Page 1
Pantone 485 Red Pantone 123 Yellow Model R2050 Pantone 534 Blue Thermal Imager, 80 x 80 Pixels Black Only if you REALL Instruction Manual www.reedinstruments.com 1.800.561.8187 information@itm.com www. .com...
Instrument Description ..............7 Operating Instructions ..............8-13 Menus ..................13-26 Battery Instructions ..............27 For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com Blue - 100/80/30/5 4 Blue Yellow - 0/27/100/0...
Safety • To prevent eye damage and personal injury, do not look into the laser • Do not point laser directly at people or animals or indirectly off reflective surfaces • Do not disassemble or do modifications to the Thermal Imager •...
Specifications Imaging & Optical Data IR Resolution 80 × 80 (6400 pixels) Thermal Sensitivity / NETD < 0.1°C @ +30°C (+86°F) / 100 mK Field of View (FOV) / Min. Focus Distance 17°x 17°/ 0.5m Spatial Resolution (IFOV) 3.78mrad Image Frequency 50Hz Focus Mode Manual...
Page 6
Dimensions (L x W x H) 8.8 x 3 x 7.8" (224 x 77 x 96mm) Weight <500g with battery REED Instruments offers certified thermography training. Contact REED Instruments at info@reedinstruments.com for complete information, dates and locations. Blue - 100/80/30/5...
Operating Instructions Before you use the Thermal Imager for the first time, charge the battery for a minimum of 1.5 hours. To charge the battery, refer to the "Battery Instructions" section of this manual. Turning the Unit On and Off To turn the Thermal Imager on, push the Power button .
Page 9
D:S theoretical ( = 1/ IFOV theoretical) = 265:1 D:S measure ( = 1/ IFOV measure) is the spot size needed to provide an accurate temperature measure. Typically, D:S measure is 2 to 3 times smaller than D:S theoretical, which means the temperature measurement area of the target need to be 2 to 3 times larger than that determined by the calculated theoretical D:S.
Page 10
Focus To adjust focus the IR lens rotates clockwise or anti-clockwise. When the target comes into focus, it displays a sharper image. When the target moves out of focus, the thermal image becomes blurry. Note: Correct focus is important in all imaging applications. Correct focus makes sure that the infrared energy is correctly directed onto the pixels of the detector.
LED Light On the desktop, press the right button, the LED light is on. On the desktop, press the right button again, the LED light is off. Laser On the desktop, press the left button, the laser is on. On the desktop, press the left button again, the laser is off. Temperature Measurement All objects radiate infrared energy.
Page 12
Emissivity The correct emissivity value is important to make the most accurate temperature measurement. Emissivity of a surface can have a large effect on the temperatures that the Thermal Imager observes. Understanding the emissivity of the surface, may not always, allow you to obtain more accurate temperature measurements.
Reflective Temperature Using the offset factor, the reflection is calculated out due to low emis- sivity, thereby improving the accuracy of the temperature measurement. In most cases, the reflective temperature is identical to the ambient air temperature. Only when objects that strongly radiate a higher tempera- ture are in proximity of the object being measured, should the reflective temperature be determined and used.
Page 14
Main Menu Main Menu is the main interface of the Thermal Imager’s menus. It contains six items, including Measure, Emissivity, Image, Palette, Temperature Range, and Settings. Measure: Set the calculation and display of radiometric temperature measurement data related to the thermal images.
Page 15
Image Mode In main menu, press “up” and “down” button, highlight “Image”. Press “select” button, pop-up Image submenu which contains infrared image, visual image and fusion. Press “up” and “down” button, highlight the Image mode which you want to choose. Press “OK”...
Standard Palette In main menu, press “up” and “down” button, highlight “Palette”. Press “select” button, pop-up the palette submenu. It shows four choices of palette: Iron, Rainbow, Grey, Grey Inverted. Press “up” and “down” button, highlight the palette which you want to choose.
Page 17
Measurement Menu In main menu, highlight “Measure” and press “select” button, pop-up the Measure submenu which contains Spot, Hot, Cold. Spot: Measure the center point temperature Hot: Capture maximum temperature Cold: Capture minimum temperature Press “Select” to select Spot, Hot, Cold to open the corresponding point of the temperature measurement.
Page 18
Emissivity In Object parameter submenu, press “up” and “down” button, highlight “Emiss”, press “select” button, pop-up emissivity submenu. “Emiss” sets the object's emissivity, the range of values is 0.01 to 1.00. Reflective Temperature Reflective temperature is important for accurate radiometric temperature measurement.
Page 19
Temperature Ranges The temperature measurement ranges have “-20~150°C” and “0~350°C” to choose. The overlap temperature of the two ranges is more accurate to choose “-20~150°C”. In main menu, press “up” and “down” button, highlight “Range”. Press “select” button, popup temperature ranges submenu. Press “up”...
Page 20
Language In Settings submenu, press “up” and “down” button, highlight “Language”. Press “select” button, pop-up language submenu. Press “up”, “down”, “left” and “right” button, highlight the lan- guage which you want to choose. Press “OK” button to confirm, “Cancel” to exit without change. Temperature Unit In Settings submenu, press “up”...
Factory Settings 1. In Settings submenu, press “up” and “down” button, highlight “Factory Set”. 2. Press “select” button, pop-up “Factory Set” submenu. 3. Press “OK” to restore factory setting, “Cancel” to exit without change. Factory Settings of the Thermal Imager are as follow: Item Parameter Value...
Page 22
Set Time In Settings submenu, press “Up” and “Down” button, highlight “Set time”. Press “select” button, pop-up “Set time” submenu. Press “Left” and “Right” button, highlight the item which you want to choose. Press “Up” and “Down” button, modify the value of the selected item.
Page 23
Camera Menu Thermal Imager has photo and video functions. In photo function, the Im- ager can save thousands of images. Every image resolution is 1280*960, format is .jpg, and stores infrared data and visible data in an image. In video function, the Imager has .mp4 video capture for hours, and saves infrared data in .mp4 format.
Page 24
Files Browser In desktop, press “Files Browse” button, pop-up files Browser which displays images and videos saved on SD Memory Card. Open an Image Press “up”, “down”, “left” and “right” button, highlight an image which you want to select. Press “Open” button to open an image. Press “Up”...
Page 25
Delete a File or All Files Press “up”, “down”, “left” and “right” button, highlight the image or video which you want to select. Press “Option” button, pop-up “Option” submenu. Press “Up” and “Down” button, highlight “Delete”, Press “OK” button to delete the selected file.
HDMI Output The video output available in the Thermal Imager enables displaying the thermal image (not includes operator menu) on an external monitor or video recording device capable of managing HDMI systems. To connect the Thermal Imager, proceed as follows: Connect the Thermal Imager to the external HDMI monitor or recording device using the HDMI video cable provided.
Do not charge in hot or cold areas. When you charge in extreme temperature, battery capacity may be decreased. For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com...
Page 28
Notes _________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ Blue - 100/80/30/5 4 Blue Yellow - 0/27/100/0 3 Yellow reedinstruments Red - 10/100/100/5 5 Red Yellow - 0/27/100/0 3 Yellow 1.800.561.8187 information@itm.com Blue - 100/80/30/5...
Need help?
Do you have a question about the R2050 and is the answer not in the manual?