.
Spark plug fouled.
Choke set incorrectly.
Dirty/stale fuel.
Environmental Protection
Parts support is available for this product.
email sales@sealey.co.uk or phone 01284 757500.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
ACTION
Turn fuel on.
Fill fuel tank.
Fill oil to correct to level.
Set engine control correctly.
Set choke control correctly.
Clean/replace spark plug.
Clean/replace air filter.
Clean/replace air filter.
Clean/replace spark plug.
Set choke control correctly.
Drain and replace fuel.