  • Page 1 PM300 - 332 - 400 PLANTER MONITOR...
  • Page 2: Table Of Contents

    Highlighted Digit for Editing......................18 Installation ......................19 Standard Mounting Bracket ..................... 19 Optional Mounting 3D Adjustable Bracket ............... 20 Installing Console Harnesses ..................21 Installing Implement Harness and Sensors ..............22 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 3 Shaft Speed Low/Hi Limit Warning.................. 44 Flow Low/Hi Limit Warning ....................44 Failed Ground Speed Sensor ..................45 Battery Hi/Low ......................... 45 Self-Test Failure ......................46 Hi Ground Speed Exceeded (Optional) ................46 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 4 Accessory Alarm Sounds When Shaft, Fan or Flow is Working ........49 Ground Speed Alarm Sounds When Forward Movement ..........49 Ground Speed High Alarm Sounds ..................49 Self-Test Alarm .........................50 Connector Pin-Outs ......................51 Connector Pin-Outs ......................52 Warranty ......................57 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 5 TABLE OF CONTENTS PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 6: Safety Notices

    Use of the word CAUTION without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in equipment damage. SAFETY NOTICES / 1 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 7 OPERATOR’S MANUAL 2 / SAFETY NOTICES PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 8: Introduction

    Figure 1 provides an illustration of a generic console. The PM300, PM332, and PM400 are designed to meet the custom needs of individual users. The display may be configured to output a comprehensive set of planter parameters.
  • Page 9 Rows 2, 4, 6, 8 (above limit) alarm Row scan and average spacing with screen blinking symbols and row 1 hi alarm (alarm cancel returns user to operate screen) 4 / INTRODUCTION PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 10: Specifications

    18.4 cm W x 20.1 cm H x 4.3 cm D (7.3" W x 7.9" H x 1.7" D) Weight 4.4 lbs for 16-row PM300 system 4.8 lbs for 32-row PM332 system 6.4 lbs for 36-row PM400 system *Weight includes console and attached cables (battery power cable and signal cable that extends to the drawbar).
  • Page 11 OPERATOR’S MANUAL 6 / INTRODUCTION PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 12: Major Features

    OPERATOR’S MANUAL MAJOR FEATURES PERFORMANCE • Planter monitoring of 16 row (PM300), 32 rows (PM332), or 36 rows PM400 • Monitoring of ground speed, two hopper levels, one frequency function (fan, shaft, or flow) • Easy and flexible configuration •...
  • Page 13 OPERATOR’S MANUAL 8 / MAJOR FEATURES PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 14: Quick Start Guide

    Configuration Row Spacing 75,0 Row Setup The PM300, PM332, and PM400 can store three planter configurations for users with split row planters or multiple planters and seeders, but many users store only one configuration. ENTER To select a planter configuration number (1, 2, or 3) 1.
  • Page 15: Row Spacing

    6. When the field shows the correct planter row spacing, press Enter to confirm the selection. 7. Once the new values are entered, select either the Escape or Operate key to return to the Operate (main) screen. 10 / QUICK START GUIDE PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 16: Ground Speed Configuration

    6096 400 ft Ground Speed Start symbol (will Source change to (Radar or Stop symbol when Reluctance) test begins Manual ground speed (optional) Maximum speed alarm (optional) QUICK START GUIDE / 11 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 17: Help Card

    ESCAPE Escape key HELP CARD The help card (Figure 7) may be cut out to provide a compact reference for definitions, set-up screens, and general operating information. 12 / QUICK START GUIDE PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 18 No flow All Rows Failed Planter Lifted No Speed Input Stop Configuration Start Reset Security Password Save Password English/Metric Back light Graphic/Text Label Alarm Population Adjust Response Rate QUICK START GUIDE / 13 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 19 OPERATOR’S MANUAL 14 / QUICK START GUIDE PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 20: Key Functions

    If the error condition continues, the key must be selected again to cancel the alarm. When no alarms are active, the volume may be modified by selecting and holding the Alarm Cancel key. Alarm Cancel key KEY FUNCTIONS / 15 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 21: Enter Key

    (population — default, blockage, skipped, or disabled). SETUP If data on another screen is changed, it is saved when this key is selected. Planter Setup key 16 / KEY FUNCTIONS PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 22: Ground Speed Setup Key

    (FIELD AREA 1, FIELD AREA 2, and Speed Area Mode key TOTAL AREA). If data on another screen is changed, it is saved when this key is selected. KEY FUNCTIONS / 17 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 23: Editing Screen Fields Using Keys

    Arrow keys on the Control Panel. Press Enter to accept ESCAPE and confirm the selection. ENTER 6096 400ft 00.0 G N D S P D C O N S TA N T 18 / KEY FUNCTIONS PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 24: Installation

