AGENCY PLACEMENT RECOMMENDATIONS
NFPA 72 Chapter 29
"For your information, the National Fire Alarm and Signaling Code, NFPA 72, reads as follows:"
29.5.1* Required Detection.
29.5.1.1* Where required by other governing laws, codes, or standards for a specific type of occupancy, approved single and multiple-station smoke alarms shall be
installed as follows:
(1)*In all sleeping rooms and guest rooms
(2)* Outside of each separate dwelling unit sleeping area, within 21 ft (6.4 m) of any door to a sleeping room, with the distance measured along a path of travel
(3) On every level of a dwelling unit, including basements
(4) On every level of a residential board and care occupancy (small facility), including basements and excluding crawl spaces and unfinished attics
(5)*In the living area(s) of a guest suite
(6) In the living area(s) of a residential board and care occupancy (small facility)
AGENCY PLACEMENT RECOMMENDATIONS
________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________
(Reprinted with permission from NFPA 72
, National Fire Alarm and Signaling Code Copyright © 2010 National Fire Protection Association, Quincy, MA 02269. This
®
reprinted material is not the complete and official position of the National Fire Protection Association, on the referenced subject which is represented only by the
standard in its entirety), (National Fire Alarm and Signaling Code
and NFPA 72
are registered trademarks of the National Fire Protection Association, Inc., Quincy,
®
®
MA 02269).
California State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A Smoke Alarm installed
in each separate sleeping area (in the vicinity, but outside bedrooms), and Heat or Smoke Alarms in the living rooms, dining rooms, bedrooms, kitchens, hallways,
finished attics, furnace rooms, closets, utility and storage rooms, basements, and attached garages.
AGENCY PLACEMENT RECOMMENDATIONS
NFPA 72 Chapter 29
"For your information, the National Fire Alarm and Signaling Code, NFPA 72, reads as follows:"
29.5.1* Required Detection.
29.5.1.1* Where required by other governing laws, codes, or standards for a specific type of occupancy, approved single and multiple-station smoke alarms shall be