SECTION 1 - INTRODUCTION

General

The Barton
Model 202E single DP Flow Recorders measure and record system
®
Operation parameters including gas and liquid flow rate, liquid level in a vessel,
and other system variables that can be measured by differential pressure and
static pressure methods.

Main Components

Differential Pressure Unit
The Barton
Model 199 Differential Pressure Unit (DPU) actuates the recorders.
®
The DPU is a dual bellows assembly enclosed within pressure housings. The
bellows are liquid filled and withstand overranges equal to the working pressure
of the housing without calibration change. Movement of the bellows is transmit-
ted through a torque tube from the DPU to the recording mechanism. The
torque tube is hermetically sealed to eliminate friction and leakage; it does not
require lubrication.
Before installing this instrument, become familiar with the installation instructions
in Section 2. WARNING notes that appear on the following pages of this manual
should be reviewed before proceeding: 8, 20, 21, 22, and 25.
WARNING notes indicate the presence of a hazard which can cause severe personal injury, death, or substantial
property damage if warning is ignored.
CAUTION notes indicate the presence of a hazard which can cause moderate personal injury or property
damage if warning is ignored.
DIFFERENTIAL PRESSURE RECORDERS
Bar ton
Bar
Bar
ton
ton
ton
Bar
Bar
ton
Manual No. 10060, Rev. B
SAFETY !
® ® ® ® ®
MODEL 202E
User Manual
05/2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Barton 202E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NuFlo Barton 202E

  • Page 1 Bar ton ® ® ® ® ® MODEL 202E DIFFERENTIAL PRESSURE RECORDERS User Manual Manual No. 10060, Rev. B 05/2004 CONTENTS Section 1 - Introduction ..............Page 1 Pressure Elements/Chart Drive Tables ........Page 5/6 Section 2 - Installation/Calibration Check ........Page 7 Section 3 - Maintenance &...
  • Page 14 Apply 50% differential pressure to the high-pressure side. Arrange the differential pressure linkage as shown on page 12. Set a 90° angle between the drive arm and link. By varying the length of the link, set a 90° angle between the range arm and link.
  • Page 20 If the housing does not move freely – the bellows may be pressurized and is potentially hazardous if further disassembled. Tighten the bolts and return the unit to the factory or authorized NuFlo service center for repair. Tag the unit and specify “Gas in Bellows”. B. Cleaning/Inspection Procedure Instruments used where solids or semi-solids may accumulate inside the pressure housings require periodic inspection and cleaning, as follows.
  • Page 40 NuFlo Technologies, Inc. warrants that at the time of shipment the products manufactured by NuFlo Technologies, Inc. and sold hereunder will be free from defects in material and workman- ship, and will conform to the specifications furnished by or approved by NuFlo Technologies, Inc.