    Save all packing materials until the inspection is complete. If damage is found, immediately file a claim with the carrier and notify your DICKEY-john Sales Representative. STANDARD MOUNTING BRACKET Install the mounting bracket at the desired location using locally acquired...
  • Page 25: Optional Mounting 3D Adjustable Bracket

    The console must not obstruct the view of the operator or interfere with the operation of the tractor. To prevent damage to the console, be sure the snap fully engages during installation. 20 / INSTALLATION PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 26: Installing Console Harnesses

    OPERATOR’S MANUAL INSTALLING CONSOLE HARNESSES Several harnesses are located at the bottom of the PM300, PM332, and PM400. These include power, ground speed sensor, and sensor inputs (rows, lift switch, two hopper levels, and one frequency function [shaft/fan/ flow]). Figure 11...
  • Page 27: Installing Implement Harness And Sensors

    The harnesses must not obstruct moving parts of the tractor or implement. Take care when routing harnesses to retain them at proper locations with adequate slack for movement. 22 / INSTALLATION PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 28: Advanced Setup

    This is used for split row systems where every other row or sets of internal rows are not planting. Their corresponding row number is ignored, allowing for true planting operations to be displayed on the monitor. ADVANCED SETUP / 23 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 29: Ground Speed Setup

    The manual ground speed (optional) may be used when a ground Ground Speed Setup key speed sensor is not installed or has failed in the field. The maximum speed alarm (optional) provides the user with an over-speed alarm. 24 / ADVANCED SETUP PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 30: Manual Ground Speed Constant Entry

    To verify that the correct calibration number has been obtained, move to the Enter key Speed Area Mode screen. 1. Press the Speed Area Mode key. ADVANCED SETUP / 25 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 31: Accessory Setup (Optional)

    A fan, shaft, or flow sensor may be monitored with HI and/or LOW alarms or no alarm values. Refer to Figure 16. 26 / ADVANCED SETUP PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 32 Stop the monitor calibration by selecting the Enter key again. Highlight the revolutions or liquid level window. Select the Enter key. Enter the number of revolutions (shaft/fan) or gallons (flow). Stop symbol ADVANCED SETUP / 27 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 33: Limits Setup (Population) (Optional)

    6. Select either the Escape or Operate key to return to the Operate (main) screen. ENTER If no value is entered, the monitor uses average population to calculate alarms or row population indicators. Enter key 28 / ADVANCED SETUP PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 34: Hi Population/Low Population

    1. Move the slide to the right when planting high seed rates and to the left when planting low seed rates. (refer to Figure 17). 2. Press the Operate key to return to the Operate (main) screen. ADVANCED SETUP / 29 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 35: Units Of Measurement, Backlighting And Alarm Volume Control

    To display the service screen: Up or Down Arrow keys 1. Press the Display & Service key. 2. Highlight the Service icon and press Enter. ENTER Enter key 30 / ADVANCED SETUP PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 36: Security Screen

    10. Highlight the padlock and select the Enter key to toggle the unlocked state to locked. The selected screens will require input of the password Escape key prior to modification. ADVANCED SETUP / 31 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 37 Figure 20 Security Screen and Screens That May Be Locked 0000 III.I 0000 Configuration softkey III.I 1 2 3 1,2,3 . . . Configuration Screens that may be locked 32 / ADVANCED SETUP PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 38: Auxiliary Modes

    The SEED COUNT mode is used to determine row unit performance when SEED COUNT operating in a stationary manner. A reset for all rows is included (refer to MODE Figure 22). AUXILIARY MODES / 33 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 39 OPERATOR’S MANUAL Figure 22 Seed Counting Mode Reset option 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 9,521 34 / AUXILIARY MODES PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 40: Monitoring Planting

    An example of five parameters selected: 1 = Average population 2 = Speed 3 = Field area 4 = Total area 5 = Shaft RPM MONITORING PLANTING / 35 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 41 10 11 12 13 14 15 16 17 18 10 11 12 13 14 15 16 17 18 2 Parameter Functions 3 Parameter Functions 4 Parameter Functions Up or Down Arrow key 36 / MONITORING PLANTING PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 42: Customizing The Lower Parameter Window

    3. Highlight the Row Indicator Type or Row Indicator Size icon to change. 4. Press the Up or Down Arrow key to cycle through desired setting. 5. Press Enter to accept selection. Up and Down Arrow keys MONITORING PLANTING / 37 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 43: Available Planting Parameters

    This function may be labeled with a symbol or text, depending on the text/ Average Population graphic setting. 38 / MONITORING PLANTING PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 44: Minimum/Average/Maximum Population

    The displayed row is incremented every two seconds. After the last row is displayed, the scan will resequence beginning with the first active row. Seeds Per Distance Row Scan MONITORING PLANTING / 39 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 45: Field Area 1

