Maxnet MNDC Installation & Operation Manual

Mnac/mndc modular power supply

Advertisement

D3.1 /
CCAP
®
Compliant
®
Pat. #s U.S. 6,842,348; 7,043,236;
Pat. #s U.S. 6,842,348; 7,043,236;
Cdn. 2,404,840; 2,404,844
Cdn. 2,404,840; 2,404,844
MNAC/MNDC Modular Power Supply
Installation & Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MNDC and is the answer not in the manual?

Questions and answers

Summary of Contents for Maxnet MNDC

  • Page 1 D3.1 / CCAP ™ ® Compliant ® Pat. #s U.S. 6,842,348; 7,043,236; Pat. #s U.S. 6,842,348; 7,043,236; Cdn. 2,404,840; 2,404,844 Cdn. 2,404,840; 2,404,844 MNAC/MNDC Modular Power Supply Installation & Operation Manual...
  • Page 2 Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice. SignalOn Series, MAXNET , HFC Enhance , PCI Filters , Q-Series &...
  • Page 3: Table Of Contents

    PRODUCT DESCRIPTION ........................1-1 1.1. Technical Specifications ........................1-1 1.2. Functional Diagrams.......................... 1-2 INSTALLATION ............................2-1 2.1. Product Inspection ..........................2-1 2.2. Module Installation into the Active MAXNET Chassis ..............2-1 ® 2.3. DC Redundant Powering of Active MAXNET Chassis ..............2-2 ®...
  • Page 4 Index of Figures & Tables Figures #1 MNDC Power Supply Functional Diagram ..............1-2 #2 MNAC-110 Power Supply Functional Diagram .............1-2 #3 MNAC-220 Power Supply Functional Diagram ............1-2 #4 MNAC-110CM Power Supply with Current Monitoring Functional Diagram ....1-2 #5 MNAC-220CM Power Supply with Current Monitoring Functional Diagram ....1-2 #6 MNRPS Remote Power Supply Functional Diagram ............1-2...
  • Page 5: Product Description

    Installing two power supply modules into the chassis will maintain power to the backplane in the event that one of them fails. Both the MNAC and the MNDC include a 24 VDC rear terminal block connection for the remote chassis powering options.
  • Page 6: Functional Diagrams

    CURRENT: 3.6 AMPS DC CURRENT: 3.6 AMPS DC MNRPS(CM) MNRPS Figure #6: MNRPS Remote Power Supply Figure #7: MNRPS(CM) Remote Power Supply Functional Diagram with Current Monitoring Functional Diagram MAXNET – MNAC/MNDC Modular Power Supply – Installation & Operation Manual ®...
  • Page 7: Installation

    MNAC’s IEC power inlet. If the power supply is an MNDC module, use bus wire to connect the -48 VDC to the terminal block on the back of module following the terminal block labeling (see Table 3 below). A disconnect device is required between the -48 VDC supply and the MNDC power supply.
  • Page 8: Dc Redundant Powering Of Active Maxnet ® Chassis

    +24 VDC to the Active MAXNET Chassis backplane. 2.6. Voltage Monitor The MNAC and MNDC power supply module have test ports on the front panel. By connecting a DVM between the Pos (RED) and Neg (Black) port, the chassis backplane +24 VDC level can be monitored. MAXNET –...
  • Page 9: Maintenance & Troubleshooting

    Check the GREEN Power LED on each Power Supply module. If one is off or intermittent, then the chassis is not getting correct power. Refer to the MNAC/MNDC Not Powering Chassis troubleshooting section. If power availability is not an issue and other modules in the chassis are okay, the module itself is suspect.
  • Page 10 CHAPTER 3: MAINTENANCE & TROUBLESHOOTING This page left intentionally blank. MAXNET – MNAC/MNDC Modular Power Supply – Installation & Operation Manual ®...
  • Page 11: Service & Support

    Grounding or Polarization: Precautions should be taken so that the grounding or polarization means of the device is not defeated. NOTE: When installing the MNAC or MNDC Power Supply, the GND bonding terminal #1 on the back of the MNAC or MNDC Power Supply shall be connected to the chassis ground lug.
  • Page 12 Power Supply Removal: Power (AC or DC) should be disconnected from the module before removing for replacement or service. This is accomplished by removing the AC IEC plug for the MNAC unit and wires from the terminal block of the MNDC unit.
  • Page 13 CHAPTER 4: SERVICE & SUPPORT This page left intentionally blank. MAXNET – MNAC/MNDC Modular Power Supply – Installation & Operation Manual ®...
  • Page 14 1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Tel +1 (905) 428-6068 Toll Free +1 (800) 565-7488 Fax +1 (905) 427-1964 Toll Free Fax +1 (866) 427-1964 www.atxnetworks.com support@atxnetworks.com Printed in Canada Rev. 04/17 (ANW0874)