Amperes LS4600 Instruction Manual

Speaker line surveillance
Hide thumbs Also See for LS4600:

Advertisement

INSTRUCTION MANUAL
LS4600
Speaker Line Surveillance
Thank you
for choosing another quality product from Amperes Electronics.
LS4600 was produced out of extensive research and development effort in which every aspect of line surveillance require-
ments are studied. It solves the problem faced by many installers using the conventional line monitoring method, by adopt-
ing impedance measurement methodology. This shall eliminate the needs to add coupling capacitors to every speakers,
rigid cabling rules as well as inaccuracy in detection. Thereby, LS4600 allows branching in cabling works, direct tapping of
line to speakers as well as easier setup, without having to trim impedance against a preset reference.
LS4600 is built and run by a micro-controller , thus providing a digital platform in setting up your system. User can
set various parameters by following the menu displayed in the LCD screen. Among them shall be the high and low limits,
buzzer on / off, display backlight, monitoring setup time, auto or manual mode as well as doing manual testing.
It shall not be difficult to understand or to install the unit, but it is recommended that a trained personnel is engaged in order
to tap the many features available. Before installation, we suggest a thorough read through of the manual is done to avoid
any unnecessary damage to your setup.
Please keep this manual handy for any future references.
VER 3 / 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS4600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Amperes LS4600

  • Page 1 LS4600 is built and run by a micro-controller , thus providing a digital platform in setting up your system. User can set various parameters by following the menu displayed in the LCD screen. Among them shall be the high and low limits, buzzer on / off, display backlight, monitoring setup time, auto or manual mode as well as doing manual testing.
  • Page 2: Parts Identifications

    7. RED FAULT LEDs Once lit, it indicates that the particular channel is at fault ; either open, short or leakage. Refer to the LCD panel for exact condition of fault. PAGE 2 LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE...
  • Page 3 LED. 9. 24V DC POWER SUPPLY PORT The unit requires 24V DC power supply and recommended PSU shall be Amperes PS9400. Only use regulated power supply if other than PS9400 is installed. 10. ZONE TRIGGER OUTPUT PORT When line monitoring is initiated either manually or auto, it shall start in sequence from ch.1 to 6.
  • Page 4 LS4600 have been improve all accuracy. It is recommended that periodical manual checking or setup to be made as connections may deteriorate over time and thus affecting overall impedance value.
  • Page 5: Connecting The Unit

    If a particular zone is active (zone on) but the volume controller at a certain area is shut off (eg. zone 1), activation of monitor- ing from LS4600 of zone 2 shall override the volume controllers at zone 1, thus a burst of audio shall be heard ( such as BGM being currently played).
  • Page 6: Setup Menu

    There are 2 modes of operation available : Basic and Advance. In Basic setup mode, LS4600 shall detect the circuit for Open and Short only. The timing of detection shall depend on the intervals set in Auto Detection mode, ( Refer to Auto Test section ). Follow the steps below to use this mode.
  • Page 7 The preselected values for high limit and low limits are from 00 ohm to 500 ohm, with incremental of 20 Ohms. We recommend 50 % higher or lower values to avoid unnecessary false triggering. Once the required value is selected, press ENTER to proceed to the next sub menu. LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE PAGE 7...
  • Page 8: Manual Test

    This menu enable the user to view the values of impedance of selected channels, which had been accepted earlier during setup (Menu 1.0). To clear the memories, use the MEMORY Menu (Menu 7.0) and all previously stored values and settings shall be erased. PAGE 8 LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE...
  • Page 9 For fault alert buzzer, if this is switch on, the Buzzer LED shall not lit when a failure is detected. If the buzzer is switched off, the buzzer LED and the correspondence channel fault LED shall lit. LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE PAGE 9...
  • Page 10: Lcd Backlight

    After completing all channel setting, the changed parameters MUST be saved. DC power to the unit can be switched off when system is not in use. Settings shall be retained in the memory. PAGE 10 LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE...
  • Page 11: Summary Of Features

    Dimensions (WxHxD) 482 x 44 x 180 mm Weight 2.3 kg Note: The above specifications are correct at time of printing but subjected to changes without prior notice due to product improvements. LS4600 | 6 CHANNEL SPEAKER LINE SURVEILLANCE PAGE 11...
  • Page 12: Warranty Conditions

    Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia or its authorized master distributor, TNT Links Sdn Bhd / MyPA Systems Sdn Bhd.