    Shaft function displays the shaft's speed in revolutions per minute (RPM). FLOW Flow displays the flow rate speed in gallons per acre (g/ac) or liters per hectare (l/ha) depending on the English/Metric setting. Shaft Flow 40 / MONITORING PLANTING PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 46: Alarms

    2. Power on/off sequence occurs before problem is corrected. 3. An All Rows Failure alarm occurs then the console again detects less than 2 seeds per second through the seed tube. ALARMS / 41 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 47: All Rows Failure

    1. Tractor is stopped while planter is in the ground. 2. Tractor is operating with planter lifted. 3. Normal “end of run” turn around. Figure 30 All Rows Failure Display 42 / ALARMS PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 48: Hi/Low Population Warning

    Setup mode (Refer to Figure 32). Alarm can be silenced by pressing Alarm Cancel key, but will re-activate if problem is not resolved. Figure 32 Fan Speed Limit Warning Display (Optional) LOW FAN SPEED HIGH FAN SPEED ALARMS / 43 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 49: Shaft Speed Low/Hi Limit Warning

    Alarm Cancel key, but will re-activate if problem is not resolved. Figure 34 Flow Low/ Hi Limit Warning Display (Optional) HIGH FLOW RATE LOW FLOW RATE 44 / ALARMS PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 50: Failed Ground Speed Sensor

    VDC. Alarm indicates an electrical problem exists that must be corrected. The alarm cannot be shut off and will continue to sound until corrective action is taken. Figure 36 Battery Failure Display HI BATTERY VOLTAGE 1 6 . 5 ALARMS / 45 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 51: Self-Test Failure

    Ground Speed Setup screen. Alarm can be silenced by pressing the Alarm Cancel key. Figure 38 Maximum Speed Exceeded Warning Display (Optional) HI GROUND SPEED 46 / ALARMS PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 52: Troubleshooting

    2. Be sure connections are clean and tight. Inspect harness for damage. 3. Console voltage must be at least 10 V. If low, recharge or replace battery. 4. Console is damaged. Contact your dealer, DICKEY-john USA (1-800-637-3302) or DICKEY-john Europe (011-33-141-192189). ROW FAILURE OR HI/LOW ALARM WHEN ROW IS...
  • Page 53: Hopper Alarm Does Not Sound When Hopper Is Empty

    2. Swap harness connection with another sensor to determine if sensor or harness is damaged. Use service screen if another sensor is not available. Replace sensor or repair harness. 3. Console is damaged. Contact your dealer, DICKEY-john USA (1-800-637-3302) or DICKEY-john Europe (011-33-141-192189). HOPPER ALARM SOUNDS WHEN HOPPER IS...
  • Page 54: Accessory Alarm Sounds When Shaft, Fan Or Flow Is Working

    2. Sensor calibration number is incorrect. Check calibration number in accessory setup screen. 3. Sensor limits are incorrect. Check limits in accessory setup screen. 4. Console is damaged. Contact your dealer, DICKEY-john USA (1-800-637-3302) or DICKEY-john Europe (011-33-141-192189). GROUND SPEED ALARM SOUNDS WITH...
  • Page 55: Self-Test Alarm

    LED, swap harness connection with adjacent sensor to determine if sensor or harness is damaged. Replace sensor or harness. 2. Console is damaged. Contact your dealer, DICKEY-john USA (1-800-637-3302) or DICKEY-john Europe (011-33-141-192189). 50 / TROUBLESHOOTING PM300, PM332, PM400 Planter Monitors...
  • Page 56: Connector Pin-Outs

    RS-232 Rx (blue/red) Row 31 (red/black/green) RS-232 Tx (red/green) Row 32 (green/black/orange) Lift switch (orange/red) Lift Switch (white) Ground Speed Pin # Description Ground (black) Signal (green) Power (red) Sense (white) TROUBLESHOOTING / 51 PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 57: Connector Pin-Outs

    No connection Row 22 (blue/red) No connection Row 23 (red/green) No connection No connection +8 V Snsr Pwr Left (red) No connection +8 V Snsr Pwr Right (red) No connection 52 / TROUBLESHOOTING PM300, PM332, PM400 Planter Monitors 11001-1372-201702 Rev B...
  • Page 58: Warranty

    Europe: DICKEY-john Europe S.A.S, 165, boulevard de Valmy, 92706 – Colombes – France TEL: 33 (0) 1 41 19 21 80, FAX: 33 (0) 1 47 86 00 07 WEB: www.dickey-john.com © 2017 DICKEY-john Specifications subject to change without notice.
  • Page 59 DICKEY-john Technical Support 800-637-3302 service@dickey-john.com Europe Sales and Technical Support +33 1 41 19 21 80 europe@dickey-john.com DICKEY-john, the DICKEY-john Logo and IntelliAg are 5200 Dickey-john Road 217-438-3371 registered trademarks of DICKEY-john. Auburn, IL 62615 217-438-6012 fax www.dickey-john.com ©2017 DICKEY-john...